Smart Plug
Quick Operation Guide
Metering
Technical Parameters
Product Description
Product Details
Click add icon in the app to enter into networking mode.
1 2 3 4
*Please read the user manual carefully before operation.
The guide picture is for reference only, please in kind prevail.
Supply Hub
LED Indicator
Power Switch/
Networking Button
This is a smart m plug, adopts flame
retardant housing shell, and super low power
consumption ZigBee wireless transmission
technology. ZigBee
, voltage, current overload protection.
ug and play, easy to install.
etering
power metering
It can be used as wireless
repeater, to extend wireless communication
distance. It supports and
timing switch functions. With the function of
power
Pl
1.Working Voltage: AC100V~240V (full voltage range)
2.Average Power Consumption: 0.5W
3.Maximum Load: 3000W
4. Metering Voltage Range: 100VAC-240VAC
5.Metering Current Range:<16A
6.Metering Power Range: <3000W
7. Wireless Networking Distance: Up to 100 meters
( in open area )
8. Working Environment: -10 ~ +50
9. Working Humidity: 95%RH
10. Networking : network
11. Dimensions: 79.6*67.9*72mm
ZigBee
Press and release the power switch (networking button) to
enter into networking state, LED Indicator flash for 3 seconds
(5 times per second) if networking successfully, then APP
will prompt “networking successfully”.
1.Enter into the device list of APP, then long press the
device needed to delete, APP interface will prompt “delete
device”, click to delete device.
2.Long press power switch(networking button) for 5 seconds
to disconnect network. LED Indicator flash slowly for 3
seconds(2 times per second), which indicates network
disconnecting successfully.
Delete sub device
Description of LED Indicator Status
Green
LED
Flash for 3 seconds if networking successfully (5 times /
second).
1.Flash slowly for 3 seconds(2 times per second) if network
disconnecting successfully.
2.Long press power switch(networking button) for 5
seconds, green LED flash slowly for 3 seconds(2 times
per second) if network disconnecting successfully.
State
Light
Light on: Plug turned on Light off: Plug turned off
6 7 8 9
Statement
*Instruction is for reference only, please prevail in kind.
*Because of the updating of the technology, the final
interpretation right owned by factory, if there are any
inconformities when using this products under this instruction.
Please choose proper plug type
according to your need.
!
US Standard Smart Plug
Plug the Smart Metering Plug into the p to enter into
Ad-Hoc networking state (networking state will befinished
a minute later), the interface will prompt “networking
successfully”.
lug
5
Networking 2:
Manual networking
Networking 1:
Ad-Hoc networking
The APP interface will show the power of the appliance and
record the power consumption after appliance is plugged into
the smart plug.
Power on/off: After pressing p ,
blue LED keeps on and supply hub will be powered on;
Press p
ower switch/networking button
ower switch/networking button again, blue LED turned off,
supply hub will be powered off.
10 11
UK Standard Smart Plug
Chooseable Plugs
It is suitable for table lamp,
TV, air-conditioner, refrigerator,
electric fan, coffee machine,
bread machine and some other
household appliances to meter
power consumption.
HS2SK-E-US
FCC Warning:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
o Reorient or relocate the receiving antenna.
o Increase the separation between the equipment and receiver.
o Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
o Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by
manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
To comply with FCC RF exposure compliance requirements,this grant
is applicable to only mobile configurations. The antennas used for this
transmittermust be installed to provide a separation distance of at least 20 cm
from allpersons and must not be co-located or operating in conjunction with any
otherantenna or transmitter.