Dear Customer: Many thanks for bought Marktrace device. Go through precuts user manual carefully before you operate. To make sure Marktrace device work correct. Any questions, please contact us. We welcome your feedback and comments. SHENZHEN MARKTRACE CO., LTD.
(Ver1.2) Disclaimer Martkrace reserve the right to update and modify this user manual. For the new documents may has no further notice. Don’t tear up the warranty label or take reader apart to repair by yourself, we reject perform warranty duties if this happened. Shenzhen Marktrace Co.,Ltd have trademark right on the trademark which in this user manual and receive legal protection. DO NOT make free with theses trademarks.
1 Matters need attention 1、 Dismantle and parts replace:Marktrace has no warranty duties on those faults which caused by dismantle and parts replace by customer .; 2、 Power supply:please use the power adaptor which alone with precuts to get power. If not may harm the products.; 3、 Falling damage:Mind parts damage by device falling, if this happens, turn off power immediately and connect the distributor or Marktrace customer service center.; 4、 Unusual condition:Away from fire.
2 Reader instruction 2.1 MR6100 Serial UHF reader introduction Model Description Parameter MR6111E Long range integrated reader 12dBi Gain antenna inside MR6121E Mid-range integrated reader 9dBi Gain antenna inside Photo 2.2 Reader instruction This products has the features like multi protocol compatible, multi-tag identify, multi-tag multi area read and write, fast reader speed, can connect to four antennas etc.
5、 Tag identify speed : Single tag 2000 times/minute , multi-tag 200pcs/second; 6、 Have RS232、RS485、 Weigand、TCP/IP、Relay etc output interface; 7、 Compatible with tag match function,Reader can identify the tag which match the condition or not identify these condition tags by setting the match conditions.; 8、Compatible with data cache function, Using FRAM (ferroelectric memory) which can save data when power down,memory capacity is 32KBytes, Can save 2200 pcs tag data in 12 Bytes data length. 2.
same time; 2、 Write tag:Can write the same data length in multi-tag’s same area.; 3、 Tag match:Can read match tag or dismatch tag via setting the match conditions; 4、 Make data communicate and change with the connection between standard communication interface and controller or PC,; 2.5 Reader technical parameter 1、 CompatibleISO18000-6B and ISO18000-6C(EPC-GEN2) protocol standard; 2、 Working frequency:fixed-frequency can choose ISM 902~928MHz (America)、stepped frequency is 500KHz;modulation mode is ASK.
3 Reader Structure and Interface Explanation 3.1 Reader Structure Explanation 1、 MR6111E、MR6121E integrated reader structure explanation 3.2 Explanation on the reader communication interface 1. RS232: the Reader provides standard RS232 communication interface as the output port for data modulation. RS232 has 8 data bits format: 1 start bit and 1 stop bit, no parity bit. The default baud rate is 115200 bps.
4. RS485:Reader provide RS485 communication interface(10、11 pin), work as data main output mode,also can connect with PC via serial port, use RS232-RS485 converter,in this way,RS485 interface support RS232 all supported functions; 5. Programmable output interface : Two sets TTL electrical level programmable output interface(1、2 pin),works as Wiegand output interface,default is high level(5V);one set relay interface(13、14、15 pin),relay default status is OFF and COM short circuit 6.
4 Quick Start Guide 1、 Connect antenna to reader’s antenna port,connect power adapter to reader and then power on,connect reader to LAN or PC by network cable; 2、 In PC open demo software“MR6100 Demo V1.0”,fill in reader IP address and click“Connect”to connect reader(reader factory default IP address: 192.168.1.200); 3、 In“Gen2 EPC MultiTag” page,click bottom right corner“Identify”button will start EPC tag query operation,see below: 5, Click “Stop” button to Stop identify operate.
5 Reader parameter configuration 5.1 Webpage configuration Reader connect to LAN through TCP/IP port,or directly connect PC,in PC IE browser input reader IP address ( reader factory default IP address: 192.168.1.
1)User can configure IP address、RF power、frequency、antenna port、applied mode、read card indicating etc.
6)Read tag data can be select buffer or directly output,data buffer adapt with power down save ferroelectric memory,storage capacity 32KBytes,when read data length is 12Bytes,can store more than 2200pcs tag data; 3、output configuration 1)In working mode configure, when select data output as directly output mode, user can configure output port; 2)Reader data output port have RS232、RS485、Wiegand、Ethernet and relay output; 3)Wiegand protocol support Wiegand26 and Wiegand34; 4)Relay close delay time configurab
All above configuration will be valid only after click left bottom button“set” button 5.2 Demo software Configuration 5.2.1 Reader connection Click MR6100Demo.exe software, input reader’s IP into the IP input box (Default IP: 192.168.1.200, Port: 100 which is fixed), then click ‘connect’ ICON, software information display box will display the reader’s parameter on the success connection. Below image demonstrate the success connection. 5.2.2 Antenna & RF Power setting 1 On MR6100Demo.
on RED ICON. Only the selected GREEN ICON port’s antenna works. 2、 On Integrated RFID reader and Desktop RFID reader, config and set one antenna port for the reader to work. 5.2.3 Frequency Setting On MR6100Demo.exe software's Setting interface, Query Reader’s Frequency on Frequency setting menu, North America Frequency (902-928MHz). Take below images for the reference. 5.2.4 Working Mode Setting.
5.2.5 Buzzer & LED Setting 1、On Setting interface’s Buzzer & LED Setting menu for Querying and Setting Buzzer & LED ON/OFF. Take below image for the reference. 2、After setting Buzzer & LED ON/OFF, Reader automatically reset, and need to reconnect the reader. 5.2.6 IP Address Setting 1、On setting interface’s TCP Parameter Setting menu for querying and setting reader’s IP, take below image for the reference.
6 Demo software demonstration 6.1 EPC Gen2 tag Demonstration 6.1.1 Multi tag Identify 1、On Gen2 EPC Multi Tag interface’s Identify menu for the Multi tag identify, and click Identify ICON to start the reading. EPC code, antenna number and tag reading times displayed on the interface info. box. On the interface bottom displays tag number, Peak reading rate, Read times, total reads, Average reading rate, and duration reading time. Take below image for the reference.
6.1.2 Multi Tag Read & Write 1、On Gen2 EPC Multi Tag interface’s Multi Tag Read menu for the Multi tag read, Multi tag reader is read tag’s RESERVE Membank, EPC Membank, TID Membank & USER Membank at the same time. The steps are: 1) select the reading Membanks, 2) select the start reading address and the reading word count (EPC tag’s unit is word), and then click ‘Read’ ICON to start the Multi-tag reading. Take below image for the reference.
4、Click ‘Stop’ ICON to stop the Multi-Tag encoding, at the bottom of the demo software display the Success encoding tag number, and tag encoding duration time. 5、In accordance with the EPC Protocol, On Multi Tag Read & Multi Tag Write, EPC Membank’s Start reading address and Start encoding address is from the EPC Membank’s Second word address. 6.1.3 Tag Filter On Gen2 EPC Single Tag interface’s Gen2 Select Config menu for the Tag Filter rule setting.
2、Match setting, reader reads and displays only the condition matched tag. 3、Mismatch setting, Reader doesn’t read and display the condition matched tag. 4、Empty the input value for cancel the Tag filter rule. 5、If setting EPC Membank as the Tag filter rule, the valid Word Addr is 2. 6、After set the EPC tag filter rule, this rule is valid for all EPC tag detect. 7、After set the EPC tag filter rule, this rule is valid for all the time unless the reader is power off or reset. 6.1.
Access Password, EPC Memban and USER Membank can be encoded with Access Password. 4)Lock forever, if the tag is set to lock forever, it can’t be unlock again. 6.1.5 EPC Gen2 Tag Read and write with Access Password 1、n Gen2 EPC Single Tag interface’s Gen2 Secured Read and Gen2 Secured Write menu for the EPC tag reader and write with Access password. Take below image for the reference. 1)Gen2 Secured Read with Access password 2)Gen2 Secured Write with Access password.
2、EPC Gen2 tag can’t be read and write if the tag is killed. 6.2 ISO18000-6B Protocol tag Demonstration 6.2.1 ISO18000-6B tag Identify On ISO 6B interface for the ISO18000-6B tag Identify. Click ‘Identify’ ICON for the tags Identify, and the software interface displays the ISO18000-6B tag’s UID code, Antenna No., and the read times. Click ‘Stop’ ICON for stoping the tag Identify. Take below image for the reference. 6.2.
6.2.
6.2.4 Single tag writing and write with UID 1、Single Tag operation interface,choose the data address you want to write in the ISO Write menu item,click“Write”button to write data; 2、When operate writing data with UID,except for inputting the single byte data that needs to write,it also needs to put the UID number of tag,choose the start address that want to write,click“Write With UID”button to write data; 6.2.
7 Reader struction and installation sketch map 1、 MR6111E、MR6121E integrated reader installation sketch map:
8 Secondary development User can make secondary development for reader application software if needing.
9 Common faults and exclusion methods Failure Description Simple exclusion methods ■make sure the power adapter indicator light is on Unable to start reader ■make sure the reader power interface is connected well Unable to connect ■make sure the reader IP address is correct reader ■make sure the network environment is good Reader is unable to ■make sure antenna ports are connected correctly identify tag ■make sure antenna power is not to be 0 No sound when ■make sure the buzzer is open reading tag ■make su
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.