Introduction 1 Device description 2 SIMATIC RTLS Programming interface 3 Localization systems SIMATIC RTLS4083T Installation & Operation 4 Technical specifications 5 Approvals 6 Operating Instructions 03/2020 C79000-G8976-C527-03
Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.
Table of contents 1 Introduction...................................................................................................................................................5 2 Device description ........................................................................................................................................9 3 4 2.1 Characteristics .........................................................................................................................9 2.
Table of contents 4 SIMATIC RTLS4083T Operating Instructions, 03/2020, C79000-G8976-C527-03
Introduction 1 Purpose of the Operating Instructions This manual will assist you in mounting, connecting, and programming the programming interface of the SIMATIC RTLS4083T device. The configuration and the integration of the devices in a network are not described in these operating instructions.
Introduction Apart from news, there you will also find: ● Project information: Manuals, FAQs, downloads, application examples etc. ● Contacts, Technical Forum ● The option submitting a support query: (https://support.industry.siemens.com/My/us/en/) ● Our service offer: Right across our products and systems, we provide numerous services that support you in every phase of the life of your machine or system - from planning and implementation to commissioning, through to maintenance and modernization.
Introduction Recycling and disposal The products are low in harmful substances, can be recycled and meet the requirements of the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE). Do not dispose of the products at public disposal sites. For environmentally compliant recycling and disposal of your electronic waste, please contact a company certified for the disposal of electronic waste or your Siemens representative. Note the different national regulations.
Introduction 8 SIMATIC RTLS4083T Operating Instructions, 03/2020, C79000-G8976-C527-03
2 Device description 2.1 Characteristics SIMATIC RTLS4083T Characteristics Design ① Status indicators (LED) ② F1 function key ③ display General The transponder is a mobile device for localiza‐ tion in the RTLS localing system. It sends data to gateways to determine its position. The gate‐ ways transmit the data to the Locating Manag‐ er Server. 1 Information can be transmitted to the transpond‐ er via a programming interface on the Locating Manager and shown on the display.
Device description 2.3 LED status indicator, display & function key Article number 2.3 Charging cradle without power supply for 10 transponders 6GT2790-0DD10 Power supply device for charging cradle without power plug 6GT2790-0DD40 LED status indicator, display & function key The operating states of the gateways are indicated by the LEDs. The states can be off , on and flashing . Table 2-3 LED LED status indicator Meaning Flashes green briefly when the F1 function key has been pressed.
Device description 2.4 Dimension drawing Dimension drawing 2.4 ) 6,0$7,& 57/6 7 Figure 2-1 2.
Device description 2.
Programming interface 3.1 3 Overview Functionality of the programming interface The functionality of the programming interface is available for the following transponders: ● RTLS4083T ● RTLS4084T The programming interface of the transponder is a functionality supported by the Locating Manager. It enables external client applications to communicate with the transponder via the Locating Manager Server.
Programming interface 3.2 Communication via the programming interface ● Query the current text or code and the current "Themes" ● Indication of the status of the "Control keys" used 3.2 Communication via the programming interface General The communication of the programming interface is done via a WAMP-Router that is a component of the Locating Manager Server.
Programming interface 3.2 Communication via the programming interface Characteristics of the programming interface 3URJUDPPLQJ LQWHUIDFH 57/6 7 57/6 /RFDWLQJ 0DQDJHU 53& FDOO )RU H[DPSOH VHWBGLVSOD\BWKHPH 53& FDOO UHFHLYHG :DLW IRU DQVZHU &KHFN 53& FDOO 6HQG UHVSRQVH WR SURJUDPPLQJ LQWHUIDFH $QVZHU UHFHLYHG 6HQG TXHU\ WR 57/6 7 :DLW IRU HYHQW PHVVDJH 4XHU\ UHFHLYHG 3URFHVV TXHU\ :DLW IRU FRQILUPDWLRQ IURP WUDQVSRQGHU &RQILUPHG (YHQW PHVVDJH UHFHLYHG 6HQG HYHQW PHVVDJH WR SURJUD
Programming interface 3.3 RPC calls commands to be transmitted in the wireless network do not reach the transponder or reach it incompletely, no event message is generated in this case. If an RPC call sets a field form to a value that is already set, an event message is sent immediately. This happens during or very shortly after the RPC call. Event messages are sent when a situation is reached.
Programming interface 3.3 RPC calls Command "Get Version" This command queries the protocol version. The default value is 1. URI "agilion.wls.epaper. get_version" Parameter None Return value Consists of: Version of the protocol, type: UInt32 Command "Get Tags" This command queries a list of all configured transponders in the Locating Manager Server. URI "agilion.wls.epaper.
Programming interface 3.4 Event messages Command "Get Display Theme" This command outputs the current "theme" and the current texts and codes for a single transponder. Only completely transmitted texts are returned. If the current "ThemeID" is unknown, it has the return value -1. URI "agilion.wls.epaper.
Programming interface 3.5 Code examples "Button Pressed" event message This event message is sent after the F1 function key has been pressed or released. If you want to adapt the short/long press functionality, you need to change the parameter involved in the configuration file, "RTLS_LM_DataExport.ini". URI "agilion.wls.epaper.
Programming interface 3.5 Code examples Code example WAMP connection with RPC call console.log("start") var config = null function changetheme(session, addr, themeid, param){ console.log("change zone for etag (zoneid,etag)",themeid,addr) var epapercmd = [parseInt(addr,10),parseInt(themeid,10),param] if ( config.debug ) console.log("send epapercmd: ",epapercmd) session.call("agilion.wls.epaper.set_display_theme", epapercmd).then( function (res) { if ( config.debug ) console.
Programming interface 3.5 Code examples console.error(e) process.exit(1); } console.log("connect to wamp-router", config.wamp.name) var connection = new autobahn.Connection({ url: config.wamp.url, realm: config.wamp.realm, max_retries: 1, authmethods: ['wampcra'], authid: config.wamp.user, onchallenge: function (session, method, extra) { if (method === "wampcra") { return autobahn.auth_cra.sign(config.wamp.key, extra.challenge); } } }); connection.onopen = function (session) { console.
Programming interface 3.6 Additional information } } } ); }; //connection.onopen connection.onclose = function (reason, details) { console.log("no connection to wamp-router",config.wamp.name); } connection.open(); Code example RPC calls (pseudo code) //get_version RPC: agilion.wls.epaper.get_version [ ] -> In return value: [Version] //get_tags RPC: agilion.wls.epaper.get_tags [ ] -> In return value: [ [TransponderID, ProductID, "FirmwareVersion"] , TransponderID, ProductID, "FirmwareVersion"], ...
Programming interface 3.6 Additional information LINK: (https://wamp-proto.org/) LINK: (https://crossbar.io/docs/) LINK: (https://crossbar.io/autobahn/) LINK: (https://github.com/crossbario/autobahn-js) LINK: (https://github.
Programming interface 3.
Installation & Operation 4.1 4 Notes on installation Note Before you install the devices, read this section carefully to ensure trouble-free installation and commissioning. The devices can only be used in conjunction with the RTLS localization system. Mount the device so that it has a direct line-of-sight connection to the gateways (360° panorama view). Any type of material can impact wireless localization. Wireless localization through metal is not possible.
Installation & Operation 4.3 Cleaning and maintenance CAUTION Fires and burns Improper handling of the battery can lead to fire and skin injuries. The housing of the device must not be squashed, punctured or exposed to other mechanical influences. Never expose the device to fire, temperatures above 40 °C or direct sunlight for an extended period of time. 4.
Installation & Operation 4.4 Charging instructions 4.4 Charging instructions Note Fully charge the device upon receipt. Mount the charging station in a location with cool ambient temperature. The temperature of the device and the ambient temperature must not exceed 40 °C for the device to be charged. The higher the temperature, the longer it takes to charge the device. If the device exceeds 55 °C during charging, remove the device from the charging station.
Installation & Operation 4.
5 Technical specifications Table 5-1 Technical specifications of the transponder RTLS4083T 6GT2700-5DC03, 6GT2700-5DC13 6GT2700-5DC23, 6GT2700-5DC33 Product name SIMATIC RTLS4083T PULSE radio frequencies (localization) Wireless method IEEE 802.15.4-2015 HRP UWB Transmission speed 850 Kbps Operating frequency rated value 3993.6 MHz (UWB channel 2; CE, FCC) 6489.6 MHz (UWB channel 5; CE, FCC, IC, CMIIT) Bandwidth 499.2 MHz Frequency range 3100 MHz ... 4800 MHz (CE, FCC) 6000 MHz ...
Technical specifications 6GT2700-5DC03, 6GT2700-5DC13 6GT2700-5DC23, 6GT2700-5DC33 Ambient temperature ● During operation ● -10 ... +50 °C ● During storage ● -10 ... +50 °C ● During transport ● -10 ... +50 °C ● During display operation ● ● During charging ● +10 ... +40 °C 0 ...
6 Approvals You can find the current EU Declaration of Conformity for these products on the Internet at Siemens Industry Online Support. Link: (https://support.industry.siemens.
Approvals Article 3 (1) b) EMC ● ETSI EN 301 489-1 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 1: Common technical requirements ● ETSI EN 301 489-17 Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic compatibility for radio equipment and services - Part 17: Specific conditions for broadband data transmission systems ● ETSI EN 301 489-33 Electromagnetic compatibility and radio spectrum ma
Approvals FCC information Siemens SIMATIC RTLS4083T (MLFB 6GT2700-5DC13); FCC ID SCF4083T02 This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Approvals Déclaration d'exposition aux radiations (RSS-102) Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement non contrôlé. Cet équipement doit être installé et utilisé à distance minimum de 7 mm entre le radiateur et votre corps.