ST-IIIB user manual P/N 20130320-1
U ser 册 手 品manual 产 Brief Dear customer: Congratulations on purchasing you new security systeman thank you for the confidence you have shown in us.You have chosena high -quality. Product that has been produced,tested and packed wthegreatest care.Please familiarize yourself with these instructions before atte mpting operation will only been sure if it is fitted properly.We hope your new security system will bring you lasting pleasure.
U ser 册 手 品manual 产 Content Chapter I Introduction 1 Chapter 2 Installation and Connection 4 2.1 Installation 4 2.2 Connection(N.O. N.C) 4 2.3 Install wired detector 2.4 Intall wereless detector 4 5 Chapter 3 Keybad and Operation 5 3.1 About panel 5 3.2 Basic operation 7 3.3 Flashes when phone line cut 7 3.4 Host arm and disarm 3.5 Alarm procedure Chapter IV Voice alarm receiving and GSM control 4.1 Remote phone control 8 10 11 11 4.2 Alarm receiving phone operation 11 4.
U ser 册 手 品manual 产 6.4.2 Set entry delay 18 6.4.3 Set exit delay 6.4.4 Set siren time 6.4.5 Set ring times 18 18 18 6.4.6 Set detector loss inspection 6.4.7 Set arm/disarm tone 6.4.8 Set arm/disarm report 6.4.9 Set others 6.4.9.1Set emergency alarm siren type 19 19 20 20 20 6.4.9.2 Ac off inspection time setting 6.4.9.3 Magnetic contact inspection 21 21 6.4.9.4 Check wireless detector tamper 6.4.9.5 Set force arm 6.4.9.6 Set telehpone line disconnect remind 6.4.9.7 Set zone alrm times 6.4.9.
U ser 册 手 品manual 产 6.6.1 Set zone attribution 6.6.2 Set zone siren type 6.6.3 Set wired zone loop type 6.6.4 Set wired zone response speed 6.6.5 Set related zone 6.7 System maintance 28 28 28 29 29 30 6.7.1 Set timing operation 31 6.7.2 Recording 31 6.7.3 Play recording 31 6.7.4 Set programmable output port 31 6.7.5 Delete system events 32 6.7.6 Restore to factory default 32 6.8 Set GSM module 6.9 Advanced setting options 32 34 6.9.1 GPRS enable and disable 6.9.2 Set sever IP address 6.9.
User 册 手 品manual 产 Chapter I Introduction 1.1 Function Introduction I 、Alarm mode: with PSTN and GSM network alarm, GSM network with GPRS function(GPRS function is for China market only), remote arm and disarm panel through CMS or SMS CID protocol, SMS notification, the priority of PSTN and GSM network is Optional. 2、With a new large-screen, full-touch buttons, LCD graphic display steps, work status,Alarm process easy and intuitive.
U ser 册 手 品manual 产 13、Wireless zones, each wireless zone can automatically learn the codes or be coded manually via the keyboard. 14、8 wired zones, User can set the circuit type and speed of response, support N.O, N.C. 15、Enable enroll total 8 wireless remote,8 electronic switch,1 pc of wireless doorbell and Unlimited for quantity of one way wireless siren. 16、 Follow me phone #,two for CMS,four for private alarm receiving. 17、Status inspection function:Enable record and inquiry 120 alarm event messages.
U ser 册 手 品manual 产 26、The tampering alarm: cut the cable between wired detectors and the panel will trigger larm, the telephone line cut will autom atically trigger siren alarm. When someone deliberately dismantled the panel, it will alarm when triggering tamper switch at the back of the panel. 27、Timing arm/disarm:Enable set 4 group time arm/disarm time. 28、CMS communications test: The panel will send a message to CMS at the pre-set time interval to inspect the communicaiton if normal.
U ser 册 手 品manual 产 Chapter 2 Installation and Connection 2.1 Installation 1. Fix the bracket to the wall and hang the pane to the bracket 2. The large metal objects can not be placed around the panel, so as not to affect the wireless signal. 3. Make sure to place the panel within the wireless range of all wireless accessoris and pay attention to the hidden 2.2 Connection(N.O. N.C) As pictures N.C N.
User 册 手 品manual 产 To arm the panel. The zone number will be also display on the LCD screen. At this time arm system is not allowed unless you force arm. 2.3.2 The control pane can power 15V, 100mA to detectors. The max curent is 100mA. Do not exceed 100mA, otherwise please use extra power supply. 2.4 Intall wereless detector 2.4.1 As the detector`s manual says,install coded detector in the area 150m from the control panel.Please test and make sure detector can work with control panel normally. 2.4.
U ser 册 手 品manual 产 Arm led: Light on under armed status, Light flashes under stay status. Disarm led: Light on under disarmed status Trouble led: Light on when with zone trouble. Light flashes when AC cut. Alarm led: Light flashes when alarm.
User 册 手 品manual 产 3.2 Basic operation Factory default Adminitrator password: 012345 16 User passwords, NO. 01 factory default is 1234. No. 02-16 of the user password is blank and can not enter the user setting untill user set the password.
U ser 册 手 品manual 产 Flashes when phone line cut. Light on when phone line is normal. Flashes when GSM not ready, Light on when GSM is normal. Flashes when GPRS disconnected with CMS. Light on when GPRS is connected well with CMS. Flashes under sleep mode. Light on uder normal working mode.
U ser 册 手 品manual 产 ☆ Home Arm ☆ Panic ~DI~ DI ~ M D ~DI~ DI ~ Y Press the key for home arm on the remote or "HOME"key on the keypad, then you will hear "s ystem stay " And it display home arm icon on the LCD screen. M D Y Press the panic button on remoter,or press" 3 " key on panel for 3 seconds.
U ser 册 手 品manual 产 3.5 Alarm procedure Tele Telephone 1st 2nd telephone Cell phone 3rd 4th 3.The panel will dial 1-4 telephone numbers as preset.If more than 4 numbers,the panel will W ire d start with second telephone number, then 3,4... Alarm software Alarm situation found, start to send message 1.The detector activated send alarm infor mation to alarming center. CMS 110 alarm center 2.The panel use Ademco Contact ID to send W ire le ss alarm information to alarming center.
U ser 册 手 品manual 产 Chapter IV Voice alarm receiving and GSM control 4.1 Remote phone control User can remote control the system by phone call, after the preset ringing times then panel will off hook the phone then enter the 4 digit user codes according to voice prompting and operate as per the voice prompting. 1 Telephone line The phone rings is 7 times, after 7 times ring, the panel will off-hook automatically.
U ser 册 手 品manual 产 4.3 GSM remote operation ( talk-back function added) When alarm occurs, GSM will call the preset voice number, when pick up the call,enter 4 digit user code, then voice prompt: Press 1 to arm system, Press 2 to disarm system, Press 3 to Stay arm, Press 4 to check system status, Press 5 to appliance switch control, Press 9 to talk-back, Press 0 to Disconnect. 4.
U ser 册 手 品manual 产 Chapter IV Voice alarm receiving and GSM control Press[*] for 3 seconds + * 1 2 3 4 + 1 2 3 # Set system clock Set user password Set voice phone 5.1 Set system clock For example: set system clock as : 22:59:36 22/12/2012 Press[*] for 3 seconds Enter passord + 1 * Please enter system clock, pressconfirm + key tosave,press back key toexit. + 5 9 + 3 Min 1 4 + # + 1 2 3 2 + 1 Y 2 + 2 + 2 M # D 2 2 H 6 + # Sec on screen According to flash of Y.M.D.H.Min.
U ser 册 手 品manual 产 Chapter VI System Setting Press[*] for 3 seconds * + 0 1 2 3 4 5 + # 6.1 Set password 1 2 3 4 5 6 7 8 Set GSM 9 Set advanced options Set password Set CMS number Set voice phone Set system options Set wireless devices Set zone System maintenance Press[*] for 3 seconds * + 0 1 2 3 4 5 + # + 1 # Then operate according to the voice prompt as below. Set password [1]Set Admin password 1 # Enter password, press confirm key to save, press back key to exit.
U ser 册 手 品manual 产 2.Administrator password is 6 digit, user password is 4 digit, can set 16 user passwords, corresponding password No. from 01 to 16, but No.2-16 password can’t enter user setting. 3.If forgot the password, when the alarm is powered on, for the first minute,the administrator password is 000000.
U ser 册 手 品manual 产 Note: 1.The user code is the identification code in CMS setting, CMS 1 and CMS 2 use the same user code; dialing times can be set 1-15 , communication inspection interval time can be set 0-999 hours, the common setting is 24 hours. 2.When set phone number, long press 1, display the letter P, means pause 1 second when dialing, when the telephone line which connect to the alarm panel is sub-line, need a pause dialing. 3.
U ser 册 手 品manual 产 Note:1.dialing times can set 1-15 2.When panel call user’s phone, if you enable password check, it will prompt enter user password when pick up the call. For example: Set voice phone No.3 is 12345678 Press[*] for 3 seconds 0 1 2 3 4 5 Enter password + * Please enter phone number, press * key to delete, Long + press 1, dialing pause 1 se cond, press confirm key to save, press back key to exit. + + # + 3 # 1 2 3 4 5 6 7 8 3 # + # 6.
U ser 册 手 品manual 产 6.4.2 Set entry delay When trigger alarm, the panel will give delay alarm time(default setting is 10s) For example: Set entry delay to 20seconds Press[*] for 3 seconds * Enter password + Please enter entry delay time, press confirm key to save, press back key to exit 0 1 2 3 4 5 + 0 2 0 + + # + 4 # + 2 # # Enter 3 digit number from 0-255, add 0 if less than 3 digit. Note: Entry delay is just effective for delay zone. Other zone types can’t enter delay. 6.4.
U ser 册 手 品manual 产 Press[*] for 3 seconds * Enter password + 0 1 2 3 4 5 Enter password.... Please enter ring times, if set as 0, the phone will not off hook, press confirm key to save, press back key to exit + + 0 5 # + + # 4 # + 5 # Enter 2 digit number from 0-15, add 0 if lower than 10. Note: The max. Ring times as per the local communication, if set 0, not off-hook. 6.4.
U ser 册 手 品manual 产 6.4.8 Set arm/disarm report Set if arm/disarm report to CMS or not( the default setting is disabled) For example: Set arm/disarm report to CMS Press[*] for 3 seconds Enter password + * 0 1 2 3 4 5 Please choose arm/disarm report: 1. enable, 2. disable, + press confirm key to save, press back key to exit 1 + + # + 4 # + 8 # # 6.4.
U ser 册 手 品manual 产 6.4.9.2 Ac off inspection time setting. When the AC power is off, delay to report to CMS(factory default delay time is 30 min) Example:set AC off inspection time as 15 min Press[*] for 3 seconds Enter password + * + 0 1 2 3 4 5 + Plsease enter 0 to 255 minutes AC off duration time.press + confirm key to save, press back key to exit. 2 # + # 4 # 0 1 5 + + 9 # # 6.4.9.
User 册 手 品manual 产 Press[*] for 3 seconds Enter password + * + 5 # 0 1 2 3 4 5 + + # Please choose: 1. Auto force arm 2. Forbid force arm via remote control. Press confirm key to save, pressback key to exit. + 1 4 # + + 9 # # 6.4.9.6 Set telehpone line disconnect remind(factory default delayed siren sound remind) Example : disable telephone line disconnet remind Press[*] for 3 seconds Enter password + * + 6 # 0 1 2 3 4 5 Please choose telephone line disconnect remind: 1.
U ser 册 手 品manual 产 6.4.9.9 Set AC off remind(factory default remind by SMS) Example:disable AC off remind Press[*] for 3 seconds Enter password + * + 9 # + # + 4 # Please choose AC off remind: 1. SMS remind 2. Voice phone remind 3. Disable + Press confirm key to save, Pressback key to exit. 3 + # 0 1 2 3 4 5 + 9 # 6.
U ser 册 手 品manual 产 6.5.1.2enter remote control code Example: manaul enter the address code of remote 112113114 to the #8 remote in alarm pa Press[*] for 3 seconds Enter password + * + 2 # 0 1 2 3 4 5 Please enter the serial number of remote control. + Press confirm key to save, Pressback key to exit. Please enter remote control Number + Press confirm key to save, Pressback key to exit. + # + 8 + # + 5 # + 1 1 2 1 1 3 1 1 4 1 # # 6.5.1.
User 册 手 品manual 产 6.5.2.2 enter detector code Example: manual enter the address code of detector 011022033 to the # 7 detector in alarm panel Press[*] for 3 seconds Enter password + * + + 2 # 0 1 2 3 4 5 Please enter detector Number. + Press confirm key to save, Pressback key to exit. Please enter detector code Press confirm key to save, Pressback key to exit. + 0 7 + + # + 5 # + 2 # # 0 1 1 0 2 2 0 3 3 + # 6.5.2.
User 册 手 品manual 产 6.5.3.2 Delete appliance switch Example: delete the # 4 appliance switch Press[*] for 3 seconds Enter password + * + 0 1 2 3 4 5 + # + Please enter the serial number of appliance switch to delete, enter 0 to delete all + Press confirm key to save, Pressback key to exit. 2 # 5 # + + # 4 3 # 6.5.4 Enroll wireless siren + * 0 1 2 3 4 5 + # + 5 # + 4 # 1 2 Delete wireless siren + 5 # Enroll wireless siren 6.5.4.
U ser 册 手 品manual 产 6.6.5 Set door bell + * + 0 1 2 3 4 5 + # 5 # + 1 2 5 # Enroll doorbell Delete doorbell 6.5.5.1Enroll doorbell Press[*] for 3 seconds Enter password + * + 1 # + 0 1 2 3 4 5 Please trigger doorbell Pressback key to exit. # + Please trigger doorbell 5 # + 5 # Enroll + successful # Note: can only learn a wireless doorbell, the trigger will be issued after the chink 6.5.5.
U ser 册 手 品manual 产 2.interior zone only trigger alarm when the zone is triggered under system at armed status. 3.delay and perimeter zone trigger alarm when the zone is triggered under system at armed or home arm status. 4.emergency zone, 24 hours zone, fire zone will trigger alarm when system at any status 5.wirelss zone can not set key zone type. When wired zone is set as keyzone, trigger the zone, system turn to disarm status. The zone restore, system turn to armed status.
U ser 册 手 品manual 产 10KΩ NC Z Z NO 10KΩ C EOL loop N/O wiring diagram C EOL loop N/C wiring diagram Example: set zone 35 as N/O loop type Press[*] for 3 seconds 0 1 2 3 4 5 Enter password + * Please enter the zone number to modify + Press confirm key to save, Pressback key to exit. + 3 + 3 5 + + # + 6 # + 3 # Please choose loop type: 1.EOL 2.N/C, 3.N/O Press confirm key to save, Pressback key to exit. # # 6.6.
U ser 册 手 品manual 产 2>EXIT-ENTRANCE single trigger model: trigger zone 1, zone 1 make alarm. Trigger zone 2 first, then during the period of related time trigger zone 1, do not make alarm. Trigger zone 2, then do not trigger zone 1 during related time, then zone 2 make alarm. 3> Dual trigger alarm mode: trigger zone 1 or zone 2 only do not make alarm. During related time trigger zone 1 or zone 2, then zone 1 or zone 2 make alarm.
U ser 册 手 品manual 产 6.7.1 Set timing operation Example: Set group No.3 as timing disarm at 8:30, and timing arm at 17:30 Press[* ] for 3 seconds Enter password + * 0 1 2 3 4 5 Please enter timing arm /disarm group number 1 7 3 0 + + 3 + # + # 7 # + 1 # Please enter timing arm time, 00 is invalid + time.Press confirmkey to save, pressback key to exit. Please enter timing disarm time, 00 is invalid time. Press confirm key to save, + press back key to exit.
User 册 手 品manual 产 For example: Set as password control output Press[*] for 3 seconds * Enter password + 0 1 2 3 4 5 + # 7 # + Please select programmable output port follow event 1.Follow alarm output 2.Follow arm output 3.Follow AC power fault output 4.Follow Communication fault output 5.Password control output + 5 + + 4 # # Hint: when setting as password control output, press key 5 for 3 seconds, then enter the user password, the programme output port will be open or closed.
U ser 册 手 品manual 产 Set GSM module [1]Set GSM disabled/enabled 1 # Please choose 1> enable GSM 2> disable GSM, Press confirm key to save, press back key to exit. [2]Set GSM [3] GSM signal [4] Set GSM bill in priority display reminder time 2 # Please choose 1> GSM in priority 2> PSTN in priority, Press confirm key to save, press back key to exit. 1 # 2 # The setting is saved The setting is saved 3 4 # The maximum signal intensity can be displayed in LCD is 31, press back key to exit.
User 册 手 品manual 产 6.9 Advanced setting options Without voice prompt, programme address and the corresponding options as below table.
User 册 手 品manual 产 LCD display direction M Programming address D Data Y Data bit Press key up and down to check and modify the different data of the data bit. 6.9.1 GPRS enable and disable(1. Enable 2. Disable default is 2 ) For example: set enable GPRS Press[*] for 3 seconds + Enter password * + LCD display 0 1 + 1 0 1 2 3 4 5 + Programming Data address + + # + 9 # # LCD display Hint: Priority to enable the GSM module before enable the GPRS 6.9.
U ser 册 手 品manual 产 6.9.3 Set sever port For example: Sever port as 80808 Press[*] for 3 seconds * Enter password + + 0 3 0 1 2 3 4 5 + # 8 0 8 0 8 + + 9 # + # + 9 # 6.9.4 Set user ID For example: User ID as 50505050 Press[*] for 3 seconds * Enter password + 0 4 + + 0 1 2 3 4 5 + # 5 0 5 0 5 0 5 0 + # User ID must be 8 bits 6.9.
User 册 手 品manual 产 6.9.7 Delay zone tone source options 1. Dingdong 2. Welcome 3. Recording 4. Didi For example : Delay zone tone source as recording Press[*] for 3 seconds * Enter password + + 0 7 0 1 2 3 4 5 3 + + + # + 9 # # Hint: In disarm mode, once delay zone triggered and above 4 voices will be generated. press key 4 for 3 seconds and input the user password can be open and close it.When the tone source is recording mode, the voice phone will not play the recording. 6.9.
User 册 手 品manual 产 6.9.11 Alarm event retain time When telephone line and GSM all fault, the alarm event will be retained in the preset time. Otherwise it will loss. After telephone line and GSM recovery, it will upload to the CMS. (default time is 10 mintus). For example: set the alarm information retention time is 255 minutes Press[*] for 3 seconds * Enter password + 1 1 + + + 0 1 2 3 4 5 2 5 5 + # # Retain time :1-255 mintus.Less than 3 bits high zero.
User 册 手 品manual 产 Chapter VII technical specification 7.1 General data 1.Power supply: 15V/2000mA 2.Built in rechargeable battery:11.1V/1000mah 3.System static current: <50mA(exclude wireless detector) 4.System alarming current: <300mA(exclude wireless high siren current) 5.System maximum output current: ≤100mA(supply wireless detector) 6.Frequency:433MHz/868MHz 7.Signal transmit distance: 100 to 150 meters (open area) 8.The method of alarming dial: DTMF GSM or GPRS 9.
User 册 手 品manual 产 Chapter VIII maintenance 8.1 Regular test Design of components of the system is to reduce maintenance cost, but still it is suggested that periodical check may be carried out. 8.2 The cleanliness of control main machine Main control panel may be stained by fingers or covered by dust after using for a while. Use soft cotton cloth or sponge to clean it, don't use any lubricant, liquid such as kerosene, acetone and strong gel which will damage appearance and the transparency of top window.
FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.