User's Manual

UserManual
WirelessIntelligentThermometer
Model:JPD-TH100
Date of Issue: Mar. 10, 2017, Version: A/0
Technical SpecificaonsCleaning & Disinfecng
Care & Maintenance
Troubleshoong
Power supply mode Internal power source
Type B applied parts
CR 2032 buon baery
DC3.0V
Diameter:33mm; Height: 8.5mm
8.5g
2 years, producon dateonthelabel.
32.0°C ~42.0°C/89.6 ~107.6
±0.1°C/±0.2°F
10m
Classificaon
Baery specificaon
Working voltage
Dimensions
Weight
Service life
Temperature range
Measurement accuracy
Transmission distance
Operang environment
Transportaon &
storage environment
C~40°C; ≤80% RH; 70kpa ~ 106kpa
-20°C~55°C; 10% RH~93% RH; 50kpa ~ 106kpa
Store in well-venlated room without aggressive gas.
(Notes: Do not soak intelligent thermometer in liquid for cleaning or disinfecng.
Do not allow liquid to penetrate the intelligent thermometer.)
Cleaning:
Wet the clean so cloth with a small amount of water or mild detergent, wring
it out and wipe the dirty parts or the sensing parts.
Acid detergent or alkaline detergent is prohibited to use.
Disinfecng:
Wet the clean so cloth with a small amount of medicinal alcohol (concentraon:
75%), wipe the intelligent thermometer and the sensing parts before and aer use.
Put the intelligent thermometer in clean storage box and store the box in
well-venlated and dry place aer use.
Take out the buon baeries of intelligent thermometer if it want be used for
a long me.
In order to avoid the damages on parts, prevent the intelligent thermometer from
falling off and violently crashing during use. Do not clean the intelligent
thermometer with acetone, gasoline and other strong solvents.
Problem
Fail to connect
to
smartphone
Possible reason Soluon
A. The buon baery is run
out of power;
B. The baery is inserted in
wrong poles.
A. Replace the baery.
B. Insert the baery based on
the right poles.
Shenzhen Jumper Medical Equipment Co.,Ltd.
EC
REP
Wellkang Ltd
Suite B, 29 Harley Street, London W1G 9QR,UK
D Building, No. 71, Xintian Road, Fuyong Street, Baoan,
Shenzhen, Guangdong, China.
Tel: +86-755-26696279
Fax: +86-755-26852025
Website: hp://www.jumper-medical.com
Frequency Range
2402-2480MHz
Max.RF power
- 1.9dBm
RF Exposure Informaon and Statement :
This equipment complies with FCC RF radiaon exposure limits set forth for an
uncontrolled environment.
This device complies with part 15 of the FCC rules Operaon is subject to the
following two condions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operaon.
NOTE: The manufacturer is not responsible for any radio or TV interference
caused by unauthorized modificaons to this equipment. Such modificaons
could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instrucons, may cause harmful interference to radio communicaons.
However, there is no guarantee that interference will not occur in a parcular
installaon. If this equipment does cause harmful interference to radio or
television recepon, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separaon between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help
- This device and its antenna(s) must not be co-located or operang in conjuncon
with any other antenna or transmier.

Summary of content (2 pages)