Intelligent body temperature rapid screening system Instructions Welcome to use the Company's products, the Company reserves the right to the final interpretation of the products and the contents of the specification;
Directory Statement of responsibility............................................................................................. 5 Privacy Alerts....................................................................................................................... 6 About this document......................................................................................................... 6 Precautions ......................................................................................................
2.2.4 Desktop installation.................................................................................... 18 2.2.5 On-board installation................................................................................ 20 2.3 Face recognition access installation.............................................................. 22 2.3.1 Face Recognition Access Interface......................................................... 22 2.3.2 Cable requirements.........................................................
.2.1 Body temperature management........................................................... 32 4.2.3 Attendance record......................................................................................
Statement of responsibility To the maximum extent permitted by law, the products described in this manual (including its hardware, software, etc.) are provided "as is" and may be defective, error or faulty, and the Company does not provide any form of express or implied warranty. No compensation shall be made for any special, incidental, incidental or indirect damages caused by the use of this manual or the use of the Company's products.
Privacy Alerts If you install our products, you may collect personal information about faces. In the course of using the product, you will need to comply with the privacy laws and regulations of your region or country to protect the legitimate rights and interests of others. If you provide clear, visible signs, inform the relevant rights holders of the existence of video surveillance areas, and provide appropriate contact information.
Precautions Please note the installation environment of the equipment: Do not use the equipment in high temperature, low temperature or high humidity environment, the specific temperature and humidity requirements refer to the equipment's parameter table. Avoid placing equipment in direct sunlight, poorly ventilated locations, such as heaters, heating, etc. (ignoring this may result in fire hazard).
when there is a problem, use the packaging materials to pack the equipment, send it to the dealer or return to the manufacturer to deal with. The Company shall not be liable for accidental damage in transit caused by non-original packaging materials. Chapter OneProduct Overview 1.1 Introduction to the product Intelligent body temperature rapid screening system is a face recognition multi-functional product.
1.2 Product features Wall-mounted industrial design, stable performance, elegant and generous, smooth lines. With a 10.1/8-inch display, the software interface and operating tips are displayed to display the face frame and detect the closest face in real time. 2 million wide-angle cameras.
1.3 Product parameters model HV-8S101-T Hardware CPU Core Micro RK3288 QuadCore 1.8GHz QuadCore GPUMail-T764 Memory 2G (default) to expand up to 4G Store Default 16G Display 10.1 inch touch display, resolution 800 x 1280 Appearance material Aluminium housing, tempered glass panel Performance Identify height 1.4m-1.9m Identify distances 0.5-6m Temperature detection distance 0.
General parameters Operating temperature -10℃-+50℃ Working humidity 10-90% relative humidity, no condensation Working power DC 12V5A Size of the device 290mm*168.9mm Weight of the equipment About 2.0kg 1.4 Appearance 1.4.
1.4.
1.5 Product size Chapter 2 Equipment Installation 2.1 Installation environment Install the device indoors to avoid direct sunlight/bright light。 Please keep the ambient light light illumination at 100 Lux When the operating temperature of the equipment is below 15 degrees C, warm up the device with power up for 15 minutes to avoid abnormal temperature measurement sensor. Light and environmental instructions: 1.
2. Avoid backlight, direct sunlight, sunlight through windows, light at close range 2.2 Device installation 2.2.1 Pre-installation Before the terminal installation, prepare the relevant installation tools such as impact drill, wrench, tape measure, screwdriver, etc., check whether the surrounding environment is suitable for installation, and then understand the installation method, check whether the terminal functions are intact, parts are complete. 2.2.
situation. Connection of the cable Remove the rear cover of 4 fixed screws, according to the image below to connect the adapter and antenna (if required), the terminal can be used offline, such as offline use, the terminal does not need to access 4G/ network cable, after the connection is completed to install the cable on the back cover (before installing, please disconnect the adapter power operation).
Ground id In order to improve screening efficiency, the test area identification can be pasted on the ground in front of the terminal to direct the screening object to stand in the designated area for testing.
2.2.3 Stick-type mounting 1. First with bolts the plastic counterweight block, stainless steel site and pole fixed. Install the following diagram 2. Fixed terminal backplate holder 3. Install the installed terminal to the pole, 4. Connecting device cables 5.
6.Adjust the terminal angle, display the portrait information in the middle of the screen as shown in the figure below, and lock the screws. 2.2.4 Desktop installation 1.Select the installation location (recommended installation height of 1.4M) 2. Secure the desktop mounting bracket.
3. Install ingress support 4. Connecting device cables 5. Labeling In order to improve screening efficiency, the test area identification can be affixed on the ground in front of the terminal to guide the screening subject to stand in the designated area for testing, as shown in the figure below 6.
2.2.5 On-board installation 1;Select the safety lever to be installed (near the front door or driver's guard door) and measure the mounting height and mark it. Paste the anti-slip adhesive into the car installation box hugging hoop, install the car installation box. As shown in the figure below; 2.
3. Terminal fixation The temperature monitoring terminal connects the power cord and related cables, and then the temperature-measuring terminal is embedded in the vehicle installation box, and then the screws are secured. Here's the picture 4.
5. Adjust the terminal angle, display the portrait information in the middle of the screen as shown in the figure below, and lock the screws 2.3 Face recognition access installation 2.3.1 Face Recognition Access Interface Face Recognition Access System Interface::K1 K1,K2 K2,IO, 3.
2.3.2 Cable requirements Instructions for the use of the cable: If the 1.0mm national standard line is used, a 12V switching power supply is required and the on-site construction wiring distance (switching power supply to equipment distance) does not exceed 20m. If the 1.5mm national standard line is used, a 12V switching power supply is required and the on-site construction wiring distance (switching power supply to equipment distance) does not exceed 30m. If the national standard line of 2.
2.3.4Connecting the cable The appliance must use the recommended wire assembly (power cord) in the area and use it within its rated specifications. Please carefully complete the connection of the circuit. Violations of the relevant connection procedures will result in damage to the device. All external wiring parts must prevent short circuits. The power cord cannot be connected until all the wiring connections have been completed.
Chapter III Temperature Measurement Guidelines 3.1 Equipment calibration After the terminal starts, the system will automatically calibrate the functions, please wait patiently for 10 to 15 minutes, please do not turn off the power in the middle. 3.2 Temperature test When the screening object enters the detection area, the face is right towards the display. Move back and forth in the detection area to make the face fully displayed in the detection area in the display.
When the terminal is tested for temperature, a tone is sent "Please keep" and after keeping the face in the detection area for 2 seconds, the terminal emits a tone "Body temperature is normal, the test is over" and the temperature data is displayed. If the body temperature is at the terminal at 37.
displayed. When testing with a mask, individuals may be unable to detect faces because facial features are obscured by masks, making it impossible to conduct a temperature test. In this case please adjust the mask properly downwards and retest. All test results are automatically saved to the TF card in the terminal (2000 people are screened daily, test data is stored for approximately 200 days and will be overwritten after more than 200 days). Chapter 4 Cloud Services 4.1 System management 4.1.
The following dialog box pops up Edit account number, user name, mobile phone number, gender information, select the group, set the role (user level super save can be. User queries [System management]-----[ User management]-----[ Search] Enter the account number or keyword you want to query in the search dialog box, and click to search for relevant information. 4.1.
Modify Device name: Customers can set their own device name SIM card number: record the use of SIM card number, easy to manage and statistics Installation address: Address used by the device Equipment types: attendance equipment, access control equipment, canteen equipment, data processing terminals, rapid screening systems, multi-functional temperature monitoring machine Grouping: Select to set up grouping (group settings see Group Management) Device not updated: Set whether the device is updated
4.1.4 Group management The device is divided into different institutions, so that users can divide permissions. [System management]-----[ Group management]-----[ Increase] Grouping can be added two levels, different users see the content related to grouping, parent grouping users can view the content of child groups, version management is also related to grouping The addition dialog box looks like this: Group Name: User Edits Description: Describe the place or place where the equipment is used.
4.1.6 Employee management Conduct employees and manage department groups. Increase your staff [System management]-----[ Employee management]-----[ Increase] Enter information such as employee name, gender, work number, ID number, employee status, selection grouping, department, upload profile picture, etc. Modifying employee information The editing information is shown in the image above.
Description: When an administrator is working on an employee, the employee's information is synchronized to the front-end device in real time The size of the picture is limited to 100K, the picture must contain clear face information 4.2 Feature management 4.2.
[Feature management]-----[ Attendance record]-----[ Search] Select the appropriate search criteria and click search for a query.
FCC WARNING This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.