STM-7100™ User Guide Shinheung Precision Co.,Ltd.
User Guide& Copyright The information in this document is provided “as is” without warranty of any kind, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose, and is subject to change without notice for improvement of the product. Shinheung Precision makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Caution 1 ). Fully be aware of User Guide and Safety directions before use your product. 2). Only use included or recommended accessories. Shinheung Precision Company is not responsible for using not authorized accessories. 3). Stay away your eyes from Bar-code reader. 4). Turn off your terminal before removing the battery. 5). Do not attempt to disassemble or modify your product. It can cause fire, injury, electric shock and other damages to you and your product. 6).
Contents 1. Basic Unit -------------------------------------------------------------------------------------------------- 8 Parts Name --------------------------------------------------------------------------------------------------------- 8 Using the Stylus -------------------------------------------------------------------------------------------------- 11 Reset ------------------------------------------------------------------------------------------------------------- 12 2.
ActiveSync ------------------------------------------------------------------------------------------------------- 45 Reset -------------------------------------------------------------------------------------------------------------- 46 Fundamental Problems --------------------------------------------------------------------------------------- 46 Appendix A.
1.
Introduction This chapter explains you each parts of STM-7100.
MSR UP Button Down Button Battery Cap Left Side Paper check Window Paper Open Button Scanner Button Feed Button Right Side -8-
Hand strap Holder Battery Locker Battery Cover Camera Speaker Bottom Side DC Connector 24Pin Connector USB port Top side -9- Headset Jack Scanner
Using Stylus We provide a stylus for selecting items and entering information on the screen. 3 Functions you can use with Stylus Tap Touch the screen once with the stylus for selecting or open items Drag To move the text or images on the screen, you can drag with the stylus. You can select several items also. Tap and hold To see the available actions for the items, you can tap and hold the item with stylus. Once you see the pop-up menu, you can select the action that you want.
applications will be closed. It is same as the reset of Desktop PC. This is the Reset function. Before HARD RESET, you should try RESET to recover your device. Do not try HARD RESET indiscreetly. HARD RESET does not delete files and documents in FileBox folder. Back up important data to FileBox folder. When FileBox folder is full, you can buy additional SD/MMC Cards for back-up. .
2.
Starting This chapter explains you basic functions of STM-7100. When you turn on the unit, basic screen will be displayed. Functions of Icons in the basic screen are explained as bellows. You need to install the ActiveSync program for connecting this unit to the Computers. Please refer the “Connect to the PC” pages for installation and how to use of ActiveSync. ▶ Screen Icon Like PC Windows, you can see the Task bar on the lower part of the main screen.
Number Description ① Start button ② Start Menu ③ Current running program display ④ Connection to the PC (Active Sync)/ WLAN On/Off status ⑤ Hidden menu move ⑥ Time ⑦ keyboard ⑧ Switch the programs ▶ Switch the programs If you want to swich programs that are running, you can use the “Switch the programs” menu. When you select the programs that you want to switch, the selected program comes to the front.
Select the icon that you want. Selected program appear to the front side ▶ Text input with Input panel To input the information on the certain application, you can use the input panel. You can input the text via Keyboard or writing. If you tab the arrow besides of input panel, you can choose the input way Keyboard input or writing input.
① Select the Keyboard after tab the arrow just besides of input panel. ② Input the Key with stylus on the Keyboard ▶ How to use WLAN From the Start menu, run Internet Connector to connect with network through WLAN. Then you can use internet explorer to browse the internet.
3.
Connect to the PC Microsoft ActiveSync Installation and establish the partnersip. Using Microsoft ActiveSync, you can synchronize the information on your personal computer with information on your IMP-600. Synchronization compares the data on your PDA with your personal computer and updates both devices with the most recent information To establish a partnership with a PC, you need to install Microsoft ActiveSync on your PC. You can download ActiveSync at www.microsoft.com/korea ▶ ActiveSync Installation.
④ ActiveSync installation is finished. Please turn on and put the STM7100 unit to the cradle with USB cable connected to the PC. We will start the drive installation. ▶ Driver Installation ① After you connect this unit to the PC, Select List or specific location installation and click Next on the New H/W explorer Wizard.
③ Click Next ④ If you click Finish, driver installation will be finished. Once you finish installing drivers, it is ready to synchronize the unit and PC via ActivSync.
▶ Synchrozing the Unit and PC with ActiveSync ③ ① When you run ActiveSync, you can see the below screen. Click Next. ② Set up the partnership screen, select Yes and click Next. Next screen is for setting up how many PC you want to set the partnership. If you want one computer, please select Yes. If not, select No. and Click Next.
⑤ Establish a partnership is finished. Click Finish.
※ You need to change the partnership name when you hard reset the unit. In this case, Select the device name under File> Mobile Device and delete partnership name under File> Delete Partnership. Select Device Delete partnership If you have problems when you install Activesync, Please check the connection setting under File menu on the PC ActiveSync screen.. ▶ Synchronizing the data Synchronizing means updating the latest information after compare the information between the unit and PC.
1) Backup/ Restore files with ActiveSync You can back up or restore files, Data base, PIMS information and programs on the RAM to the PC. It can run automatically or manually. ▷ Backup 1) Connect the unit to the PC 2) If you select the Backup/Restore under Tool menu on the Activesync scree. 3) Select ‘Full Backup’ or ‘Incremental Backup. 4) Select the Backup now button, and you can see the following screen. Notice: Don’t remove the USB cable or run other process during Backup process.
② Connect the unit to the PC ③ If this program has Setup.exe or Install.exe, double click this file on the PC. And this installation files will be copied to the unit automatically. ▷ *.cab ① Download the programs or insert the program CD to the PC. ② Connect the unit to the PC ③ Copy the *.cab file and paste to the My documents/Programs Files folder on the Mobile Device windows which generated by selecting Explore button of PC ActiveSync.
4.
Shell and File Explorer Shell No.
* Program: basic program * Favorites: Saved user selected favorites * Documents : Files in the My Documents * Setting : Setting for STM7100 * Run : Program running - Switch Program : Showing current running program and you can select the programs that you want.
- Status Icon : Showing the STM-7100™ device and application status. You can see ( )button on the left side if the number of icons are over the limited number. If you click this button, you can see the icons that are not showing. 2. File Explorer File Explorer has same functions as PC file Explorer.
5.
Device setting and Optimizing Let’s check the control panel.
Connecting through Serial ports Display Wall paper Back (can change it manually) light control (can adjust Backlight option) Brightness - 32 -
Volume & Sound - Change Configuration & save (Can change setting of sounds, to hear selected sound) Scanner Can test scanner and fix option for Test - 33 -
Stylus When stylus does not operate correctly, you can tap Re-Align to revise the coordinates System Property - 34 -
Basic system information Storage memory & Program memory setting - 35 -
Storage management Storage management (SD/MMC formatting) Format Storage (Filebox Micro SD formatting) WARRNING: When the user format the system, all of users data is to removed To Divide FileBox - 36 -
- 37 -
Option is needless to change. Tap Start to start formating. Check 'Quick format' to format quickly.
Tap Mount. (Otherwise, you cannot see it in File explorer.
Printer Setting Test Program to check printer status.
MSR Property Card Reader Test Process Read the magnetic stripe of a card to the end of it. Any direction is OK.
Memory You can use two kinds of memory for IMP-600(Built-in RAM and Micro SD Card). 1) Built-in RAM(Random-Access Memory) RAM is volatile memory divided into Storage memory and Program memory and OS assigns the proportion. But, OS may not control memories in case there's not enough memory space. If you encounter the message Storage or Program memory shortage, follow directions below. How to free Storage memory? - Move needless files and programs to Web folder.
Micro SD Card is a small and removable flash memory that allows you to store more data. You can backup important data and transfer big-sized data to other devices. Micro SD Card is available in many electronic product shops.
6. Trouble Shooting--------------------------------------------------------------- 45 ActiveSync ------------------------------------------------------------ 45 Reset ----------------------------------------- 46 Fundamental Problems -------------------------------------------------------- 46 Appendix A.
Troubleshooting Check the following guide for the possible cause of a problem and how to correct it. For more detail or other problems, visit our website (www.wjst.co.kr) ActiveSync Check following guide for problems when the device is connecting to PC. Other problems concerning update issues see Help of ActiveSync on your PC or visit Microsoft mobile device web site www.microsoft.com/windows/embedded/ce.
data will be saved. Resetting 1. Remove Micro SD card if it is mounted 2. When the power is on, press the ‘RESET’ button with the stylus, then release Notice : Do not reset while you are wearing Ear micro phone, it may cause serious damage to your ear. Information : If the function cannot be restored even if the reset button is pressed, initialize your device. Initializing (Hard Reset) When you initialize your device, it returns to the status when it was purchased.
the default setting. Fundamental Problems Q1. The power button is pressed but the power does not turn on The built-in battery is exhausted. Please charge the battery Q2. Even if the built-in battery is completely charged, it discharges after a short period of time. Set the power management start > setting > display > lighting start > setting > brightness start > setting > power > battery (set idling condition) For more detail, see chapter 8 ‘Device setting and optimizing’ Q3.
Q5. I want to check data in Micro SD card. Open ‘File Explorer’ and mount Micro SD card. Then ‘Storage Card’ folder is formed.
Additional information Usage and Maintenance For prolonged use of device, please follow the instructions below. - Device Cleaning Utilize soft dry cloth for cleaning. Chemical cleaning solution can damage the device external housing - Touch screen Cleaning Before cleaning, turn-off the device. Utilize soft dry cloth with conventional window cleaning liquid to clean. Do not directly spray the cleaning liquid over the touch screen.
- Always use stylus that provided with the STM7100 device Avoiding Electrical Interference STM-7100 can be affected by Electrical Interference from other devices. To avoid such case, one can change the device location and/or distance of between/among other devices. - Avoiding High Temperature STM7100 is designed to operate properly between 0~40 Celsius (32~104 Fahrenheit).
OS version : Microsoft Windows CE.net 5.0 Memory : 32MB NOR , 64MB NAND (up to 256) / 64MB SDRAM (up to 128) LCD Screen : 320x240, 3.5” 260K color TFT-LCD with Touch Screen Wireless Communications: 802.
Body-worn Operation This device was tested for typical body-worn operations with the back of the device kept 0 cm between the user’s body and the back of the device. To comply with FCC RF exposure requirements, a minimum separation distance of 0 cm must be maintained between the user’s body and the back of the device. Third-party belt-clips, holsters, and similar accessories containing metallic components may not be used.