FCC ID: OPO199909010003 System Operation Manual of SHINKO Communication unit CMC K44-2127 Revision 0 Nov. 2, 2000 The information furnished herein by SHINKO ELECTRIC CO., LTD. is proprietary and confidential to SHINKO ELECTRIC CO., LTD. personnel and is not to be duplicated, published, or disclosed to any third party in whole or in part without permission from SHINKO ELECTRIC CO., LTD. SHINKO ELECTRIC CO.,LTD K44-2127 Rev.
FCC ID: OPO199909010003 Copyright © 2000 SHINKO ELECTRIC CO., LTD. ALL RIGHTS RESERVED. Unpublished rights reserved under the copyright laws of the United States. The information contained herein is provided pursuant to the terms of a License, Nondisclosure and/or Confidentiality Agreement and constitutes and contains valuable proprietary information and trade secrets of SHINKO ELECTRIC CO., LTD., embodying substantial creative efforts and confidential information, ideas, and expressions.
FCC ID: OPO199909010003 Revision Note # Revision #1 Rev.0 Month/Day/Year November. 2, 2000 SHINKO ELECTRIC CO.,LTD K44-2127 Contents Author The first edition Mitsuyoshi KURODA Rev.
FCC ID: OPO199909010003 Contents 1. 2. Introduction ______________________________________________________________ ______________________________________________________________1 ______________________________1 1.1. Construction of the documents _____________________________________________ _____________________________________________ 1 1.2. Application _______________________________________________________________ _______________________________________________________________ 1 1.3.
FCC ID: OPO199909010003 Introduction 1. Introduction 1.1. Construction of the documents The documents of the communication units CMC are as follows. Kind of document Operation manual Name of the document Communication unit CMC Operation Manual # of documents K44-2127 1.2. Application This document describes the operation of communication unit for transport system, OHT, OHS, etc. 1.3. Related Rules, Laws (1) FCC Part15 Subpart C 1.4.
FCC ID: OPO199909010003 Safety 2. Safety 2.1. Alert Boxes 2.1.1.General (1) Read and understand fully this manual and attached documents before operating the products. (2) Engage specialists in electrical and mechanical works. (3) Don’t improve the product by yourselves. (4) Be sufficiently proficient with the equipment, the relevant safety knowledge and the precautions prior to using this product.
FCC ID: OPO199909010003 Safety 2.1.3.Precautions on use DANGER Follow the following advice strictly to avoid electric shock or burns. 1. Don’t enter the operation area of the vehicle. Work on the ladder may collide to the vehicle and may cause injury. 2. Don’t touch the vehicle on the track when Power Supply Panel output the power. 3. Don’t touch the moving parts of the vehicle while it is in operation. Doing so may cause injuries. 4.
FCC ID: OPO199909010003 Safety 2.1.4.Storage PROHIBITION 1. Don’t store the equipment at locations where it is subject to rain, ater hazardous gas or liquid. MANDATORY ACTION 1. Store the equipment at locations in not subjected to sunshine. Store it at predetermined relative humidity and temperature. 0 degrees C. 50 degrees C., 90% RH and below, no dew. 2.1.5.Installation WARNING 1. Don’t climb on top of the equipment or place heavy items on it. Doing so may cause injuries. 2.
FCC ID: OPO199909010003 Safety 2.1.6.Maintenance and Inspection PROHIBITION 1. Don’t engage non-specialist technicians to disassemble and repair the equipment. DANGER 1. Before servicing CMC-BC,CMC-BM,CMC-TR,always shut off the power supply. If the communication signals are overlaid onto the non-conductive power line, also shut off the power source of the non-conductive power line before starting maintenance on CMC-BM and CMC-TR. Not doing so may cause electric shock. SHINKO ELECTRIC CO.
FCC ID: OPO199909010003 Outline 3. Outline of Communication Unit CMC 3.1. Overview The communication unit CMC (Communication Modem Controller) is used for the communication between the ground Vehicle Controller and several vehicles in the conveyance system made by Shinko Electric Co., Ltd. The communication signals are overlaid onto the power line for non-conductive power supply to the vehicles. In some systems, a separate signal lines may be used. CMC meet the requirements of FCC Part15 Subpart C.
FCC ID: OPO199909010003 Outline Power Supply Line (Parallel Wire) TX CMC-TR CMCBM Digital Signal line with shield RX Modem TX PCB BV-BM2 RX CPU PCB NBV-BC Vehicle Analog Signal line with shield Track CMC-BC Digital Signal line with shield Power Supply Unit Vehicle Controller Power Supply Panel Fig.
FCC ID: OPO199909010003 Outline CMC-TR CMCBM TX PCB BV-BM2 RX CMC-BM CMC-TR TX PCB BV-BM2 Output: 8-Port maximum RX PCB NBV-BC CMC-TR CMC-BM CMC-BC TX Digital Signal line with shield Digital Signal line with shield PCB BV-BM2 RX Power Supply Line (Parallel Wire) Analog Signal line with shield CMC-TR CMC-BM Digital Signal line with shield TX TX PCB BV-BM2 RX RX Output: 8-Port maximum Modem Analog Signal line with shield PCB Track NBV-BC CPU CMC-BC Vehicle Digital Signal line wit
FCC ID: OPO199909010003 Outline 3.3. Function of each unit 3.3.1.CMC-BC (Communication Modem Controller :Base Controller) This is an interface unit to handle the signals from/to the Vehicle controller. It also serves as the multiplexer for several CMC-BM units. CMC-BC can work in two different modes, master mode and slave mode. It allows the user to use the multiple units according to the scale of the conveyance system. The CMC-BC unit may vary in its outward form depending on the conveyance system.
FCC ID: OPO199909010003 Outline FCC ID:OPO199909010001 FCC ID: OPO199909010003 Block diagram To track CMC-BC CMC-BM (Communication Modem Controller-Base Controller) (Communication Modem Controller-Base Modem) CMC-TR CMC-BC (Slave) (Communication Modem Controller-TRansfoemer) BV-BM2 PCB Line transciver Resonance circuit TX Amp Modulater Master/Slave I/F Control logic Squelch X'tal OSC 24MHz Demodulater +5V Power Supply DC5V N12V Control logic 0V +5V Serial I/F RS232C / RS485 RX fi
FCC ID: OPO199909010003 Outline The Power LED Fig. 5 Outward form of the CMC-BC’s main printed circuit board NBV-BC Fig. 6 For example the outward form of the CMC-BC unit SHINKO ELECTRIC CO.,LTD K44-2127 Rev.
FCC ID: OPO199909010003 Outline The Power LED Fig. 7 The outline form of the CMC-BM’s main printed circuit board BV-BM2 SHINKO ELECTRIC CO.,LTD K44-2127 Rev.
FCC ID: OPO199909010003 Outline Fig. 8 For example the outline form of the CMC-BM unit Fig. 9 The outer forms of the transformers SHINKO ELECTRIC CO.,LTD K44-2127 Rev.
FCC ID: OPO199909010003 Outline 3.4. FCC standard The transmission assembly in the communication unit CMC meets FCC Part15 Subpart C as the intentional radiator. FCC ID of CMC:OPO199909010003 [Note.1] The FCC certificate position may vary because different case materials and shapes are adopted for different customers. NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
FCC ID: OPO199909010003 Specification 4. Specification Communication speed: Communication method: Vehicle controller− Vehicle 19.2 kBPS FSK (MAX 38.4 kBPS) 4.1. CMC-BC Unit name Manufacturer Weight Size Power consumption Input 1 Input 2 Output 1 Output 2 Output 3 CMC-BC SHINKO ELECTRIC CO., LTD. Approx.
FCC ID: OPO199909010003 Error Process 5. Error process [Note.1] Before servicing CMC-BC,CMC-BM,CMC-TR,always shut off the power supply. [Note.2] If the communication signals are overlaid onto the non-conductive power line, also shut off the power source of the non-conductive power line before starting maintenance on CMCBM and CMC-TR.