CONTENT 1.SAFETY INSTRUCTIONS 2.PRODUCT OVERVIEW 2.1 Package list 2.2 Parent unit(monitor) 2.3Baby unit(camera) 2.4 Icon overview 3. USING THE BABY MONITOR 4. FUNCTION OVERVIEW 4.1 Vox setting 1-2 3 3 4-5 6 6 7-8 9 9 4.2 Feeding timer setting 10 4.3 Lullaby setting 11 4.4 Pairing the camera and monitor 12 4.5 Delete the camera 13 4.6 Temperature settings 14 4.6.1 Temperature alarm setting 14 4.6.2 Temperature Hi/Lo alert limits 15 5. TECHNICAL DATA 16 5.1 System general 16 6.
4 6 7 1 5 8 9 2 3 1 Power key: Long press to turn on / o 2 the monitor ; short press to screen on / o Menu/Exit: Press short Menu / Eixt key the menu will pop up, and press again to EXit. 3 MIC: 4 Power&Charging Indicator LED: When talking to the baby, collect the voices of the parents. *The LED shows red when charging when the display is o . *The LED displays shows green and red when charging under the power-on state. *The LED displays shows green after the battery is fully charged.
8 Volume + / Up key: Press the UP key to increase the volume. 9 OK: Press OK key to view / scan camera or to con rm. Talk to baby: *To talk , press and hold the talk key on the front of the monito; release to turn it o . *Bear in mind that you can't listen to your baby whilst you're talking to them ; to listen to it , you will have to stop pressing this button. Brightness + / Right key: Press the Right key to increase the brightness.
1 2 3 4 5 8 7 6 9 1 Light sensor 6 Speaker 2 infrared LEDs 7 Pair key 3 CMOS sensor 8 DC-Jack 4 Power LED 9 Temperature sensor 5 MIC Antenna VOX 80
Step1: Charge the mornitor by connecting the A/C adapter included in this package to the monitor and a socket . It takes about 4 hours for the monitor to be fully charged. Charging: Red/green Fully charged: Green Step2: Use the provided AC adapter included in this package to connect the wall outlet with the baby unit.
Step3: Place the camera at least 3ft / 1m away from your baby. Gently press and hold the Power Button for 3s to turn on the monitor, then you can see the live view. Step4: Follow your needs to adjust the sound, brightness, and reasonable placement of the camera.
4.FUNCTION OVERVIEW 4.1 VOX SETTING This mode allows you to control the sound activation of your baby monitor. The VOX default setting is OFF. If there is no sound around the camera within 30 Seconds, it will stop transmitting. The monitor screen turns o when the camera is not transmitting.
4.2 FEEDING TIMER SETTING You can use the alarm to remind yourself to feed baby/change diapers/ sleep,etc Step1: Press Menu / Exit key and the menu will pop up. MENU VOX Step2: Select the alarm icon and press OK key to enter into sub-menu. Step3: Press the NAVIGATION key to select desired alert time. Step4: Press OK key to con rm. Step5: Press the Menu / Exit key to Exit.
4.3 LULLABY SETTING You can soothe the baby to sleep by playing a gentle lullaby from the baby unit. Step1: Press Menu / Exit key and the menu will pop up. MENU VOX Step2: Select the lullaby icon and press OK key to enter into sub-menu. Lullaby 1 2 3 4 5 Step3: Press the NAVIGATION key to select desired alert time. Step4: Press OK key to con rm. Step5: Press the Menu / Exit key to Exit.
4.4 PAIRING THE CAMERA AND MONITOR Step1: Press Menu / Exit key and the menu will pop up. MENU VOX Step2: Select the camera icon press the LEFT key and press OK key or RIGHT key to enter into sub-menu, to select the camera to be paired. Camera Step3: Press OK key to start the pairing . While the screen shows pairing then press the PAIR button 7 on the back of camera. Pairing Step4: Once paired , then the screen will display the image from the camera.
MENU VOX Camera Pairing Unpair YES NO
4.6 TEMPERATURE SETTINGS 4.6.1 Temperature Alarm Setting Step1: Press Menu / Exit key and the menu will pop up. MENU VOX Step2: Select the temperature icon and press OK key to enter into sub-menu. 18 38 Min Max Step3: Press the LEFT key or RIGHT key to select between ℃ or ℉, Follow up your needs to set the maximum and minimum alarm temperatures. Step4: Press OK key to con rm. Step5: Press the Menu / Exit key to Exit.
4.6 TEMPERATURE SETTINGS 4.6.2 Temperature Hi/Lo Alert Limits Step1: Press LEFT key or RIGHT key to select Max (red) or Min (green) for Hi/Lo limits settings. 18 38 Min Max Step2: Press the up key/down key to adjust the Hi limit when Max (red) is selected. Step3: Press the up key/down key to adjust the Lo limit when Min (green) is selected. Note: Press OK The high temperature alarm default setting is 31°C, and the low temperature alarm default is 14°C.
Q1. Why the camera can't be paired with the monitor? *the camera is properly connected to the power supply, try to replace the charging cable and charger and try again. *Make sure the camera and the monitor are within the e ective transmission distance. *Press the reset key at the back of Parent unit and try to pair them again Q2. Why are the camera and display always disconnecting? *The camera or monitor may be placed too close to many metal objects.
Q5.What should I do if the picture on the display frozen? Restart the baby unit (plug out the adapter then plug it into the socket again). Press the reset key at the back of parent unit (hide behind the stand). Q6.Why the temperature is inaccurate? *The temperature sensor is positioned very close to the baby unit and when it warms up during operation.
CUSTOMER SUPPORT If you encounter any problems in the process of using the product, please feel free to contact us,we will reply to you within 24 hours and resolve the issue in a way that satis es you. Customer service e-mail address: support@anmeate.
FCC Warning Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.