Figure 13: Password Setting
6.3. Block Description
Main constituents of the system are:
I) Master Optical Unit (MOU)
The MOU is installed at the indoor location close to the BTSs. In the DL
path, the received RF signals from the BTSs are fed to the MOU, which
converts the RF signals to a stream of optical signals to be applied to the
optical fibers for transmission to the DBROUs installed at different
locations. The optical signals between MOU & each of the DBROUs are
propagated on two single mode fibers.
In the UL path, the optical signals received from each of the DBROUs are
converted back to the RF signals in the preset frequency bands for
application to the BTSs.
The connectivity between the MOU and the BTS is through low loss RF
coaxial cable via directional coupler. The type of directional coupler shall
depend on the loss between the BTS & the MOU.