MR6034A UHF four antennas reader specification IMPORTANT INFORMATION REQUIRED BY THE FCC THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. FCC RF Exposure Statement The maximum output power is 16.79dBm at 902.5MHz (with 5dBi antenna gain.). The reading distance must be greater 20cm.
Catalogue 1. MR6034A READER SUMMARY ................................................................................................3 1.1 MR6034A READER APPLICATIONS .............................................................................................3 1.2 MR6034A READER FUCTIONS ....................................................................................................4 1.3 MR6034A READER SCANNER PARAMENTERS ............................................................................4 2.
1. MR6034A READER SUMMARY The product can be multi-protocol, quickly read, multi-tag read and four antennas outside.It can connect four flat antennas of different gains at most through high frequency cable, so as to extend the effective range and reduce hardware cost. • • The longest reading distance can be 12m;read quickly, can read the tag of moving sped 120km/h accurately. Has the functions of ID NO.
1.2 Mr6034a reader fuctions 1)Rouse tag: only the tag that is roused can be communicate with reader and prevent interference from other tags outside the system, so as to make the changing information between the system and tag reliable and accurate.。 2)Read tag data: not only can read the ID NO. of tag, but also can read the data of the appointed tag storage area; not only can read single tag data, but also can read multi-tag datas in the range of antennas wave.
2.1 Reader interface specification 2.1.1 RS232 The reader provides RS232 communication interface, ,so as to communicate with controllers(generally PC)The data format of RS232 is 8 data bits,one star bit and one stop bit,no parity bit;data rate can choose 9600,19200,57600 and 115200.RS232 interface supports reader parameters deployment, demonstration program and all the secondary development bag function of straight communication. 2.1.
RS232 wire or data 3. MR6034A reader installation MR6034A reader 3.
3.2 the fixation and height adjustment of the reader ¾ When frank fitting ,it demands that the crutch dia.of the reader 50 to 60mm while length2.2m Using stain steel material that more than 1.3m thick is the best choice. Fix the reader to the top of the crutch with the self-provided fastening pin in the casing of MR6034A reader .
4. MR6034A demo program instructions 4.1 RS232 port DEMO Reader demo program offer all operations and reader’frequency parmeters for tags.User can use the demo to evulate reader’funtions Reader demo program includes two parts: “DEMO.exe”and“MR915ApiV10.dll”.User should put these two parts in same documents items,then click “DEMO”,can run..
IP query:connect reader and computer toghter with RS232,choose”Serial Port”and COM,click”CONNECT”,then the IP column will show the IP address and port of that time after success. IP setting:connect reader and computer(RS232 AND RJ45),the left of the interface will show the IP address of that time,plswrite down the IP address in the “Gateway IP”that would be modified,click”SET”,then restart the reader after success. 4.2.2 RJ45 DEMO Explain Reader demo program includes two parts: “DEMO.exe”and“MR915ApiV10.
5. MR6034A sencondary development User can do secondary development for application software according to user’demands.We offer secondary development .can support VC++,VB,Dephi,C++Builder,detailed that you can reference (MR reader SDK instructions). This device complies with Part 15 of the FCC Rules.