DR600 , DR600-01
User Manual DR600, DR600- 01 Digital Repeater We are very grateful for your purchasing Kirisun DR600,DR600-01 digital repeater manufactured by Kirisun Communications Co., Ltd. We believe Kirisun DR600,DR600-01 digital repeater, which always incorporates the latest technology, brings great convenience to your life and work and meets demands for reliable communication.
Notice ◆ Please carefully read this instruction manual before using the product for your easy operation. We will consider that you have read this manual once you use the product. ◆ Please carefully keep this manual for future reference. ◆ In order to protect your legal rights from infringement, please carefully fill in the warranty card and claim valid receipt. ◆Kirisun and its authorized partners own the intellectual property of all the parts of this product (including accessories).
Safety Precaution ◆The radio can only be repaired or maintained by professional technicians. The user must not disassemble the radio at liberty. ◆The settings and installation shall be approved by local radio management department. ◆Lightning protection is required when installing the repeater antenna. ◆Please use qualified power supply, antenna, thunder preventer, feeder and other accessories during installation, otherwise the repeater may be damaged.
Contents 1 Unpacking and Checking ........................................................................................................... - 1 - 1.1 Accessories ........................................................................................................................ - 1 2 Overview .................................................................................................................................... - 3 - 2.1 Power Switch ....................................................
1 Unpacking and Checking Please carefully open the box and make sure the items listed below are included. For items missing or damaged during delivery, please contact the local dealers for help. 1.
Repeater: Power Cable: - 2 -
2 Overview - 3 -
No. Part Name 1 Handle 2 Fan 3 Indicator 4 Power Switch 5 Ground Interface 6 100-240V AC Inteface 7 13.
2.1 Power Switch Press this button to power on/off the repeater. 2.
2.2.1 PIN Description Pin Description PIN1 DC 13.6V Output PIN2 Ground Cable PIN3 Null PIN4 Null PIN5 Null PIN6 Null PIN7 External PTT Signal input, High level active .
PIN16 Null PIN17 Ground Cable PIN18 External Analogue Audio Input PIN19 Ground Cable PIN20 High level electrical signal output PIN21 Squelch is on when it is connected to PIN20 and it is used for testing PIN22 Null PIN23 Null PIN24 PTT output; used for bridge connection PIN25 Null PIN26 Null 2.2.2 External Interface Description • To Activate the External PTT Connect PIN7 and PIN20 of ACCY interface to activate the external PTT, and you can test the TX signal of repeater.
Connect PIN10 and PIN20 of ACCY interface. The repeater changes the IP address and gateway address to the IP on the label, but the data of them are not changed. After re-boot, the configured IP address and gateway address will be recovered. 2.
Indicator Description Power Indicator 3 Basic Operation 3.1 Power on /off Repeater When the repeater is off, press the power switch to power it on. When the indicator the system starts to operate, and the indicator or Press the power switch glows, will indicate the current work mode. to power off the repeater when it is on. 3.2 Voice and Data Transmission The TX frequency and RX frequency on the repeater channel are different.
dealers. One analogue channel or digital/analogue adaptive channel can edit one group of CTCSS/CDCSS codec list, and when CTCSS/CDCSS is received on this channel, the repeater will transmit the correspondent CTCSS/CDCSS codec list. 3.3 IP Interface Default IP address: 192.168.1.100. You can upgrade software, configure the programming parameters and perform extended development through this interface. 3.
software trying to connect to the same repeater, it shows busy network status on the second software, meanwhile, the connection button will pop up automatically, and you need to click it for re-connection. 3.5.1 Menu New: creates new channel information. The repeater creates new channel information configuration file and one analogue channel by default with default parameters. Open: open the file saved on the device. Save: saves information configuration on the current channel.
Group Call Hang Time: during group call on the terminal, if no PTT button is pressed on any terminals, the repeater will keep call hang time and does not accept signals of other group. If there is any one of the members press PTT button during the call hang time, the hang time will be counted again. After the call hang time is over, the call ends and the channel resources are released. Value range: 0~7000 milliseconds; step value: 500 milliseconds; 4000 milliseconds by default.
• Internet Settings Local IP:repeater IP address, such as 192.168.1.100. Subnet Mask: the repeater subnet mask in local area network, such as 255.255.255.0. Gateway: the repeater gateway in the local area network, such as 192.168.1.1. DNS:configure the domain name server or set it as 0.0.0.0. Networking Modes: supports three modes including: no network, as server or as slave device.
Message Delay Setting: the delay setting is used to prevent network latency. The user can set the delay time based on the network status. Value range: 60 milliseconds to 960 milliseconds; step value is 60 milliseconds. • Temperature Control Fan Control Mode: the fan can be turned on constantly or turned on automatically according to power amplification temperature.
CTCSS Frequency: when the CTCSS squelch mode is selected, you need to select one CTCSS frequency value, otherwise the call between two parties is not possible. Value range: 0~254.1Hz; step value is 0.1 Hz; default value: 67 Hz. CDCSS: if the squelch type is CDCSS or –CDCSS, you have to select one CDCSS value, otherwise the call between two parties is impossible. Value range: 0~777; step value: 1; default value: 023. Notice: (1)The squelch level is only applied to analogue channel.
XX”. Upgrade: you can download each function module from PC to repeater and configure with main parameters. Select the path for upgrade package before upgrade. 3.6 IP Connect* An IP connected system can be composed of multiple repeaters through network. This system includes one master device and multiple slave devices (32 members max.).
B. Transmission Failure Check if the frequency configuration between the portable and repeater is the same and whether their modes are matched. 5 Parameters Frequency Range: 136-174MHz,400-470MHz , AC: 100-240V@2.5A 50/60 Hz DC : 10.8-15.6V@15A DC Insurance: 13.6V15A AC Insurance: 2.5A 250VAC, 5x20mm Insurance Type: HRC ceramic, Time lag (T) Supplied Power: 200W TX Power: 40W(UHF) / 45W(VHF) Size: 482.
RF Energy Exposure Compliance ƽ Your radio is designed and tested to comply with a number of national and international standards and guidelines (listed below) regarding human exposure to radio frequency electromagnetic energy. This radio complies with the FCC RF exposure limits for occupational or controlled RF exposure environment and is authorized by the FCC for occupational use only.
Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Note:” Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.” This device complies with Industry Canada licence-exempt RSS standard (s).
- 18 -