MMC-2611D User Manual
Contents Contents ..............................................................................................2 1. Summary .........................................................................................3 2. Appearance......................................................................................3 3. Parameter ........................................................................................4 4. Main Functions ..........................................................................
1. Summary MMC-2611D works with all MMCall call buttons. It sends alphanumeric message to pager MMC-NC-8E. The functions are: wireless alphanumeric message paging, wireless deletion, duty repage, dispatch, urge dishes, monitoring function, USB data download and program update etc. It is suitable for restaurants, hotels, banks, bars etc. 2.
3. Parameter 3.1. Parameter Category Parameter Dimension 200mm * 173mm *37mm Power supply 12V/ 1.5A Outside Indicator Power supply,RX,TX Configurable 462.750MHZ, 462.775MHZ, 462.800MHZ, transmitting frequencies 462.825MHZ, 462.850MHZ, 462.875MHZ, 462.900MHZ, 462.925MHZ Receiving frequency 433.500MHZ Paging No. in cache 40 Repage No.
Temperature -30℃— +65℃ Table 3.1 Paging host parameter list 4. Main Functions Main functions are as following: 1. Wireless receiving function. The host can receive the signals from call button and palm transmitter with feature code, and transmit the message to corresponding pager. 2. The pager has to be MMC-NC-8E, which can display numeric and english message. 3. Text preprogrammed function. The paging unit, such as, table, room, bed etc.
7. Monitoring function. Connected directly with the computer through USB interface, it can monitor the messages from call buttons and palm transmitters for evaluating staff’ working efficiency. If the installation position of the host can not be connected with the computer, the monitor box can be used for the monitoring function. 8. USB data download and upload , program update function available. 5.
5.1 Function Introduction The software interface as picture 5.1 shows, mainly includes pager list, palm transmitter list, call button list and manual send data. In the setup column, there are file, system setup, read data, download data. Picture 5.1 TA Software Interface 1、File As picture 5.2 shows, it’s mainly the database operation, including New file, Open, Save as, Delete and Exit. Notes: There should be a database while using the software.
Picture 5.2 File 2. System Setup System setup including initialization, host parameter, program update, call type registration and pager check time. Picture 5.3 System Setup (1)Initialization It will initialize all the host parameters. (2)Host Parameter Host parameter as picture 5.4, room No.
Repage setup, it can setup the pager and its director repage times and interval. Transmission mode, there are two modes: inner transmission mode and 485 output, this is valid only for CA. For TA, only inner transmission mode. Picture5.4 Host Parameter Setup (3)Pager check time It can check the pagers’ time. Notes: you need to setup group ID, the default ID is 0. (4)Call Type As picture shows, call button type setup, is to edit the multi-key buttons while registering them.
preprogrammed type. E.g. The key quantity of E3 button is 3 key, and the key value 1,3,5 is chosen, after you press the call button, the host will automatically list the message key 1,3,5. 3 Read Data Read those already programmed or downloaded data. If no download, then data read is empty. Picture5.
remember to download the data to the host. The host won’t automatically update the data. Picture 5.5 Download data Download palm transmitter information: a)Urge dishes mode setup: (1) Use the urge dishes mode: tick it, this function can be used. (2) Numeric to English: tick it, the call button No. will be transferred to english name while sending the message. (3) Message prefix and suffix: if tick “Use the urge dishes mode”, when press button No.
Notes: While setup, input any number on the palm keypad and press# to send it b) Dispatch Mode Setup: (1) Use dispatch mode: if tick it, this function can be used. (2) Numeric to English: if tick it, the call button No. will be transferred to its relative english name. (3) Prefix and suffix: if tick “Use dispatch mode”, when press button No. XX+message content through the palm transmitter to dispatch, the host will automatically organize the message and send, the format is: prefix+ call button No.
5.2 Edit Function 5.2.1 Pager Registration 信息机登记如图 5.6 所示,传呼号为信息机编号,从 0~199 之间, 地址为信息机地址,该地址要与手表信息机地址相同,地址范围为 8~2097152 之间,如果选择地址码自加 1,则在添加上一个信息机后 地址将会被自动加一,备注部分为选填部分,主要用来提示使用者每 个信息机的功能与名称。Pager list as picture 5.6, No. is the pager No., which ranges from 0~199, ID code is the pager ID, which should be the same as the one in the pager; pager address ranges from 8~2097152. If you choose automatically added one, then after you add one pager ID, it will automatically add one.
Picture 5.6 Pager List 5.2.2 Palm Registration As picture 5.7, this part is for the customers who use palm transmitters. The palm No. for TA is 0~9, for CA is 0~99. There are two ways to add feature code: if automatically add one is chosen, you can manually input the feature and click add, if not chosen, after press Add, within 5 seconds, edit any message on palm transmitter and send it, then the software will automatically add and decode this palm’s feature code.
Picture 5.7 Palm Transmitter List 5.2.3 Call Button Registration In call button registration list, there are manual and automatic registration. Manual Registration needs to input the feature code manually while automatic registration will automatically upload the feature code. Button No. is from 0-1999, name means the name of room where the button locates or where to serve. After registration, the message content can be edited.
5.8 Call Button Registration 5.2.4 Manual Send Data Manual send data is for the computer to control and send messages. Pager No. And paging message can be input and edited by the software. After click send, if there is successful prompt, it means this edited message is valid, otherwise invalid. Pager No. is the pager content edited by the software, which needs to be downloaded to the host then it can be used. That is while using the manual send data, please make sure there exists this pager No.
5.2.3 Data Download 1. Pager parameter Download pager parameter 2. Call button parameter Download call button parameter 3. Palm transmitter parameter Download palm transmitter parameter 4.
6. Usage After programming all the data, please download it to the host, then it will work. 1). Normal call: Press CALL on the button, the host light will shine after receiving the signal, then read the edited text message and transmit it to the relative pager. 2). Delete call Press CANCEL on the button, with the condition that the host has already preprogrammed with the CANCEL function. Then it will cancel the message in the pager. 3).
4). Send message through software Open the software, input the pager No. and the message needs to be sent, the length of the message is 48 digits or letters, then click send, if the software appear a successful prompt and the TX light of the host is on, which means the message is sent successfully. The pager will receive messages successfully. 5). Usage of palm transmitter Urge dishes and dispatch function can be realized by palm transmitter. a.
finishing upgrade. During the upgrade process, remember not to cut off the host power supply, otherwise it will effect the upgrade. 7.
The transmission distance Check the RX and TX antenna are in a opposite is too close position If there are electronic wire around the TX antenna, please keep the electronic wire far away from the antenna If the TX antenna is close to the metal, please keep the antenna far away from the metal 8. FCC Important Note FCC Part 15.19 Warning Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
FCC Part 15.105(b) Warning Statement NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
and operated with a minimum distance of 20 cm between the radiator and any part of your body.