User Guide

TRL1safety
interlocking
deviceseries
Functionalfeatures
TRL1safety interlockingdeviceseriesisbased on RFID radio
frequency induction coding technology, using monitored stainless
steel latch mechanism, used for personnel or machine safety
protectivedoordevice.Thesecuredual-channeloutputtechnology
can achieve safety level SIL3 or PLe, which can be used with the
safetylatch.
Technicalparameter
※Themaximumpoweris10W(noload)andthedurationis200ms

Safetylevel
2-wayredundantPNPorNPNoutput(withself-
diagnostictestpulses)
Safetyoutput
Latchinsertiondeviation
LockingretainerFmax(ISO14119)
LockingretainerFzh(ISO14119)
Minimumradiusoftherevolvingdoor
Workingvoltage
Ratedpower
Outputcurrent
Outputconductionvoltagedrop
Leakagecurrent
Operatingfrequency
Responsetime
Risktime
Starttime
Protectiongrade
Operatingtemperature
Relativehumidity
Material
IS013849-1IEC/EN60947-5-3
Cat. 4 /SIL3 dual channel interlock conforming
toIS013849-1issuitableforPLe/PLd.
Standard
Safety
Classification
Output
Protect
Overheatprotectionstopsandrestarts
Reversepolarityprotection
Transientnoiseprotection
Failurepulseprotection
Technicalparameters
Safetyshortcircuitprotection
Currentlimit
Overloadprotection
Overvoltageprotection
CE/CQC/FCC
Certification
1PNPorNPNoutput(dooropeningandclosing/lock
locking/auxiliaryoutput/faultindicator).
PFHd
MTTFd
Max.±2mm
9750Nor3000N
7500Nor2000N
220mm
DC24V±15%
4.6W(Noload)
Max.200mA
2.5V@200mA
100uA
0.5Hz
100ms(Workingindependently)
100ms
3.5s
Ip67
0...+55℃
5...95%
Nylon/zincalloy/stainlesssteel
288
<4.2x10
-8
Auxoutput
SHENZHENTONGCHUANGMECHANTRONICSCO.,LTD.