Rev: A1 Body Composition Analyzer and Scale SF1402B Instruction Manual z Thanks for purchasing the Body Composition Analyzer and Scale manufactured by Bpump. z Please read the instruction manual before usage; z Please dispose the Body Composition Analyzer and Scale and battery in accordance with local regulations.
Rev: A1 Table of Content 1. Safety Information ...................................................................................................................... 3 1.1. Danger ............................................................................................................................... 3 1.2. Warning............................................................................................................................. 3 1.3. Precaution .............................................
Rev: A1 1. Safety Information 1.1. Danger (Operation errors lead to death or serious injury) Do not use in conjunction with following electronic medical device in avoid of life threating. ● Implantable medical device such as pacemakers; ● Life-sustaining medical device such as artificial heart; ● Pregnant women are not suggested to use the device for physiological index measurements such as body fat ratio. 1.2.
Rev: A1 z z z z z z z z falling. Please do not reverse the battery poles during battery replacement in avoid of harm caused by battery leakage, fever or broken. Please take out the battery in case of non-use for a long time (3 months above). Please stand up straight and keep still during the measurement in avoid of affecting measurement result. Please do not place the device where has water, direct sunlight, direct air condition wind, please do not place next to the fireworks.
Rev: A1 3.
Rev: A1 4. Operation Instruction 4.1.
Rev: A1 2) 3) ifmeasurements are taken once a day at room temperature (23°C); The batteries enclosed are used for trial, which may be used up soon; Do not use rechargeable batteries, otherwise may cause misoperation. Battery symbol flashing means that the battery is running out, replace four new AAA alkaline new batteries of same model if happens; Please replace the battery at power off status; The personal data seted in advance will be kept however battery replaced; 4.3.
Rev: A1 confirmation (fig6); Fig 3 Fig 4 Fig 5 Fig 6 Setting is complete till now, you can start physiological indexesmeasurement such as weight, the body fat ratio, visceral fat index and others. 4.4. Take Measurement 4.4.1. Precautions for Measurement z z Personal data setting is needed if you want to use under “Group” function to track your measurement results; “Guest” function is an option if you do not need to store the personal data.
Rev: A1 Note: on the screen indicates the device has finished measurement (fig 12); barefoot step on the electrode slice double foot at the same time Fig 10 Fig 11 Fig 12 4.4.2.2. Weight Measurement Only 1) Power On/Off Power on the device and wait for a while, "0.
Rev: A1 10kg on the device. 2) Weight Measurement (1) Step onto the platform with correct posture barefoot, otherwise the device is unable to display correct physiological indexes (fig 10, fig 11); (2) Stand still and keep your posture for a while, the weight value will display on the screen (fig 13); (3) Step off the platform after the measurement done; Fig 13 4.4.3. Display the Measurement Result 4.4.3.1.
Rev: A1 4.4.3.2. Unit Switch Under standby status (showing "0.0 kg" on the screen), you can enter “unit switch” interface by long pressing "SET" button; use buttons to select the unit, then press SET button for confirmation; The available units are metric and imperial such as "cm , kg","ft, lb "(fig15, fig 16). Fig 15 Fig 16 4.4.4.
Rev: A1 5. Reference Standards 5.1. Weight Standard Weight Result ≤-10.0% -9.9%~9.9% 10.0%~19.9% Low Normal Mild High ≥20.0% 5.2. Body Fat Ratio Standard Body Fat Ratio is the proportion of fat to the total body weight. Body Fat Ratio Male Female 2.0~13.9% 10.0~20.9% 14.0~17.9% 21.0~24.9% 18.0~24.9% 25.0~31.9% ≥25.0% ≥32.0% Result Low Normal Mild High 5.3. Water Content Standard Total Body Water is the total amount of fluid in the body expressed as a percentage of total weight.
Rev: A1 BMI 18.8~22.9 24~27 ≤28 Result Normal Mild High 5.6. Muscle Mass Muscle Mass (including skeletal and smooth muscle) make up 70% of weight in ordinary population. 5.7. The Average Bone Mass Presumption ≤60k bone mass 3.2kg presumption Weight Male 60kg~75kg 3.95kg ≥75kg 4.4kg ≤45kg 2.2kg Female 45kg~60kg 2.8kg ≥60kg 2.9kg 5.8. Basal Metabolism Age 18~29 30~49 50~69 70≤ Male ideal body Basal weight(kcal metabolism ) standard values (kcal/kg/da y) 64.7 24 67 22.3 62.5 21.5 56.7 21.
Rev: A1 6. Error Indication Error Err H Cause 1) The user sways or leaves the device during measurement; 2) Do not take measurement barefoot; Correction Do not sway or leave during measurement; Take measurement barefoot; 3) The device is unable to detect the human impedance. Step onto the platform with correct posture barefoot to take measurement.
Rev: A1 7. Trouble Shooting PROBLEM Device shows "0.0 kg", or almost no value. increase after stepping on; Abnormally high or low measurement value; Abnormally high or low measurement value; The measurement value differs widely for each measurements; CAUSE Step onto the device before "0.0" displayed; Step onto the device after "0.0" displayed; Wrong Posture; Please follow the correct posture measurement.
Rev: A1 8. Product Specification Product Name Body Composition Analyzer and Scale Model SF1402B Power Supply 4 AAA battery ≤50kg: ±0.4kg 50kg~100kg: ±0.5kg ≥100kg: ±0.6kg Auto power off Unattended 1min Memory 4 groups parameters which have been seted up Accuracy Setting Item Age: 7~99 years old Sex: Male/Female Height:100~220cm Display Range Display accuracy Weight: 0.1kg Body Fat Rate: 0.1% Water Content: 0.1% Muscle Mass: 0.1kg Bone Content: 0.1kg Basal Metabolism: 1Kcal BMI: 0.
Rev: A1 Disposal This product must not be disposed together with the domestic waste. All users are obliged to hand in all electrical or electronic devices, regard less of whether or not they contain toxic substances, at a municipal or commercial collection point so that they can be disposed of in an environ mentally accept able manner. Please remove the battery before disposing of the equipment.
Rev: A1 9. CARE AND MAINTENANCE 9.1. Daily Maintenance z z z z z The device should be cleaned before storage; Soft dry cloth can be used to remove dirt on the device; Do not wash the device, otherwise it may malfunction; Do not use volatile and harsh detergent to remove dirt, or device will be faded or malfunctioned; In case that device needing clean, wipe the device with wrung soft cloth which had been soaked in water or neutral detergent, then wipe the device with another dry soft cloth; 9.2.
Rev: A1 ◆ Electromagnetic Compatibility Guide Important information regarding Electro Magnetic Compatibility (EMC) With the increased number of electronic devices such as PC’s and mobile (cellular) telephones, medical devices in use may be susceptible to electromagnetic interference from other devices. Electromagnetic interference may result in incorrect operation of the medical device and create a potentially unsafe situation.
Rev: A1 Guidance and manufacturer’s declaration – electromagnetic immunity The [EQUIPMENT or SYSTEM] is intended for use in the electromagnetic environment specified below. The customer or the user of the [EQUIPMENT or SYSTEM] should assure that it is used in such an environment.
Rev: A1 Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEMS that are not LIFE – SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity The [EQUIPMENT or SYSTEM] is intended for use in the electromagnetic environment specified below. The customer or the user of the [EQUIPMENT or SYSTEM] should assure that it is used in such an environment.
Rev: A1 Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM – For EQUIPMENT and SYSTEMS that are not LIFE – SUPPORTING Recommended separation distances between portable and mobile RF communications equipment and the [EQUIPMENT or SYSTEM] The [EQUIPMENT or SYSTEM] is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Rev: A1 ◆ Product Registration Information Production license No.: Guangdong FDA Device Production: 20081657 Registration certificate No/product specification No: Guangdong Device Registration: xxxxxxxx ◆After-Sale Service Manufacturing Enterprises: Shenzhen Pump Medical System Co., Ltd.