Installation Instructions

SAFETY INFORMATION
Read all instructions before beginning; Save these instructions for future use.
To reduce the risk of fire, electric shock, or injury to person(s), pay close attention
to this manual and stay within its guidelines when using this product.
This receiver is rated IP20; avoid sun and moisture exposure.
Avoid using receiver in areas where extreme hot, cold, dust, or humidity exist.
This receiver is suitable for indoor, dry locations only.
• Always be sure to mount this controller in an area with proper ventilation to avoid
overheating. This product has an operating temperature range of -10°C to 40°C.
• Never connect any cables while power is on and always ensure correct connections
to avoid short circuits prior to switching on. Ensure all wires and cables are secured
tightly in the connector prior to operation.
For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals or abrasives.
This receiver is rated for 12-24V DC input with a 0.5W minimum load requirement.
This receiver has a maximum output of 72W (12V DC) or 144W (24V DC).
These products may represent a possible shock or
fire hazard if improperly installed or attached in any
way. Products should be installed in accordance
with these instructions, current electrical codes,
and/or the current National Electric Code (NEC).
This receiver requires a 12-24V DC power
supply (ADPT or LED-DR series hardwire drivers
or PS series plug-in drivers recommended, sold
separately). Disconnect supply power at the source
prior to installation.
Page 1 of 2©2019 American Lighting, Inc. REV1914 www.AmericanLighting.com 11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
WARNING
WARNING
SPEKTRUM Smart Receiver
INSTALLATION INSTRUCTIONS
SPK-REC-5CH
12-24V
1. Determine desired location of receiver. 3M® tape (included)
may be utilized to secure receiver in place.
2. This receiver has 5 x 6A current output terminals that can be used
in conjunction with the Spektrum App or SPK-CTRL-W-RGBTW to
control single color, Tunable White, RGB, RGBW, and RGB+Tunable
White fixtures. Wire the receiver to a fixture by following the fixture’s
instructions manual and wiring diagrams below, ensuring to match polarity (wiring varies depending on product) using the screw-down terminal
ports. Connect fixture prior to bringing any power to the system. (See Figures 2-6) Continued on back.
CONNECTING POWER TO THE RECEIVER (See Figure 1):
This receiver requires a 12-24V DC power supply (ADPT series
hardwire drivers or PS series plug-in drivers recommended, sold
separately). Disconnect power at the source prior to installation.
1. Ensure all wiring connections to fixtures are made prior to
connecting power to smart receiver. See “Installing & Wiring Smart
Receiver” with Figures 2-6.
2. When using a hardwire driver, make connections according to
polarity using the screw-down terminal ports (+ to + and - to -).
3. When using a plug-in style driver, insert the male DC connection
from the driver into the female DC connection of the receiver.
4. Connect the 12-24V Driver to a 120V power source according to
power supply installation instrucitons.
HARDWIRE DC PLUG-IN
12-24V
DC
+
-
FIGURE 1
INSTALLING & WIRING SMART RECEIVER (See Figures 2 to 6):
FIGURE 3 - Tunable CCT (3-Wire) Wiring Diagram
FIGURE 2 - Single Color (2-Wire) Wiring Diagram

Summary of content (3 pages)