BIGTIDE SERVICE DOCUMENT DVI Splitter Amplifier DS01 User’s Manual Preliminary version Copyright © 2012 SHENZHEN BIGTIDE TECHNOLOGY CO.
BIGTIDE DS01 V3.0 User’s Manual Contents 1. INTRODUCTION ................................................................................2 2. SAFETY PRECAUTIONS...................................................................2 3. TECHNICAL INFORMATION ..........................................................4 3.1 POWER SUPPLY .....................................................................................................4 3.1.1 AC power input .......................................................
BIGTIDE DS01 V3.0 User’s Manual 1. Introduction This manual describes the safety precautions, specification, operation, installation of the Bigtide DS01 DVI Splitter. The BigtideDS01 is a DVI Splitter with one input and four outputs. The DS01 distributes a single DVI-D input to four DVI-D outputs. The DS01 has DDC functions by itself. The DS01 is able to switch DDC automatically according to the preset priority.
BIGTIDE DS01 V3.0 User’s Manual Danger There is a danger to life if the warning information is not observed. Severe personal injury or damage to property may occur. 1. Do not open the unit yourself, because certain components inside the units are at high- voltage. 2. Only use a perfect power supply cable, because a damaged power supply cable may result in a fire or electric shock. 3. Only use the same type of fuse 3.15A/250V 4.
BIGTIDE DS01 V3.0 User’s Manual 3. Technical information 3.1 Power supply 3.1.1 AC power input Input Voltage : AC100-240 V± 10% Current (max) : 0.35A (without AC power loop through output) : 2A (with AC power loop through output) Frequency : 50/60Hz ± 3Hz Power Consumption : <20W (without AC power loop through output) 3.1.2 AC power loop through output Output Voltage : AC100-240 V± 10% (Equal to input) Current (max) : 1.65A Frequency : 50/60Hz ± 3Hz (Equal to input) 3.
BIGTIDE DS01 V3.0 User’s Manual IN P U T D V I-D A C PO W ER OUTPUT O U T L E T 3 P IE C T Y P E GND A C P O W E R IN P U T IN L E T 3 P IE C T Y P E REAR PANEL Figure 2 3.2.1 Signal specifications Item SPEC Digital Signal Input DVI-D Input DVI-Digital DDC via DVI Digital Signal Output DVI-D Output DVI-Digital DDC via DVI 3.2.2 DVI output +5V Pin 14 load capability +5V load capability: Max. current 600mA for each output DVI port. 3.2.
BIGTIDE DS01 V3.0 User’s Manual 3.3 Product features Specification Item Digital Input Input Signals Output Signals Horizontal frequency 30kHz -82kHz Vertical frequency 50.0Hz - 85.0 Hz (Non-Interlaced) Video Signal Digital Video Sync. Signal TMDS Pixel Clock 25.0MHz-165.0MHz Maximum data rate 1.65Gbps Input connector DVI-D Connector Horizontal frequency 30kHz -82kHz Vertical frequency 50.0Hz - 85.0 Hz (Non-Interlaced) Video Signal Digital Video Sync. Signal TMDS Pixel Clock 25.
BIGTIDE Environment Condition DS01 V3.0 User’s Manual Plug and Play VESA DDC2B Operating temperature 0~45 degree C Operating humidity 20%~85% (without condensation) AC 100-240V 50/60HZ ≤ 0.35A (without AC power loop through output) Input Voltage AC 100-240V 50/60HZ ≤2A (with AC power loop through output) Power Supply Accessories Power Consumption <20W (without AC power loop through output) Input Connector IEC320 C14 Output Voltage AC100-240V, 50 / 60Hz; ≤1.
BIGTIDE DS01 V3.0 User’s Manual 3.4.2 Transport and storage (packed) Ambient temperature range -20 -- +60℃ Temperature gradient Max. 10℃/h, no condensation Humidity 10%~95% 3.4.3 Mechanical requirements Packed unit Shock Class 2M2 according to IEC721 Vibration Class 2 according to IEC68-2 3.4.4 Drop Test (packed) According to IEC68-2 Position Height Corner 1 100cm Edge 3,2,4 100cm A,B,C,D 100cm E 100cm F 100cm Surfaces (Cushion should be changed to new one.
BIGTIDE DS01 V3.0 User’s Manual Figure 3 3.4.5 Safety specifications Safety standards EN60601 Approvals CCC, CB Conformity CE 3.4.6 Electromagnetic compatibility IEC60601-1-2 EMC CISPR22 /24 CLASS B FCC Part 15 CLASS B 3.4.7 MTBF 100000 hours 3.4.
BIGTIDE DS01 V3.0 User’s Manual 3.5 MECHANICAL SPECIFICATIONS 3.5.1 Outline dimensions & weight Figure 4 Item Size of set Set Width 220.00mm Depth 179.80mm Height 44.00mm Housing components Aluminum Ventilation slots In two sides. Connection panel At rear and front Net weight Approximately 2.
BIGTIDE DS01 V3.0 User’s Manual 3.5.2 Package dimension and weight H D W Figure 5 Outer size of box Gross weight Width (mm) 450mm Depth (mm) 350mm Height (mm) 100mm Approximately 5.0 Kg 3.5.
BIGTIDE DS01 V3.
BIGTIDE DS01 V3.0 User’s Manual 4. Connections and start-up Caution In order to ensure safety operation of the equipment, close attention must be paid to the information contained in this User’s Manual as well as the warnings in section2 “safety precaution”. DDC switching 1. The unit has DDC functions by itself. 2.
BIGTIDE DS01 V3.0 User’s Manual Rear panel IN P U T D V I-D GND A C PO W ER OUTPUT O U T L E T 3 P IE C T Y P E A C P O W E R IN P U T IN L E T 3 P IE C T Y P E REAR PANEL Figure 17 DVI-D signal input Equalizes the DVI input, ensuring signal integrity. AC power input and AC power output AC 100-240V 50/60Hz GND Protective earth Note 1. Protective earth must be connected with PE cable for safety. 2. When AC power output is used, the output current should not exceed its maximum value.
BIGTIDE DS01 V3.0 User’s Manual In order to start the unit, the following steps should be carried out in the given sequence. 4.1 Connecting the power cord and its bracket Caution 1. 2. 3. 4. 5. Use a power cord with PE conductor corresponding to the safety requirement of the respective country of use. Remove the machine screw over PE sign, and then fix the PE cable on the housing of the unit with the machine screw. Put the power cords on the power cord bracket.
BIGTIDE DS01 V3.0 User’s Manual 3. Power on the unit and the desired display devices. 4. Power on the video source device. Note DDC communication is between the video source device and the desired display device connected to the DVI output connector of the highest DDC priority. 5. Fault diagnostics Fault Cause Remedy operation LED off Broken fuse Inform servicing department. Power cord not inserted or incorrectly inserted Insert power cord.
BIGTIDE DS01 V3.0 User’s Manual Repairs Please contact your distributor from whom you originally purchased the product. Environmental protection When disposing of the device, the requirements and laws in the respective country must be observed. Contact address Name of Manufacture: Shenyang Torch-Bigtide Digital Technology Co., Ltd. Address: No.18-8B, Yaoyang Road, Huishan Economic Development Area, Shenbei New District, Shenyang, China 110164 Person to be contacted: Mr.
FCC 6WDWHPHQW Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.