Correct use
The RFU620 interrogator (standard device) is an intelligent
SICK-IDpro sensor from the RFU62x product family.
,WLVXVHGIRUWKHDXWRPDWLFÀ[HGLGHQWLÀFDWLRQRIZLUH-
less-based data carriers on moving or stationary objects and
their management.
As a compact reading and writing unit, the RFU620 has an
integrated antenna. It processes all standard passive tran-
sponders in accordance with ISO-/IEC-18000-6C and EPC-
global UHF C1G2 in the regional UHF carrier frequency range.
Thanks to its intelligent process logic it can be used either as
a stand-alone solution or as part of a group in a network.
The RFU620 sends the read results to a higher-level comput-
er for further processing via its host interface. Or it receives
commands for data carrier management (write, read, etc.) via
this interface.
Correct use also includes compliance with all information
in these operating instructions and the supplementary
RFU62x RFID Interrogator (UHF) Technical Information, No.
8015930.
The RFU62x product family consists of 3 version series which
are distinguished by their functionality (including type of data
interface) and the design of the electrical connection:
 Ethernet version (RFU620-101xx), with heating for ambi-
ent temperatures as low as –40°C
 Serial version (RFU620-104xx)
 PoE version (RFU620-105xx), PoE = Power-over-Ethernet
Each series contains variants for regional assignment (place-
holder xx above, see type label on the device) of the operating
license and the carrier frequency range (for an overview -
see ´7HFKQLFDOVSHFLÀFDWLRQVH[FHUSWµSDJH).
In this document, the RFU620 interrogator is simply referred
to as the "RFU620", unless a clear distinction needs to be
made between variants.
About this document
These operating instructions apply to all variants of the
RFU620. They allow you to commission the RFU620 quickly
and easily in an ambient temperature range from 0°C to
+50°C and to achieve initial read results with transponders.
They describe the commissioning process for an application
with DQ RFU620, starting with its default setting. Device vari-
ant RFU620-10100 (Ethernet version, regional assignment:
Europe) is used as the basis for the examples given. The
CDB620 connection module is used, for example, for the
industrial-standard signal distribution of the RFU620. With
the exception of the electrical connection, other variants are
commissioned in the same way.
Supplementary and other applicable documents
More detailed information about mounting and electrical
installation as a stand-alone device is available in the
RFU62x RFID Interrogator (UHF) Technical Information, No.
8015930. This describes and presents:
 Optional mounting accessories (brackets)
 Measures for electrical installation of the RFU620-
101xx in an ambient temperature range from 0°C to
–40°C
 The suppression of ground potential equalization currents
in applications with widely distributed systems
 Pin assignments and lead color assignments of cables
 Electrical wiring plans for the CDB620-001 connection
module, based on the RFU620
 Reference list and license texts for open source software
XVHGLQWKHÀUPZDUH
2SHUDWLQJWKH5)8LQDÀHOGEXVZLWKOLQHWRSRORJ\
The optional incorporation of the RFU620 in the PROFIBUS
DP, PROFINET IO or EtherCAT
®
ÀHOGEXVLVGHVFULEHGLQWKHUHO-
evant operating instructions for the CDF600-21xx, -2200
RUÀHOGEXVPRGXOH- see “Sources for obtaining
DGGLWLRQDOLQIRUPDWLRQSDJHµ
,QIRUPDWLRQDERXWFRQÀJXUDWLRQFDQEHIRXQGLQWKHRQOLQH
KHOSIXQFWLRQRIWKH623$6(7FRQÀJXUDWLRQVRIWZDUH
The listed documents are available in PDF format on the SICK
product pages on the Internet: ZZZP\VLFNFRPHQUIX[
&') and &')
In order to view PDF documents on a PC, PDF visualization
software is required, e.g. Acrobat Reader (http://get.adobe.
com/reader).
Safety information
 This chapter concerns the safety of commissioning
personnel as well as operators of the system in which the
RFU620 is integrated.
 Read these instructions carefully before commissioning
the RFU620 in order to familiarize yourself with the
device and its functions. The operating instructions are
considered a part of the device and must be kept in an ac-
cessible location in the immediate vicinity of the RFU620
at all times!
 )RUFRXQWU\VSHFLÀFSDUWLFXODUVWRFRQVLGHUZKHQRSHUDWLQJ
the RFU620, - see ´2SHUDWLRQDOUHVWULFWLRQVSDJHµ
a DANGER
Health hazard as a result of high-frequency electromagnet-
ic radiation!
The RFU620-10x00 (region: Europe) is designed for operation
in accordance with ETSI EN 302208. During operation, the
human exposure regulations covered by EN 50364 must be
observed.
> ,QRUGHUWROLPLWKXPDQH[SRVXUHWRHOHFWURPDJQHWLFÀHOGV
suitable safety distances must be maintained during both
short-term and long-term work in the radiation range of the
antenna.
Minimum distances to be maintained between the anten-
na and the human body:
10 cm during long-term transmission and max. radiation
power of the antenna of 250 mW (24 dBm) as per ETSI.
The RFU620-10x01UHJLRQ86$&DQDGDVDWLVÀHVWKHOLPLW
values of the FCC for exposure to radiation in an uncontrolled
environment.
> During operation, a safety distance of at least 20 cm must
be maintained between the antenna and the human body.
 The following requirements must be met if the IP 67
enclosure rating is to be maintained during operation
(otherwise, the device will no longer meet the conditions
IRUDQ\VSHFLÀHG,3HQFORVXUHUDWLQJ
 The side cover of the USB socket/Micro-SD card slot
must be screwed tight to the device
 The SICK cables plugged into the M12 connections
must be screwed tight
 Electrical connections that are not being used (RFU620-
101[[PXVWEHÀWWHGZLWKSURWHFWLYHFDSVSOXJVWKDW
are screwed tight (as in the delivery condition)
The RFU620 must only be used for a short period without
a cover in order to insert or remove the memory card or
use the USB interface temporarily. During this time, protect
the device against moisture and dust.
 Opening the screws of the RFU620 housing will invalidate
any warranty claims against SICK AG. For further warranty
provisions, see the General Terms and Conditions of
SICK AG, e.g. on the delivery note of the RFU620.
 Data integrity:
SICK AG uses standardized data interfaces, such as stan-
dard IP technology, in its products. The emphasis here is
on the availability of products and their features. SICK AG
DOZD\VDVVXPHVWKDWWKHLQWHJULW\DQGWKHFRQÀGHQWLDOLW\RI
the data and rights which are affected by the use of these
products will be ensured by the customer. In all cases, ap-
propriate security measures, such as network separation,
ÀUHZDOOVYLUXVSURWHFWLRQDQGSDWFKPDQDJHPHQWPXVW
be taken by the customer on the basis of the situation in
question.
&RPPLVVLRQLQJDQGFRQÀJXUDWLRQ
Scope of delivery
 RFU620 in the version ordered (functionality/design of the
connection, regional assignment). Electrical connections
ÀWWHGZLWKSURWHFWLYHFDSVSOXJV5)8[[:LWKRXW
connecting cables (RFU620-101xx, -105xx) and brackets.
 Printed operating instructions:
Europe/USA/Canada: English (No. 8015928) and German
(No. 8015927)
Other language versions may be available in PDF format
on the RFU620 product page on the Internet:
ZZZP\VLFNFRPHQUIX[.
Step 1: Mounting and alignment
Equipment required
 2 x M6 or 4 x M5 screws for mounting the RFU620 on a
mounting device (bracket) provided by the customer. Screw
length is dependent on the mounting base (wall thickness
of the bracket).
When using an optional SICK bracket, the screws for
mounting the RFU620 on the bracket are included in the
scope of delivery of the bracket.
Mounting requirements
 The permissible ambient conditions for operating the
RFU620 must be observed, e.g. assigned region, ambient
temperature, ground potential (- see “Technical spec
LÀFDWLRQVH[FHUSWSDJHµ and “Step 2: Electrical
LQVWDOODWLRQSDJHµ)
 The device must be mounted using all 2 M6 or 4 M5
threaded mounting holes provided (- see ´'HYLFHOD\RXWµ
page 3).
 6WDEOHPRXQWLQJGHYLFHZLWKVXIÀFLHQWORDGEHDULQJFDSDFL-
ty and suitable dimensions for the RFU620.
Weight approx. 780 g (without cables).
Dimension drawing - see ´'HYLFHOD\RXWµSDJH
 No electrically conductive material between transponder
and RFU620.
Mounting the RFU620
1. Select a suitable mounting location for the RFU620.
The mounting location and position depend on the anten-
QDÀHOGRIWKH5)8DQGWKHWUDQVSRQGHUVXVHG
Optional: Attach the SICK mounting accessories ordered
separately (mounting kit 1, 2, 3, 4 or 5) to the RFU620;
see "Mounting" chapter in the RFU62x RFID Interroga
tor (UHF) Technical Information, No. 8015930.
RFID interrogator (UHF)
with internal antenna
Mid range
RFU620-101xx
RFU620-104xx
RFU620-105xx