Parts List/Tune Up Info

2AZBU-SM651RX_Tune Up Procedure
Measurement Procedure:
1. Set the device to operational voltage and on a predefined channel in a special test mode.
2. The actual output power is measured at several power levels.
3. The gain factors of each individual device are adjusted until the target value is met. The
appropriate gain control settings for each output power level are stored in each device
individually (for each power level). The user has no possibility to change these settings
later on.
4. The maximum gains of each individual device are adjusted and measured until the target
value is met. The production target power with tolerance compiles with the maximum
power in test report.
Average Power Output:
Mode
2.4G custom
Channel
Low
Mid
High
GFSK(1Mbps)
10±1dBm
10±1dBm
11±1dBm
Then these appropriate rated RF output power settings are stored in each device
individually. The user has no possibility to change these settings later on, and during
manufacturing each device will be individual calibrated. The measurement is done in
fully calibrated setup, which is based on the base station simulator. Furthermore, the
highest power level is verified afterwards in a call measurement on three
channels(low, middle and high).