TH10A-MDF-019 Infrared thermometer User Manual Mode:TH10A Shenzhen Yolanda Technology Co., Ltd.
Introduction Thank you for choosing the infrared thermometer of Shenzhen Yolanda Technology Co., Ltd.. With the unique technology, the infrared thermometer TH10A of Yolanda can give the result of stable measurement. The product will self-test every time when it starts up to make sure the normal operation and accuracy.
Table of Contents 1. Product Overview .............................................................................................................4 2.Warning instructions and precautions ..............................................................................5 3.Symbol description ..............................................................................................................5 4. Safety Precautions........................................................................................
1. Product Overview Thank you for choosing our Infrared Thermometer. The TH10A Infrared Thermometer is used to measure objects temperature based on the relationship between temperature and measurable infrared radiation. Simply aim the unit’s probe at the surface of objects to obtain a quick and accurate temperature. To ensure proper use, please be sure to read this user manual carefully, paying close attention to the safety precautions.
2.Warning instructions and precautions The warning signs and graphic symbols in the manual are intended to enable you to use the product safely and correctly and to prevent harm to you and others.Warning marks and graphic symbols are described as follows: Warning/precautions symbols Waring caution Notes Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Means a possibility of personal injury or property damage in case of improper use.
4. Safety Precautions Warnings - Please put the Thermometer out of children reach. - Do not take readings less than half an hour after a meal, exercise, a bath, take medicine or time spent in a particularly hot or cold environment. - Do not measure the sites of scarred tissue or tissue compromised by skin disorders, because sensing body temperature from sites of scarred tissue or tissue compromised by skin disorders may be not correct.
- Lay persons shall be note that the use of this thermometer is not intended as a substitute for consultation with your physician. It is dangerous for user to perform a self-evaluation and selftreatment based on the measuring results, consult your doctor if you suspect a fever. - As ear wax can affect the measurement, you should clean the ear before measuring ear temperature. - The thermometer may be used by children only under adult supervision.
- Check the sensor before use If have pollution and spray, please clean it. If the lens is damaged, please stop using. - Before using, please check if the thermometer appearance is intact, if measurement function is normal. if there any abnormal, stop using. - Forehead temperature measurement: Depending on various skin types and thickness, there may be temperature difference in forehead temperature measurement. 5. Description of the TH10A 5.
No. Name No. Name ① LCD ⑥ Probe ② Measuring button ⑦ Ear/forehead mode switch ③ Mode button ⑧ Battery cover ④ Memory button ⑨ Unit switch button ⑤ Forehead cap ⑩ Battery compartment 5.
① 12Y-up mode ⑦ Temperature unit: Fahrenheit ② Calibration mode ⑧ Mute icon ③ Ear mode ⑨ Memory group number ④ Bluetooth symbol ⑩ Memory icon ⑤ Battery symbol ⑪ Temperature valuable ⑥ Temperature unit: Celsius ⑫ 12Y-down mode 6. Specifications Device name Infrared thermometer Model TH10A Measurement mode Ear mode, Forehead mode; Both the forehead and ear mode is adjusted mode Both the forehead and ear mode include the submode of 12Y-down mode and 12Y-up mode.
temperature. Clinical bias (△cb)of ear and ±0.1℃ (±0.2℉) forehead mode Limited of agreement (LA)of ear and forehead mode (Calculate according to ISO 80601-2-56-2017+A1:2018) Clinical repeatability ±0.3℃ (±0.5℉) Measurement range For ear and forehead mode: 32.0℃ (89.6℉)~ <2.0℃ (<0.4℉) (Calculate according to ISO 80601-2-56-2017+A1:2018) 43.0℃(109.4℉) (for lab. condition) For ear and forehead mode: ±0.2℃(±0.4℉): 35.0℃(95.0℉)~42.0℃(107.6℉); ± 0.3 ℃ ( ± 0.5 ℉ ): 32.0 ℃ (89.6 ℉ )~34.9(94.8 ℉ ); 42.
Software version Embedded software version of TH10A:V1.0.0 Bluetooth APP version: 1.0.1 Note: Not intended to be sterilized. Not for use in an OXYGEN RICH ENVIRONMENT Remark: 12Y-down mode is designed to measure the body temperature of people aged 12 and below, 12Y-up mode is designed to measure the body temperature of people over 12 years old.
Bluetooth 5.1 Valid Transmission Up to 10 meters Receiver Smart phones with Bluetooth 4.0 or above version, and, Smart phones running Android 6.0 and iOS 10 or above system Signal transmission 2.4G Bluetooth Frequency 2.402-2.480 GHz Output power MAX +6dBm 7.2 Wireless Security The Bluetooth App database include a Hash algorithm to protect data. Bluetooth Connections include Smart (low energy) Bluetooth protocol 5.1.
Possible effects from RF sources in the vicinity of the device When using infrared thermometer with a smart device, relocate the devices away from sources that may interfere with the Bluetooth. The presence of other devices that may create radio frequency interference (RFI) may result in loss of Quality of Service of the Bluetooth connection.
Notes: ● The two batteries supplied with the product can ensure the power consumption for at least 1000 times temperature measurements. ● When changing the batteries, use batteries of the same type and capacity. ● Always replace all batteries at the same time. ● Battery polarities should be correctly installed. The polarities are mark on the battery compartment. ● Please remove the batteries if the thermometer will not be used for a long time(over 3 months). 9 Instruction for use 9.
Make sure that the probe and the ear canal are clean. As the ear canal is slightly curved, please pull the ear slightly backwards before inserting the probe.This is important so that the probe can be pointed directly at the eardrum. 4) Press the “ ” button for 1second then release the button,about 1 second later, the measured value will be appeared on the display with a “bi---” sound (If the buzzer sound is turned on).
Been exposed to very hot or very cold temperatures, or Been recently swimming or bathing In these cases, remove the individual from the situation and wait 30 minutes prior to taking a temperature. - Do not remove the thermometer out of the ear canal until you hear beep at the end of the measurement. - This thermometer may only be used without a disposable protective cover when measuring the ear temperature.
3) Aim measuring head with the forehead cap towards the middle part of forehead, make sure that the distance between probe tip and forehead is 1~3cm. Press the “ ” button for about 1 seconds then release the button, about 1 second later, the measured value will appears on the display with a “bi---” sound(If the buzzer sound is turned on). 4) Take off the device for reading the result.
- Do not use 12Y-up mode to measure the body temperature of people aged 12 and below, Do not use 12Y-down mode to measure the body temperature of people over 12 years old, otherwise the measurement results may be slightly biased. Notes: - Before measuring forehead, make sure there is no hair, sweat, cosmetic, perspiration or hat on it. - It is normal that there may be temperature difference depending on various skin types, since different skin type will reflect different voltage of infrared ray.
This device stores the last 9 sets temperature measurements. If you want to get memory data, please following the below to get it. 1) At turning on status, press the“ ” button, to enter the memory query mode and the LCD will display the memory icon and first group of measurement data . 2) press the“ ” button repeatedly to switch a series of measurement data, memory number will start from 1, 2,3,... .
10. Wireless transmission function operation guide 10.1 APP Download and Installation If you want to use the Bluetooth function, you can download the free App from the Apple App Store and Google Play: --- For iPhone with iOS 10 or above system, enter the “Runcobo note” under Apple APP store, then search and install the Bluetooth APP. --- For Android phones with Android 6.0 or above, enter the “Runcobo note” under Google Play, then search and install the Bluetooth APP.
Fig. 1 Fig. 2 Reset password If you forget your password, you can reset the password by doing the following: 1) In the login interface (Fig.1),click “forgot password”, then it will jump to Fig. 3 interface. 2) Enter your email address(i.e. the user account), then click the “get verification code”, the verification code will send to your email. 3) Log in to your email to check the verification code and fill the verification code in the verification code box.
Fig. 3 Fig.4 10.2 Binding of APP and you thermometer If this is your first time to use the Bluetooth APP function ,you shall binding the APP and you thermometer: 1) Turn on your phone's Bluetooth function. 2) Click the Bluetooth App icon on your smart phone, the APP will jump to the Fig. 1 interface, enter your account number and password, the click “login”, the APP will jump to the Fig.5 interface. 3) Click “Click Add thermometer” on Fig.5, it will jump to Fig.
Fig.5 4) 5) 6) Fig.6 At this time, please follow the interface prompt of Fig.6, press the “ ”button on your thermometer to start up and measure temperature until the temperature value is displayed on the thermometer, then app can successfully search your thermometer. When the app searches for your thermometer, the APP will display as Fig.7. Click the “Waiting for binding” on Fig.7 interface, it will jump to Fig.
mobile phones may eject different contents. Please don't care. You don't need to click. It won't affect the pairing of Bluetooth and thermometer. Fig.7 Fig.8 Fig.9 Pairing code displayed by LCD 7) At the Fig.10 interface, fill in the six-digit pairing code shown on the thermometer's LCD. 8) Click “OK”, the APP will jump to Fig.11 interface, the APP is binding the thermometer now. 9) After successfully binding the thermometer, the APP will jump to the Fig.12. Click the “return” on Fig.
Fig.10 Fig.
Fig.12 Fig.13 10.3 Measurement and data transmission 1) Please make sure that you have logged in to your account and click the app icon to enter the Fig.13 interface. If you don't log in, please enter your account and password to login first. 2) Click the“Ο”next to“temperature”on Fig.13, it will jump to Fig.14 interface.
Fig.14 3) Fig.15 Click "Synchronize" on Fig.14 and wait for the device to connect. The connection status is as shown in Fig.15 4) Power on your thermometer and measure the temperature according to the Fig.15 prompts. When the temperature value is displayed on your thermometer after the measurement, the app will automatically search your thermometer, the APP will jump to Fig.16 if it successfully connect to the your thermometer(at the same time, the LCD will display the Bluetooth icon).
Fig.16 6) Fig.17 After the data is successfully transmitted to the APP, the APP will display the measurement results,see Fig.17. 7) Click the “return”on Fig.17, it will jump to Fig.18 interface. 8) If you need to re-measure and transfer the measurement results to the APP again, you can click the "Synchronize " on Fig. 18 and follow the above method to perform another measurement.
Fig.18 9) Fig.19 If you need to view historical data, click "History record>" on the Fig.18 to enter the history interface, as shown in Fig.19. 10) Click the record group you need to query in Fig.19, and the APP will display the measurement results, as shown in Fig. 20. 11) If you want to delete the history record, Click the “select” on Fig.19, it will jump to Fig.21.
Fig.20 Fig.21 12) Select the history record that you want to delete, then click the “Delete”on Fig.21, then the selected history record will disappear from the interface. If you delete all the history record, the APP interface will shown as Fig.22. 13) Click the “<”on upper left corner can return to the previous interface. Note: Deleting the historical data of the APP will not cause the historical data of the thermometer itself to be deleted.
Fig.22 Fig.23 10.4 FAQ helping of APP 1) How to find the FAQ on APP? Click the “mine”in Fig.13 interface,you will find the APP version as shown on Fig.23,click the common problem, you will see the FAQ as shown in Fig.24, slide down the smartphone and you will see the content of Fig.
Fig.24 Fig.25 2) How to unbind the thermometer from the APP? Click ” ” in the upper right corner of Fig.20, then it will jump to Fig.26, click the “delete device”, it will jump to Fig.27, click the “confirm” to unbind the thermometer, the APP will automatically jump to Fig.5, unbind successfully.
Fig.26 Fig.27 10.5 App updates If there is any update to the APP, we will send you an update notice via email. When you receive the update notice of APP, please follow the steps in Section 10.1 to download and install the APP again. 11. Cleaning/disinfection and Care After use, the device surface (include the forehead cap, surface of probe, probe tip and enclosure) should be thoroughly cleaned and should be disinfected. Cleaning and disinfecting the thermometer at room temperature(under 10.0℃(50.
11.1.1 Before performing this cleaning procedure, wash your hands with hand sanitizer first. 11.1.2 Remove all residual foreign matters from the transducer using clean soft cloth immediately after use. 11.1.3 Take a piece of clean soft cloth soaked with 70% isopropyl alcohol to swab on the surface of the device until no visible contaminants remain. 11.1.4 Use a piece of clean soft cloth soaked with sterile water to wipe off the cleaning reagent on the surface until no visible cleaning agent remain. 11.1.
From the date of purchase, the product will enjoy a one-year free warranty with the purchase invoice. If the circuit diagram, components, necessary materials and electrical circuit maintenance are required during warranty service, please contact the manufacturer. Free warranty service will not be provided for failures caused by the following users' personal reasons: A. Wearable and consumable parts: covers and batteries; B.
enter the factory calibration mode and the LCD display “ ”. 2. Set the black body to 35.00℃(95.00℉), measure for 3 times, the measurement result shall be within 35±0.2℃(95.00 ± 0.4℉), otherwise, the thermometer is inaccurate. 3. Set the black body to 37.00℃(98.60℉), measure for 3 times, the measurement result shall be within 37±0.2℃(98.60 ± 0.4℉), otherwise, the thermometer is inaccurate. 4. Set the black body to 39.00℃(102.00℉), measure for 3 times, the measurement result shall be within 39±0.2℃(102.
The LCD is blank No batteries installed Install the batteries Batteries used up? Replace new batteries Batteries in wrong polarity? Take out battery, adjust batteries to proper polarity The thermometer power off Power on the device again automatically LCD shows Lo or Hi Exceed measurement 1 Make sure the probe tip and the range forehead cap is clean and there is Body mode: no obstruction prior to taking a <32.0℃(89.6℉) display temperature Lo; >43.0℃(109.
Waiting time is not enough. Wait at last 30 minutes. The measurement method is not correct. According to the requirements of Use the wrong the user manual to measuring. measurement mode. The surface of the probe tip According to the requirements of Inaccurate measurement or forehead cap is dirty. the user manual to cleaning. In forehead measure Please respect the measuring mode, the measuring distance shall be within 1.0cm to distance is not correct . 3.0cm.
Dispose of at public collection point in the EU countries – 2002/96/EC WEEE Directive. If you have any queries, please refer to the local authorities responsible for waste disposal. NOTES: ● Handing of battery and wastes method, please act according to the native law to proceed to handle. To protect the environment, dispose of empty battery at your retail store or at appropriate collection sites according to national or local regulations.
FCC statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
If Essential Performance is lost or degraded due to electromagnetic disturbances, this may result in inaccurate measurement and lead to mislead patients , please read below important information before to avoid possible electromagnetic disturbances.
Phenomenon Electrostatic Professional or test method facility environment Radiated RF EM fields healthcare Home healthcare facility environment +/- 8 kV contact IEC 61000-4-2 discharge Proximity Basic EMC standard +/- 2 kV, +/- 4 kV, +/- 8 kV, +/- 15 kV air 10V/m 3V/m IEC 61000-4-3 80MHz-2.7GHz 80MHz-2.
1845 1990 CDMA modulation b) 1900; GSM 217Hz 1900; DECT; LTE 1970 Band 1,3, 4,25; UMTS Bluetooth, WLAN, 2450 2400- 802.11 2570 b/g/n, RFID 2450, LTE Pulse modulation b) 2 0.3 28 0.2 0.3 9 217Hz Band 7 5240 5500 5100- WLAN 5800 802.11 a/n Pulse modulation b) 217Hz 5785 NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3.
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts(W) according to the transmitter manufacturer. NOTE 1 At 80MHz and 800MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations.
21. Manufacturer and European Authorized Representative Information Shenzhen Yolanda Technology Co., Ltd. Address: Room 201,Jinfulai Building, No.49-1, Dabao,Road,Dalang Area,Xinan Street,Baoan, Shenzhen,China. Tel: +86-755-21635022, +86-755-21635033 Customer service hotline :+86-400-998-2913 (service time:9:00 to 21:00 of working day) Email: service@yolanda.hk Website: www.yolanda.hk MedPath GmbH Address: Mies-van-der-Rohe-Strasse 8,80807 Munich,Germany E-mail: info@medpath.