Title: AJ102 Data Concentrator Unit User Manual Data Concentrator Unit Model No. AJ102 Version: 1.4 Release Date: 2018.09.11 Safety Instruction Ver. 1.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 2 of 23 Read all safety information and operating instructions before using the DCU to avoid personal injury. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 3. DCU working voltage should be less than 120% nominal voltage (120%Un). Long time over voltage may lead to damage the DCU. 4. Do not operate the DCU with wet hands. All Rights Reserved No part of this document can be reproduced or transmitted in any form or by any means without prior written consent of Shenzhen Kaifa Technology (Chengdu) Co., Ltd. Notice The information in this document is subject to change without notice.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 4 of 23 Content 1 OVERVIEW ................................................................................................................................................. 6 2 ABBREVIATION ......................................................................................................................................... 6 3 GENERAL DESCRIPTION ......................................................................................
Title: 8.4.2 AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 5 of 23 DCU Installation ................................................................................................................... 17 ANNEX 1 REFERENCE STANDARDS .............................................................................................................. 21 ANNEX 2 RF COMMUNICATION CHANNEL ................................................................................................
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 6 of 23 1 Overview The AJ102 data concentrator unit (DCU) is capable of providing automatic data collection and remote control of smart electricity meters in AMI system. As a part of AMI solution, the DCU is used for managing meter, monitoring meter work status, collecting and storing meter data, transferring the data to central system, and transfer the message/command from the central system to meters or vice versa.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 3 General Description 3.1 Front View and Rear View Figure 1a, front view. Figure 1b, terminal cover opened. 1. Optical port 2. Nameplate 3. Terminal cover sealing screws 4. RF antenna interface sealing screw 5. LED indicators 6. Main terminals Figure 1c, rear view. 7. 3G communication module 8. Auxiliary terminals 9. Device fixing hook 10. Device fixing holes 11.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 3.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 9 of 23 4 Function Characteristics 4.1 Clock Management DCU has a RTC which complies with IEC 62052-21/62054-21. At reference voltage and reference temperature (23°C), clock accuracy is better than ±0.5 s/day. The RTC supports leap year, day light saving time. In case of power off, clock of DCU is active for at least two years after manufactured with battery support. DCU automatically synchronizes its clock with SNTP server every day.
Title: AJ102 Data Concentrator Unit User Manual Daily profile data Last two days Energy load profile Last two days Power quality load profile Last two days Ver. 1.4 Page: 10 of 23 4.4.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 4.8 Self-diagnose and Working Status DCU self-diagnose the communication ports (i.e. 3G module, RF, RS485, optical port etc), clock.
Title: AJ102 Data Concentrator Unit User Manual Firmware Upgrade 20 Communica tion Event Meter Event 200 200 for each meter Ver. 1.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 13 of 23 5 Communication Interfaces The DCU provides following communication interfaces: Function Local WAN LAN Interface Baud Rate Protocol Optical port 9,600 bps DLMS/COSEM HDLC profile RS-232 115,200 bps 3G Downlink transfer: max. 85.6 kbps Uplink transfer: 42.9 kbps DLMS/COSEM TCP/IP Profile. RJ-45 Ethernet 10/100M DLMS/COSEM TCP/IP Profile.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: The 3G communication parameters are generally programmed in the factory. It is also possible to change the communication parameter remotely or locally. Refer to LED indicators chapter for the communication status indication. 5.2.2 Ethernet Communication DCU supports one Ethernet port which can also be used for remote communication. 5.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 6 Security 6.1 Physical Security The DCU has two seals for the terminal cover, one seal for the RF antenna box. It is impossible to access the DCU internal part unless physically and transparently destroy the seals and the DCU face or terminal cover. The DCU records the main cover removal event and terminal cover removal event in both power on condition and power off condition. The DCU detects the meter dismantle/removal event. 6.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 16 of 23 7 Transportation and Storage The DCU should be placed on pallet and the height should not exceed 5 layers. The storage condition should be clean, with an environmental temperature of between -25°C and +85°C, relative humidity of less than 95% and with an absence of rusty matter in the air. 8 DCU Installation 8.1 Installation Environment DCU should be installed at a dry and well-ventilated place.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 8.4 Installation Guide 8.4.1 What You Need To install DCU, you should prepare: Screw driver: FD3 screw driver for main terminal screw. Fixing screw and Hook screw: M5 slotted countersunk (flat) head tapping screw. Electric drill with M3 broach for metal meter box installation. Electric drill with M5 broach and plastic plug for concrete wall installation. 8.4.
Title: AJ102 Data Concentrator Unit User Manual A: Hook, Ver. 1.4 Page: 18 of 23 B: Fixing hole Step 3: Install RF antenna 1) Remove the RF antenna cover 2) Connect tightly the RF antenna to the RF antenna connector 3) Remove the cut-out of the RF antenna cover 4) Install the RF antenna cover, the RF antenna cable should pass through the cut-out 5) Fix the screw 6) Seal the RF antenna cover. Note: Before install the RF antenna, you may need to fix the RF antenna on the cabinet of the DCU.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 19 of 23 Step 5: Install 3G external antenna Tightly connect the external 3G antenna to SMA connector on the 3G module. Note: 1) It’s better to install 3G antenna without removing the 3G module from the DCU. 2) Before install the 3G antenna, you may need to fix the 3G antenna on the cabinet of the DCU. Make sure the 3G antenna is fixed at the bottom of the 3G module, and as show in figure shows are as follows.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 20 of 23 Step 7: Power on inspection After right connection of power wires, turn on the power. Inspect LED status according to chapter 4.10. 1) “PWR” LED should be on. 2) “WCSQ” LED should be on, or at least blink. 3) “Res.” LED should not be always on. 4) “RF” LED should not be always on. 5) “ALARM” LED should not be on.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: 21 of 23 Annex 1 Reference Standards No. Standard No. Title 1 IEC 62056-21 Ed. 1.0:2002 Electricity metering – Data exchange for meter reading, tariff and load control – Part 21: Direct local data exchange 2 IEC 62056-46 Ed. 1.1:2007 Electricity metering – Data exchange for meter reading, tariff and load control – Part 46: Data link layer using HDLC protocol 3 IEC 62056-53 Ed. 2.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.4 Page: Annex 2 RF communication channel Channel Frequency(MHz) Channel Frequency(MHz) Channel Frequency(MHz) 1 915.25 18 916.10 35 916.95 2 915.30 19 916.15 36 917.00 3 915.35 20 916.20 37 917.05 4 915.40 21 916.25 38 917.10 5 915.45 22 916.30 39 917.15 6 915.50 23 916.35 40 917.20 7 915.55 24 916.40 41 917.25 8 915.60 25 916.45 42 917.30 9 915.65 26 916.50 43 917.35 10 915.70 27 916.
Title: AJ102 Data Concentrator Unit User Manual Ver. 1.