Showline Offices Dallas 10911 Petal Street Dallas, TX 75238 Tel: +1 214-647-7880 Fax: +1 214-647-8030 Auckland 19-21 Kawana Street Northcote, Auckland 0627 New Zealand Tel: +64 9 481 0100 Fax: +64 9 481 0101 Asia Unit C, 14/F, Roxy Industrial Centre No. 41-49 Kwai Cheong Road Kwai Chung, N.T., Hong Kong Tel: +852 2796 9786 Fax: +852 2798 6545 Europe Rondweg zuid 85 Winterswijk 7102 JD The Netherlands Tel: +31 (0) 543-542516 www.philips.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual IMPORTANT INFORMATION Warnings and Notices When using electrical equipment, basic safety precautions should always be followed including the following: a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. b. Do not use outdoors. c. Do not mount near gas or electric heaters. d. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. e.
Installation & User’s Manual SL NITRO 510 LED STROBE Luminaire TABLE OF CONTENTS Showline Offices................................................................................................................................................................. 0 IMPORTANT INFORMATION Warnings and Notices......................................................................................................................................................... 1 Additional Resources for DMX512....................
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Strobe Rate DMX Timing Detail .............................................................................................................................................. Strobe Duration DMX Timing Detail ....................................................................................................................................... SL NITRO 510 LED STROBE Luminaire RDM Parameter IDs.....................................................
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual PREFACE 1. About this Manual The document provides installation and operation instructions for the following products: • SL NITRO 510 LED STROBE Luminaire Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be found on the product specification sheet.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual SL NITRO 510 LED STROBE LUMINAIRE OVERVIEW 1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual LCD Display / Menu System Edit a Preset Edit a Chase Home (menu settings) DMX512 Addressing Return to Main Screen LCD Display To rotate menu 180 degrees from current orientation, press and hold the two center buttons for 2 seconds.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual INSTALLATION AND SET UP 1. Power Requirements The SL NITRO 510 LED STROBE Luminaire operates on AC input voltages from 100 to 240 VAC. WARNING! This unit does not contain an ON/OFF switch. Always disconnect power input cable to completely remove power from unit when not in use. AC Power Operation When connected to an AC source, the unit operates on 100 to 240 volts AC (+/- 10%, auto-ranging).
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 2. Connecting Power Units can be powered in one of two ways: • Direct connection to a AC power source using an AC input cable. For wiring of AC input connector, refer to "Connecting SL NITRO 510 LED STROBE Luminaires to AC Power" on page 8. • Connection from the AC output of another SL NITRO 510 LED STROBE Luminaire. When using this method, it is very important not to connect any other type of equipment device.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual CAUTION: In the event the AC input cable of this luminaire is damaged, it must be replaced, by the user, with an approved cable through an Authorized Showline Dealer or Service Center. 3. Connecting to the DMX512 Network Basic DMX512 installation consists of connecting multiple SL NITRO 510 LED STROBE Luminaires together (up to 32 luminaires) in "daisy-chain" fashion.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 4. Mounting Luminaire SL NITRO 510 LED STROBE Luminaires are provided with the ability to hang via truss hooks, clamps, etc. (sold separately). Simply attach hook, clamp, etc. to the SL NITRO 510 LED STROBE Luminaire’s mounts in the provided M9 holes. It is recommended (and may be required by local and national safety codes) to use and install a safety cable (sold separately).
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Connecting Luminaires Top-to-Bottom Each SL NITRO 510 LED STROBE Luminaire includes two built-in Quick Connect slot and pin systems as illustrated in Figure 8. This allows a quick connection of units when stacked on top of each other. Up to twenty SL NITRO 510 LED STROBE Luminaires may be supported when connected using the Quick Connect system. Side View 1 Locking Mechanism Locking Mechanism Pin Step 1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Connecting Luminaires Side-to-Side Each SL NITRO 510 LED STROBE Luminaire ships with three Luminaire Connecting Pins as indicated in Figure 9. All three pins are used to connect two luminaires together linearly. Each fixture must be mounted using its own mounting hardware. The side-to-side pins are only to align the luminaires and do not provide hanging support.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Connecting Combined Luminaires Top-to-Bottom When combining units connected top-to-bottom, two SL NITRO 510 LED STROBE Luminaires are first connected end-to-end and then connected top-to-bottom with a single SL BAR 520 luminaire. Connecting Notes: WARNING! Do not exceed 10 rows of combined luminaires connected together top-to-bottom with a single hanging point.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual vent the spacing between the two SL NITRO 510 LED STROBE Luminaires from spreading apart at the center. Obtain and install: SL BAR 520 LED Luminaire See detail below SL NITRO 510 LED STROBE Luminaires SL NITRO 510 STROBE LED Luminaires Nut Bolt Lock Washer Flat Washer Note, hardware shown available from others. 1) One M10-1.5 x 25 mm Long, Hex Head Cap Bolt 2) One 10 mm Flat Washer 3) One 10 mm Split-Lock Washer 4) One M10-1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Connecting Combined Luminaires Side-to-Side When combining units connected side-to-side, all units connect using the same pin system and any combination can be created (refer to installation instructions and warnings contained in "Connecting Luminaires Side-to-Side" on page 12). • Each SL NITRO 510 LED STROBE Luminaire and SL BAR 520 RGBW Luminaire ships with three Luminaire Connecting Pins as indicated in Figure 9.
Installation & User’s Manual SL NITRO 510 LED STROBE Luminaire OPERATION AND PROGRAMMING 1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual .
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Step 6. Press the Check Mark button to save the preset. You will be asked to confirm your saving operation. Step 7. The preset is now saved and can be recalled via the menu or DMX. Effects Effects are chases stored values of the luminaire's LED settings that can be recalled via the menu system or DMX. There are 10 factory defined chases and eight user adjustable chases.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Anytime the fixture is locked, each PIN code will unlock all functions except the pertaining features assigned via the security level. Note: The Level 3 PIN will always unlock all functions. Table 4: Security Lock Levels Lock Level Level 1 Menu Functions Affected Edit Presets, Edit Chases, and Settings Menu Level 2 Settings Menu Level 3 All Use the Up and Down buttons to select security PIN codes.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 7: Factory Default Parameters Parameter Load Factory Description • No - no action. • Yes - restore to factory default menu settings. Settings/DMX DMX configuration options are available in the DMX menu. Use the Up and Down buttons to select parameters and the Left and Right buttons to assign the fixture's DMX settings. When finished, press the Check button to exit the menu level. The adjustable parameters are described in Table 8.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Status The Status screen displays the current value of the master intensity and LED zone of the fixture. Use the Up Down Left Right arrows to scroll through the different zones and view their levels. • The last Status item displayed shows the RDM UID and current Firmware Version. • Press the Check Mark button to exit the Status screen.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 4. Dimming Curve Selection Through the menu, you are able to select one of four dimming curves: • Linear Curve • PL_Curve • S_Curve • Square Curve Lumen Output PL_Curve * Lumen Output Linear Curve 0 DMX Value 0 DMX Value *PL Curve follows the dimming curve of Philips Selecon PL series LED luminaries.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 5. Master / Slave Operational Mode The Master / Slave Operational Mode allows one SL NITRO 510 LED STROBE Luminaire to act as the "Master" unit and all other connected units are controlled by this unit. When a unit is set to "Slave" mode, it will only listen to and follow any commands sent from a "Master" unit. Only one "Master" unit is allowed in this type of operation. To setup a master / slave network: Step 1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual DMX CONTROL This section contains information for operating the luminaire using one of the DMX control modes as set by the luminaire’s menu system: • "Single Channel Control Mode" (below) • "Three Channel Control Mode" (below) • "Four Channel Control Mode" on page 25 • "16-bit Control Mode" on page 25 • "Zone Mapping Mode" on page 26 For Menu options and detailed information, see "LCD Display and Menu System" on page 16.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 3. Four Channel Control Mode Table 13 provides DMX channel mapping of all DMX512 control values when the SL NITRO 510 LED STROBE Luminaire is in Four Channel DMX512 mode (as set by the luminaire’s menu system).
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 14: DMX Channel Mapping (16-bit Control Mode) Control channel operation. Set control channel value to desired action, hold value for at least 5 seconds, then turn to 0. Set control channel value to 0 without any scaling.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (Zone Mapping Mode) DMX Channel Parameter 1 Intensity - High Byte 2 Intensity - Low Byte Range DMX Range% Default - recommended console default values 0 - 65535 0 - 100% 0 Description 16-bit control for the intensity of the LED settings - 0 to 65535 (full) Controls strobe operation as follows: 3 Strobe Effects 0 - 255 0 - 100% 0 No Effect = DMX 0 - 5 (default) Ramp Up = DMX 6 - 42 Ramp Down = DM
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 15: DMX Channel Mapping (Zone Mapping Mode) 14 Zone 4 Intensity 0 - 255 0 - 100% 0 8-bit control of Zone 4 intensity 0 to 255 (full) 15 Zone 4 Strobe Duration 0 - 255 0 - 100% 0 "Strobe Duration DMX Timing Detail" on page 30 16 Zone 4 Strobe Rate 0 - 255 0 - 100% 0 "Strobe Rate DMX Timing Detail" on page 29.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 6. Strobe Rate DMX Timing Detail The chart below describes the Strobe Rate DMX parameters of the SL NITRO 510 LED STROBE Luminaire. Note: Continuous ON Mode illuminates all LEDs without strobing. This feature is activated when Strobe Rate and Strobe Duration are both set to DMX value 255.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 7. Strobe Duration DMX Timing Detail The chart below describes the Strobe Duration DMX parameters of the SL NITRO 510 LED STROBE Luminaire.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual 8. SL NITRO 510 LED STROBE Luminaire RDM Parameter IDs The following tables outline and describe all the RDM parameters IDs associated with SL NITRO 510 LED STROBE Luminaires.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 18: SL NITRO 510 LED STROBE Luminaire RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value ■ PRODUCT_DETAIL_ID_LIST 0x0070 ■ DEVICE_MODEL_DESCRIPTION 0x0080 ■ ■ Comment Implemented MANUFACTURER_LABEL 0x0081 ■ ■ ■ DEVICE_LABEL 0x0082 ■ ■ ■ FACTORY_DEFAULTS 0x0090 ■ LANGUAGE_CAPABILITIES 0x00A0 ■ ■ ■ LANGUAGE 0x00B0 ■ SOFTWARE_VERSION_LABEL 0x00C0 ■ BOOT_SOFTWARE_VERSION_ID 0x00C1 ■ BOO
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual Table 18: SL NITRO 510 LED STROBE Luminaire RDM Parameters IDs Get Allowed Set Allowed RDM Parameter IDs Value SELF_TEST_DESCRIPTION 0x1021 ■ CAPTURE_PRESET 0x1030 ■ PRESET_PLAYBACK 0x1031 ■ ■ Comment Implemented Table 19: SL NITRO 510 LED STROBE Luminaire RDM Manufacturer Status IDs Manufacturer Specific messages are in the range of 0x8000 - 0xFFDF.
Installation & User’s Manual SL NITRO 510 LED STROBE Luminaire CLEANING AND CARE WARNING! All cleaning should be performed with power completely removed from the luminaire. Never remove protective covers when luminaire is powered. Wear appropriate protective eye wear and gloves when cleaning the fixture. All service and maintenance, other than described herein, should be performed by a qualified technician or Authorized Service Center. 1.
SL NITRO 510 LED STROBE Luminaire Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. SL NITRO 510 LED STROBE Luminaire Operational Specifications Source: Beam Angle: Light Output: Color Temperature: Input Voltage (AC): Current (AC): Frequency: Control Protocols: Ambient Temperature: Humidity: Cooling: Weight: Housing: Compliance: IP Rating: High Intensity White LED Array (x1350) 120 Degrees > 68,000 lumens 6500K 100V to 240V (+/- 10%, auto-ranging) 3.6 Amps (100V) / 1.