External powered DC12V
Static current consumption: 18mA
Alarm current consumption: 30mA
When powered,the green LED light for 3
seconds and flicker 2 seconds and off
the red LED flicker about isseconds,after
3 minutes,the detector comes into work
states.
Alarm mode:Red LED light about 3S
Relay output:NC
Wireless transmitting distance:150m
Transmitting frequency:433MH
The max recharge caurrent: 120mA
Detection range:12m(25 )
3.Installation
2 Specification
3.1 Guide
Do not face to cold or
heat source
Do not fact to sun light Keep away from high-
voltage wire
1.Introduction
Installation base
should be stable
Do not face to metal wall
FT-89R is the best indoor/outdoor motion detector with passive infrared and microwave.It's water proof and all weather resistant with two layer
stable housings.FT-89R combines a variety of detection techniques which enable it to work in the most difficult environment where needs high security
while maintaining immunity to false alarm.The infrared sensor adopts nice lens produce three-dimensinal thermal imaging of the protected area .
Combinging the four-element microwave scanning contributes to an amazing detection capacity.Using this technique allows high sensitivity but
lowest false alarm.FT-89R is equipped with unique protection mechanisms against any attempt to damage or to disable its operation.
3.2 Disassemble guide
2.Pull out the bottom of the cover
3.Remove the PCB
1.Loose screw
Internal battery-powered
Low battery ararm:2t will send Low battery
report when the detectoy low battery
and send battery resume report when the
battery resume
Relay outpnt:N/O(when external power
disconnect,the Rely output will convert
to N/O from N/C afert powered by battery
about 2 minutes,external power resume by
contrary.)
Static current consumption: 18mA
Alarm current consumption: 80uA
4.Remove the middle case
Enstarlation
Suggest installation height:2-3
meters from ground
45 corner
fixing
Surface
fixing
A.Mark the drilling
points and make
holes.
B.Draw the cable
from back channel
C.Fix the base
cover on the wall
with two screws.
D.Put the PCB back on
the cover with clips and
fasten screws.
Suggest corner installation
3.3. Stand-by battery replacing and using
When battery is lower power, it will send related signal
to control panel,so user should replace battery with
same spec.(as right fig.)
On BUS working mode,if this model of detector more than
4pcs in the system,you need put battery inside to assure
the system will not overload.
1
2
3
Open battery box
Install new
battery
Put on the cover
and fix with
svrews