TECHNICAL MANUAL (ver.2.1) Plasma Display: PDP-V401/V401E Ceiling-suspension metal fixture for plasma display: PDK-4001 PDK-4006 PDK-4002 PDA-4001 PDK-4003 PDA-4002 PDK-4004 PDP-S01-LR PDK-4005 This manual gives precautions, general information, and examples for installation and handling of the plasma display and its metal fixtures. Carefully examine the structure, material, strength, and environmental conditions for the site at which the display is to be installed before selecting an installation method.
Contents Features ................................................................................................................................................................. 4 Specifications ......................................................................................................................................................... 2.1 List of specifications ................................................................................................................................... 2.
Contents 4.10 Infrared reduction filter: PDA-4001, protective filter: PDA-4002 .............................................................. 90 4.10.1 Specifications and features (infrared reduction filter: PDA-4001) ...................................................... 90 4.10.2 Specifications and features (protective filter: PDA-4002) .................................................................. 91 4.10.3 Assembling and installing the metal fixture and mounting the plasma display ..................
Features Features and functions of the plasma display (PDP-V401/V401E) ¶ Materialization of high luminance (400 cd/m2) Industry-leading luminance, equal to that of 30-inch class CRTs, is achieved by optimizing panel cell-structure. ¶ Sharp picture quality Eight-bit (256-color) and full-color (16,770,000 colors) display, with Pioneer's unique pseudo-contour-reducing technology that reduces plasma display noise. ¶ Thin and lightweight: 88 mm in depth and 30.
Features 5
List of specifications 2.1 List of specifications Light emission panel ...... 40-inch plasma display panel Aspect ratio ............................................................. 4:3 Applicable sources 1 Video system: NTSC No. of pixels ................... 640 × 480 (adaptable to VGA) Pixel pitch 2 Computer system 1. Resolution ........... 1.26 (horizontal, RGB trio) × 1.26 (vertical) mm No. of gradations ................................
Outline drawing 2.2 Outline drawing Plasma display main body weight : 30.8 kg <31.6 kg> Material : Front - Plastic, Back - plate Treatment : Front - Leather satin gray paint, Back - Semi-matte black paint Packing specifications - See “3.3.2 Unpacking” > shows the PDP-V401E. : Location of center of gravity 24 24 107 φ12 (the opening for infrared remote control signals) 202.5 •< 14 14.
Part names 2.3 Part names STANDBY /ON 1 2 ˚( INPUT 3 MENU 4 ADJUST 5 SET 6 (The terminals and power supply section are located at the back of the plasma display main body.) 7 8 9 OFF RGB-2 ON 75 (Ω) 2.2k G ON SYNC 0 VD SYNC - = ~ ! @ HD B G R C (H/V SYNC) RGB-1 (ON SYNC) Y/C # $ % Y OUT VIDEO IN ^ & * RS-232C 1 STANDBY/ON indicator The switch lights in RED for STANDBY and GREEN for ON mode.
Remote control 2.4 Remote control Power button Turns power on or off. VIDEO button Sets Input Function to VIDEO Input. MENU button Used to switch the menu screen and normal screen. ADJUST button Used to adjust images. STANDBY/ON VIDEO Y/C INPUT SELECT RGB 1 RGB 2 MENU Y/C button Sets Input Function to Y/C input. RGB 1 and 2 buttons These buttons set Input Functions to RGB 1 (BNC terminal) and RGB 2 (Mini DSUB terminal), respectively.
Installation environment 3.1 Installation environment The plasma display and special metal fixture must be installed after careful discussion with the building owner and manager of the building. Never undertake installation without careful consideration of the consequences. In addition, contact the contractor responsible for building construction and interior structure design and confirm the structure and safety of the building.
Installation environment 9) Temperature and humidity The installation site should conform to the following temperature and humidity conditions: • Operating temperature range: 0 to 40 °C (Depending somewhat on installation conditions, see descriptions of special installations and methods for installation of the standard metal fixture.
Installation conditions 3.2 Installation conditions 3.2.1 Radiation This display comes with multiple ventilation holes for efficient radiation of heat. Avoid blocking any of these holes. Ventilation holes are indicated by arrows in the following drawing. Five fans Side slits Side slits Air flows out through five of the ventilation holes and flows in through the other holes. For special installations, such as wall-hanging or embedding, additional restrictions apply concerning operating temperature.
Installation conditions 3.2.3 Installation position We recommend using the metal installation fixture made by Pioneer. When using a different fixture, use the M8 bolt hole provided on this display to mount the fixture to the display. Remove the hole rivets on the back of the plasma display, if necessary for the particular fixture. Tighten bolts with a force of 60 kg.cm or less. Overtightening may damage the blind nuts. • The following figure indicates mounting holes that can be used.
Installation conditions We recommend mounting at a minimum of 4 points, and at 6 or 8 points as shown below if possible. Avoid mounting the display with the particular 4-point scheme shown below. Mounting method — bad example Mounting method — good example A. 8-point mounting B. 6-point mounting (Do not block ventilation holes.) C. 4-point mounting (Metal fixture is mounted vertically.) (Do not block ventilation holes.) D. 4-point mounting (Metal fixture is mounted horizontally.
Installation conditions 3.2.4 Strain on surface where equipment is installed 1 This display uses glass in its display section. When using a third-party metal fixture, check that strain is 1 mm or less by the following method. 2 Tightly fit a thread using a force of φ 0.1psi or less diagonally through the mounting bolt openings on the mounting surface, as shown in the drawing. 3 Measure distance L of the intersection of the strings in the center section.
Installation procedure 3.3 Installation procedure 3.3.1 Precautions for transportation 1 Use two workers to move packages. Do not grasp the PP band during transportation. The band may snap and result in injury. 2 For transportation and storage, keep the package horizontal. Do not stack packages longitudinally or laterally. If packages are transported or stored while longitudinally stacked or laterally stacked, the company is guarantee will be invalidated.
Installation procedure 2) Procedure for unpacking 1 Remove the PP band. 2 Slowly lift and remove the upper carton. 3 Remove the instruction manual (7 and 8), accessories (9), and stand (2), affixed to the upper pad with tape. Caution: If the upper pad (3) is removed before first removing these items, the items may fall and damage the product. 4 Remove the upper pad (3). 5 Remove the corner pad (5). 6 Remove the mirror mat (4). 7 Remove the product. (Requires two workers to remove the set.
Installation procedure 3.3.3 Wiring 1) Power source connection • Refer to Power cord connection on page 24 <36, 82> of the instruction manual. • For power source capacity, see the description given in “3.1 Installation environment, 11) Power requirements” in this manual. 2) Signal cable connection (1) Connecting to a PC • See the description given in Connecting to a PC , on pp. 19 to 20 <26 to 29, 72 to 75> of the instruction manual.
Installation procedure 19
Special installations (Fixing on a structure) 3.4 Special installations This display may be installed in several different positions, including wall-hanging and wall-embedding. Conditions, including temperature, may restrict the use of certain positions or installation methods. Consider installation methods and conditions, and see the description given in “3.1 to 3.3” in this chapter. All the measurement conditions in this manual are set in conformity with the following: • 100% white light is applied.
Special installations (Fixing on a structure) Example 1: Example 2: Beams Ambient temperature requirement: 0 to 40°C Beams Ambient temperature requirement: 0 to 40°C Example 3: Example 4: Mount the display with the fans on the upper side. Ambient temperature requirement: 0 to 35°C Ambient temperature requirement: 0 to 35°C 21
Special installations (Wall hanging) 3.4.2 Wall hanging This display may be wall-mounted. Since this form of mounting affects ventilation patterns inside, observe the following requirements: 1 When mounting plate metal, avoid blocking any ventilation holes. Use plate metal of the size indicated in the following drawing. 2 Provide space for adequate ventilation between the wall and the display.
Special installations (Wall hanging) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installations (Wall embedding) 3.4.3 Wall embedding This display is designed to accommodate embedding in a wall. Note that the allowable range of outside-air temperature depends on the installation conditions. Please observe the following requirements: 1 If the unit must be embedded in the wall, you must not block the side slots of the unit. Avoid blocking the ventilating holes in the rear as much as possible. Never block the side slots.
Special installations (Wall embedding) (2) When there is open space behind the wall and the angle (shape) as shown in the figure can be maintained on the wall back: X MAX 20 mm 30° 30° 30° Y Exhaust If the back of the wall is tilted at 30 °C or less, the X, Y space temperature may be set to a limit of 40 °C, regardless of wall thickness. 30° Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts.
Special installations (Wall embedding) (3) When the back of the wall is in a closed space: Exhaust fan (air flow rate: 2 m3/min or more) 70 mm or less (on both left and right) X MAX. 20 mm (on both left and right) C Intake port A C Flow of air from the air conditioner \ Y B \ Exhaust A A 100 mm 100 mm B A Operating this display in confined spaces is not recommended.
Special installations (Wall embedding) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Ceiling suspension (using wires)) 3.4.4 Ceiling suspension (using wires) C A B D When suspending the display by wires, use a combination of two mounting rows, as shown in the diagram above (rows A - B or C - D, from rows A - D). This is done to safeguard against subjecting the display to twisting forces. Use a minimum of four mounting points. Good example ‡ ‡ Bad example × ‡ Use the following metal fixture to keep load from centering on the two mounting points at the top.
Special installation (Ceiling suspension (using wires)) Should the distance between the wall face and the unit be 300 mm or less, treat the clearance in the rear cover of the pop or that of the fixture nearer to the wall as the clearance A and apply the wall hanging conditions in 3.4.2. wall hanging. Metal fixture Metal fixture PDP A A or more Wall 29
Special installation (Installation with the screen downward) 3.4.5 Installation with the screen downward This display is designed to be installed with the screen downward, but certain uses can interfere with proper ventilation. Please observe the following conditions: 1 Use plate metal that keeps all single holes clear and has dimensions no larger than those given in the following table. 2 Leave adequate ventilation space between the display and the ceiling.
Special installation (Installation with the screen downward) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Ceiling embedding) 3.4.6 Ceiling embedding This display is designed to accommodate embedding in a ceiling. Note that the allowable range of outside-air temperature depends on the installation conditions. Please observe the following requirements: 1 If the unit must be embedded in the ceiling, you must not block the side slots of the unit. Avoid blocking the ventilating holes in the rear as much as possible. Never block the side slots.
Special installation (Ceiling embedding) (2) When there is open space behind the wall and the angle (shape) as shown in the figure can be maintained on the wall back: Y 30° 30° 30° MAX 20 mm X If the space above the ceiling is open at an angle of 30° or less, the X, Y space temperature can be set up to 35 °C, regardless of ceiling thickness. 30° Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts.
Special installation (Ceiling embedding) (3) When the back of the ceiling is in the closed space Exhaust fan (air flow rate 2 m3/ min or more) \ C Exhaust MAX. 20 mm (on both left and right) B Y X \ A A Intake port Flow of air from the air conditioner C A 70 mm or less (on both left and right) B Operating this display in confined spaces is not recommended.
Special installation (Ceiling embedding) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Installation on the floor) 3.4.7 Installation on the floor This display is designed to accommodate floor installation, but certain specific installations may interfere with adequate ventilation. Always observe the following conditions: 1 Use plate metal that keeps all single holes clear and has dimensions no larger than those given in the following table. 2 Leave adequate ventilation space between the display and the floor.
Special installation (Installation on the floor) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Installation under the floor) 3.4.8 Installation under the floor • If protective glass or similar material is used, the following installation conditions must be observed: Floor Protective glass surface C C 600 mm or more 600 mm or more Intake Exhaust G F B B C C E A Exhaust fan Exhaust port Tempered glass, etc.
Special installation (Installation under the floor) Conditions for embedding under the floor | Looking in the direction of the arrow (see the previous page) C. L. 600 mm or more a A + 50 mm or less a b 60 mm or less a=b The size of the intake port is the same as that of the exhaust port. For the exhaust port only, add a fan at the position indicated in the left figure (in the case of a single fan). Fan placement....Place a fan in an upper position. * The maximum air flow rate of the fan is 2.0 m3/min.
Special installation (Installation under the floor) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Installation under the floor) After installation, measure the temperatures in the area shown in the figure below to make sure that the values are within the specified range. m Intake side Room temperature + 5 °C or less m 10 m m 10 Exhaust side (temperature of the exhaust from FAN) Room temperate + 15 °C or less * Using our multi-installation fixture (PDM-4001) eliminates the need to set the temperature after installation.
Special installation (Installation under the floor (using the PDM-4001)) 3.4.9 Installation under the floor (using the PDM-4001) • If protective glass or similar material is used, the multi-installation fixture (PDM-4001) shown in the following figure is very useful. Floor Protective glass surface C C B 600 mm or more 600 mm or more Intake Exhaust B C C A Exhaust fan Exhaust port A + 50 mm or less 60 mm or less B Tempered glass, etc.
Special installation (Installation under the floor (using the PDM-4001)) Conditions for embedding under the floor: | Looking in the direction of the arrow (see the previous page) C. L. 600 mm or more a A + 50 mm or less a b 60 mm or less a=b The size of the intake port is the same as that of the exhaust port. For the exhaust port only, add a fan at the position indicated in the left figure (in the case of a single fan). Fan placement....Place a fan in an upper position.
Special installation (Wall hanging (vertically wall-hanging equipment)) 3.4.10 Wall hanging (vertically wall-hanging equipment) This display is designed to accommodate a range of wall installations. For this type of installation, carefully consider all installation specifics before beginning work, since these factors can significantly affect the temperature of the air surrounding the display.
Special installation (Wall hanging (vertically wall-hanging equipment)) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. The fixing method marked cannot be used for the unit. When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Wall embedding (vertically wall-embedding equipment)) 3.4.11 Wall embedding (vertically wall-embedding equipment) This display is designed to accommodate embedding in a wall. Since the allowable range of outside-air temperature depends on the installation conditions. Please observe the following conditions: 1 If the unit must be embedded in the wall, the side slots of the unit must not be blocked. Avoid blocking the ventilating holes in the rear as much as possible.
Special installation (Wall embedding (vertically wall-embedding equipment)) (2) When there is open space behind the wall and the angle (shape) as shown in the figure can be maintained on the wall back: 30° X 30° MAX. 20mm 30° Y Exhaust If the rear wall is tilted at 30° or less, the X, Y space temperature can be set up to 35 °C, regardless of the wall thickness. X 100 mm 100 mm Y MAX. 20 mm (both top and bottom) 30° Securing method: Basically, the unit is secured as indicated below.
Special installation (Wall embedding (vertically wall-embedding equipment)) (3) If the space behind the wall is enclosed: Exhaust fan (air flow rate: 2 m3/min or more) MAX. 20 mm (both left and light) X A C Exhaust B Y A \ A B X Y 100 mm Flow of air from air conditioner 100 mm 70 mm or less (both left and right) 48 A Intake hole C Operating this display in confined spaces is not recommended.
Special installation (Wall embedding (vertically wall-embedding equipment)) Securing method: Basically, the unit is secured as indicated below. Keep open all areas other than the shaded parts. cannot be used for the unit. The fixing method marked When the unit is fixed on a structure, select a structure of the proper thickness and height. Care must also be taken regarding the number of fixing bolts to be used (see “3.4.1 Fixing on a structure”).
Special installation (Horizontal connections) 3.4.12 Horizontal connections While the display is designed to accommodate side-by-side installations, keep in mind that specific installation configurations may affect ventilation. Observe the following requirements: 1 Installation of up to three units (Horizontal connection) The following table lists the operating temperature conditions. Use the units under conditions that keep the outside atmosphere in this range.
Special installation (Horizontal connections) 2 Installation of more than four units (Horizontal connection) Forced air-cooling is needed. To use four units, place partitions (heat resistant) between adjoining units, as illustrated below. Then, forcedly ventilate from under the units with the fans. If ventilation from under the units is impossible, always check the temperature at the back of the units and forcedly ventilate in the direction of the flowing air with a fan. In that case, do not use partitions.
Special installation (Horizontal connections) 3 PDK-4005 wall-mounted Horizontal connections (maximum of four units) A-unit B-unit W C-unit W D-unit W The following table provides recommended operating temperatures for side-by-side installations of the PDK-4005. Clearance W between the sets Ambient operating temperatures 400 mm ≤ W 0 to 35 °C 0 to 30 °C (Still) 20 ≤ W < 400 0 to 35 °C (Animation) Cannot be used.
Special installation (Horizontal connections) 53
Special installation (Vertical connections) 3.4.13 Vertical connections This machine is designed to be used vertical connection, but some operations under vertical connection may adversely affect ventilation in the machine. Therefore, observe the following conditions for safe operation: 1 Installation of up to three units (Vertical connection) The following table lists the operating temperature conditions. Use the units under conditions that keep the outside atmosphere in this range.
Special installation (Vertical connections) 2 Installation of more than four units (Vertical connections) This configuration is not recommended. If you do use this configuration, make sure you observe the following conditions. Ambient operating temperature Clearance A to the wall A ≥ 300 mm Use forced air-cooling until the intake and exhaust temperature values are within the specified range (see the following figure).
Functions and features of standard metal fixtures 4.1 Functions and features of standard metal fixtures Our plasma display (PDP-V401 ) features a large screen, high luminance, and high picture quality. In addition, the plasma display is so light and thin that it can be installed in a far wider area than competing displays now on the market.
Handling standard metal fixtures 4.2 Handling standard metal fixtures 4.2.1 Precautions on handling metal fixtures This chapter describes how to install and handle metal fixtures specially designed for plasma displays sold by us, PIONEER. We sell this unit on the premise that it will be installed by specialist vendors with sufficient technical skill. The plasma display must be installed by a specialist in this work or by the dealer from which you made your purchase. 4.2.
Mounting standard metal fixtures (Stand: an accessory to PDP-V401 ) 4.3 Stand (an accessory to PDP-V401 ) 4.3.1 Installing the stand 1. Attach the stand to the display using M8 commercial screws whose length equals the thickness of the table to which the fixture is attached plus 25 mm. 3. Insert the main body of the plasma display into the stand. 4. Fix the main body to the stand with the washers and bolts provided. Front 590 100 Rear 100 2.
Mounting standard metal fixtures (Stand: an accessory to PDP-V401 ) 4.3.2 Outer-dimensions diagram (Unit: mm) 250 100 70 66 49 65 11 22.4 24.2 11 65 1.5 59
Mounting standard metal fixtures (PDK-4001) 4.4 Tilting stand: PDK-4001 4.4.1 Specifications Outer dimensions ....... 916 (W) × 346.9 (D) × 761 (H) mm (When the plasma display is mounted vertically) Weight ......................... 5.5 kg (metal fixture alone) 36.3 kg <37.1 kg> (metal fixture with plasma display PDP-V401 ) Adjustable angle range .... Up to 20° from vertical Turning angle Turning force Material ........................ Steel pipe for general structures (STK-MR) Treatment .......
Mounting standard metal fixtures (PDK-4001) 4.4.2 Assembling and installing the metal fixture and mounting the plasma display 7 Procedure for assembling the fixture 1. Insert the round joint into each end of the joint pipe. 2. Temporarily attach one joint pipe to the stand frame L or R using an M8 × 60 hexagon socket button head screw and washer. 3. Temporarily attach the other stand frame to the other joint pipe.
Mounting standard metal fixtures (PDK-4001) Precautions for assembly ¶ First read the instruction manual. Observe the following points when attaching the stand frame to the plasma display. 1.Use 45-mm bolts (shorter bolts). 2.Before securing the display with the bolts, verify that the positions of the display nuts match the bolt hole positions in the stand frame. 3.
Mounting standard metal fixtures (PDK-4001) 63
Mounting standard metal fixtures (PDK-4002) 4.5 One-sided, ceiling-suspension metal fixture for the plasma display: PDK-4002 4.5.1 Specifications Outer dimensions .............. 916 (W) × 300 (D) × 1162 (H) mm (When the plasma display is mounted horizontally) Weight ................................ 12.6 kg (metal fixture alone) 43.4 kg <44.2 kg> (metal fixture with plasma display PDP-V401 ) Adjustable angle range ..... 25° down from horizontal, 45° to the left or right Material ..................
Mounting standard metal fixtures (PDK-4002) 4- φ 13.5 × 22 φ 240.5 300 325 φ 70 170 200 300 200 7 Outer-dimension diagram (Unit: mm) 805 1162 φ 60.5 14 25° 916 118 4 5° 45 256 51 102 ° Outline path of the plasma display when it is tilted 25° 22 69 Angle of rotation: 45° to the left or right R4 R5 Outline path of the plasma display when it is tilted 25° 65
Mounting standard metal fixtures (PDK-4002) 4.5.2 Assembling and installing the metal fixture and mounting the plasma display (same procedure as for the PDK-4003) 1) Preparation Assembling the PDK-4002 fixture requires the following tools. Prepare them before starting work. (The PDK-4003 is assembled using the same tools.
Mounting standard metal fixtures (PDK-4002) Pattern paper Ceiling flange COMP Flat washer [WC100FZK] Hexagonal socket head bolt (to eliminate backlash) (M6 × 10) [SME60H100FZK] Spring washer [WS100FZK] Hexagonal socket head bolt (M10 × 85) [SME100H850FZK] Flat washer [WC80FZK] Hexagonal socket head Cable holes bolt (for tilt adjustment) (M6 × 10) [SME60H100FZK] Support COMP Hexagonal socket head bolt (M8 × 75) [SME80H750FZK] Spring washer [WS80FZK] Spacer Hexagonal socket head bolt (to eliminate b
Mounting standard metal fixtures (PDK-4002) 3) Mounting the plasma display (For the PDK-4003, the same procedure is used to mount two displays.) 1. Remove the 6 hole rivets (arranged lengthwise) from the back of the plasma display with a coin or the like. 2. Mount the monitor mounting bolt assemblies (three each for the left and right) delivered with the display in the mounting holes on the back of the plasma display. 3.
Mounting standard metal fixtures (PDK-4002) 69
Mounting standard metal fixtures (PDK-4003) 4.6 Double-sided, ceiling-suspension metal fixture for the plasma display: PDK-4003 4.6.1 Specifications Outer dimensions .............. 916 (W) × 466 (D) × 1162 (H) mm (When the plasma display is mounted horizontally) Weight ................................ 16.5 kg (metal fixture alone) 78.1 kg <79.7 kg> (metal fixture with two plasma displays PDP-V401 ) Adjustable angle range ..... 25° down from horizontal, 45° to the left or right Material ..........
Mounting standard metal fixtures (PDK-4003) 4- φ 13.5 × 22 300 φ 240.5 170 φ 70 325 200 300 200 7 Outer-dimension diagram (Unit: mm) 14 25° 25° 1162 805 φ 60.5 916 233 233 (466) 45 R5 45 ° 371 ° 371 742 Outline path of the plasma display when it is tilted 25° 86 (R 58 6) Angle of rotation: 45° to the left or right Outline path of the plasma display when it is tilted 25° 45 ° 45 ° 4.6.
Mounting standard metal fixtures (PDK-4004) 4.7 Ceiling-suspension metal fixture for the plasma display (head screw type): PDK-4004 4.7.1 Specifications Outer dimensions .............. 916 (W) × 240 (D) × 792 (H) mm (When the plasma display is mounted horizontally) Weight ................................ 5.5 kg (metal fixture alone) 36.3 kg <37.1 kg> (metal fixture with plasma displays PDP-V401 ) Adjustable angle range ..... 25° down from horizontal Material ..............................
Mounting standard metal fixtures (PDK-4004) 4.7.2 Assembling and installing the metal fixture and mounting the plasma display 1) Preparation Assembling the metal fixture requires the following tools. Prepare all tools before starting work. • Wrench or spanner (side size: 12 mm) • Hexagonal wrench (side size: 6 mm for M8) In addition, the installation work requires a drill to machine the ceiling. Prepare a suitable drill.
Mounting standard metal fixtures (PDK-4004) 3) Mounting the plasma display 1. Remove the 6 hole rivets (arranged lengthwise) from the back of the plasma display. 2. Install the monitor mounting bolt assemblies (three each on the left and right) provided with the display in the mounting holes on the back of the plasma display. 3. Loosen only the top mounting screws for the left and right monitor brackets, and tilt the monitor brackets all the way (do not loosen the bottom screws). 4.
Mounting standard metal fixtures (PDK-4004) 75
Mounting standard metal fixtures (PDK-4005) 4.8 PDP bracket: PDK-4005 4.8.1 Specifications Outer dimensions .............. 916 (W) × 138 (D) × 714 (H) mm Weight ................................ 3.3 kg (metal fixture alone) 34.1 kg <34.9 kg> (metal fixture with two plasma displays PDP-V401 ) Material .............................. Steel pipe for general structures (STK-MR) Treatment ........................... Semi-matt black paint Package dimensions ..........
Mounting standard metal fixtures (PDK-4005) 4.8.2 Assembling and installing the metal fixture and mounting the plasma display 1) Outer-dimension diagram (Unit: mm) • PDP bracket weight: 3.3 kg • PDP bracket weight + display weight: 34.1 kg <34.9 kg> (when PDP-V401 is installed) 620 916 20 53 590 23 455 528 700 30 40 400 660 714 400 4- 9 137.8 77
Mounting standard metal fixtures (PDK-4005) 2) Assembly procedure 1. Temporarily tighten the vertical frame (1) and the horizontal frame (2) by using the M5 plus/minus screw (5) and the M5 wave washer (4). 1 4 3 2 3 4 5 1 4 4 5 5 4 2 5 3 3 4 When assembling the PDP bracket, install an M8 nut, as shown, to keep the Special eye bolt from loosening. (This step is not described in the instruction manual.) 3 7 Four M8 nuts * Secure the nut as close to the root of the bolt as possible. 1.
Mounting standard metal fixtures (PDK-4005) 2. Place the fixture on a horizontal table, tighten all bolts, and tighten the four bolts (3). 3. With the screen of the plasma display facing downward, place the display on the edge of a flat and stable table, as shown in the figure. Be sure not to drop or damage the display. PDP bracket 6 6 7 7 Table 4. Tighten the assembled PDP bracket at four points using M8 hexagonal socket button head screws (6) and M8 wave washers (7).
Mounting standard metal fixtures (PDK-4005) 4) Installation example During installation, strictly observe the related operating conditions in “3.4 Special installation”. 7 Wire hanging Attach wires to the bolts, as indicated in the figure. To attach the wires to the ceiling, secure two wires at two independent points for safety. Wire • To keep the plasma display main body from vibrating, fix the main body by attaching wire to the bottom bolt.
Mounting standard metal fixtures (PDK-4005) 7 Suspending connected plasma displays using wires More than one display can be connected, as shown in the figure. (Maximum: 3 displays) When wires are fixed to the ceiling, use two wires fixed at two independent points. Hole (9-mm dia.) Hole (9-mm dia.) Hole (9-mm dia.) Hole (9-mm dia.) Wire • To prevent plasma displays from tilting, fix them with wires that pass through the bottom bolts.
Mounting standard metal fixtures (PDK-4006) 4.9 Wall hanging metal fixture for the plasma display : PDK-4006 4.9.1 Specifications Outer dimensions .............. 912 (W) × 42 (D) × 589 (H) mm Weight ................................ 6.7 kg (metal fixture alone) 37.5 kg <38.3 kg> (metal fixture with two plasma displays PDP-V401 ) Material .............................. Steel pipe for general structures (STK-MR) Treatment ........................... Semi-matt black paint Package dimensions .........
Mounting standard metal fixtures (PDK-4006) 4.9.2 Assembling and installing the metal fixture and mounting the plasma display 1) Outer-dimension diagram (Unit: mm) Weight ................................. 6.7 kg (metal fixture alone) Weight ................................. 37.5 kg <38.3 kg> (metal fixture with plasma display PDP-V401 ) 20 (27) 42 11 20 37 50 (268.5) 860±1.0 355 455 555 655 500 589 35 3.2 8 – 9 (f 23) (124.8) 38 400 580 (597.
Mounting standard metal fixtures (PDK-4006) 2) Precautions before assembly • The vertical frame is for the left side and the right side. Mount the frame so that the hexagonal socket faces outward for both the left and right sides. • Set a lateral frame with the shorter socket diameter closer to the wall side. A total of 14 holes are involved in mounting the frame to the wall. 3) Assembly procedure 1. Loosen the screw in a and remove one end of the hook fixture.
Mounting standard metal fixtures (PDK-4006) 4) Mounting the monitor fixing bolt to the plasma display 104 860 590 4 104 250 49.8 1. Mount the monitor fixing bolt at four points on the rear of the plasma display. 4 49.8 250 660 4 4 101.5 48.8 14-M8 (with φ 16 hole rivet) Make the end of the nut 4 flush with the screw. 2. Mount the assembled metal fixture to the wall. Mount the assembled metal fixture to the wall, using screws or bolts, attaching at a minimum of four points (shown below as b).
Mounting standard metal fixtures (PDK-4006) 3. After securing the fixture with screws, open it as shown in the figure and tighten the screws c on the left and right sides of the vertical frame. Wall side c 5) Mounting the plasma display 1. As shown below, two workers should hold the left and right ends of the plasma display and insert four monitor fixing bolts into the mounting fixture holes. First insert the bolts in the bottom holes, then in the top holes.
Mounting standard metal fixtures (PDK-4006) 6) Setting the optimal angle This metal fixture is infinitely variable in a 25° range. This work requires two workers. 1. Loosen the left and right screws c of the vertical a frame. 2. Lowering the arm, press against the display to get the best angle. 3. When the desired angle is achieved, tighten the screws c on both sides. When the monitor is flat against the wall, use screws to connect the variable side and fixed side of the hook fixture shown above.
Mounting standard metal fixtures (PDK-4006) 7) Recommended ambient operating temperature (in the open state) 5° or more Wall Angle: less than 5° Operate at 0 to 35 °C. (Do not cover the metal fixture or the sides of the display main body.) 88 Wall Angle: 5° or more May be used between 0 to 40 °C. (Do not cover the metal fixture or the sides of the display main body.
Mounting standard metal fixtures (PDK-4006) 89
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 4.10 Infrared reduction filter: PDA-4001 Protective filter: PDA-4002 4.10.1 Specifications and features (Infrared reduction filter: PDA-4001) 1) Specifications Transmittance .................... Transmittance of light in the visible spectrum - 70% Outer dimensions .............. 908 (W) × 73.3 (D) × 908 (H) mm Weight ................................ 3.6 kg (filter only) 34.4 kg <35.
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 4.10.2 Specifications and features (Protective filter: PDA-4002) 1) Specifications Transmittance .................... Transmittance of light in the visible spectrum - 92% Outer dimensions .............. 908 (W) × 73.3 (D) × 908 (H) mm Weight ................................ 3.6 kg (Filter only) 34.4 kg <35.2 kg> (metal fixture with plasma display PDP-V401 < PDP-V401E>) Material .............................. Acrylic Packing dimensions ..........
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 4.10.3 Assembling and installing the metal fixture and mounting the plasma display 1) Outer-dimension diagram (Unit: mm) Filter weight ...............................................................3.6 kg 96.3 Filter weight + display weight ................................... 34.4 kg <35.2 kg> (when PDP-V401 is mounted) 908 (filter's outer dimensions) 92 73.3 104 718.
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 2) Mounting procedure 1. Remove the hole rivets (eight points) indicated by the arrows using a coin or the like. 3. The metal fixture installed (seen from the back of plasma display) 2, 3 2. Install two metal fixtures to the bottom of the plasma display using the hexagonal socket button bolt and washer, according to the outer shape of the fixture. 1 2, 3 1 4.
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 5. Assembling the filter Install the filter assembled in Step 4, hanging it on the metal fixture from the top of the plasma display. Set the bottom of the filter outside the metal fixture 7. With the filter installed (front) When all assembly work is complete, peel off the protective film on the front of the filter. and attach with the decorative screws. Always install from above the filter. 2 3 3 2 D 5 D 8.
Mounting standard metal fixtures (PDA-4001 • PDA-4002) 4.10.4 White balance When the infrared reduction filter (PDA-4001) is mounted on the display, the tone may change. In this case, we recommend that you adjust the white balance. 4.10.5 Mounting the PDP bracket (PDK-4005) with PDA-4001 and PDA-4002 mounted To attach the PDP bracket (PDK-4005) with the PDA-4001 and PDA-4002 mounted, tighten along with the filter-supporting metal fixture, as shown below.
Mounting standard metal fixtures (PDP-S01-LR) 4.11 Speaker system: PDP-S01-LR 4.11.1 Before operation • To get the best performance from this speaker system, first read the instruction manual. Keep the manual handy for easy future reference. • The speaker's nominal impedance is 8 Ω. Connect to a stereo amplifier capable of driving loads ranging from 4 to 16 Ω. • Observe the following precautions to protect the speaker from damage caused by high input. • Do not apply inputs higher than the recommended level.
Mounting standard metal fixtures (PDP-S01-LR) 4.11.3 Assembling and installing the metal fixture and mounting the plasma display 1) Outer dimension diagram (Unit: mm) Speaker weight ................................................................................ 2.9 × 2 = 5.8 kg Plasma display (PDP-V401 ) + speaker weight ........... 36.6 kg <37.4kg> 88 103.2 1070 3 74 714 916 97
Mounting standard metal fixtures (PDP-S01-LR) 2) Mounting the metal fixture The metal fixture is installed by one of two methods, which are outlined below: (1) When mounting the metal fixture to the side of the display: • The figure illustrates mounting the speaker to the right side of the display. “PDP-S01” Plasma display UP 1. Remove the 2 hole rivets (from the bottom) at the back of the display. (Use a coin to turn the hole rivets.) 2.
Mounting standard metal fixtures (PDP-S01-LR) (3) Connecting to the stereo amplifier 1. Turn off power to the stereo amplifier. 2. Use the supplied speaker cables to connect the input terminal of the speaker system to the speaker output terminal of the stereo amplifier. The polarity of the input terminal is plus (+) for red (terminal to the right of the following figure) and negative (–) for black (terminal to the left of the following figure).
Mounting standard metal fixtures (Precautions for installing the optional speaker) 4.11.4 Precautions for mounting different metal fixtures after the optional speakers are attached to the plasma display main body When different metal fixtures are mounted after the optional speakers are mounted to the plasma display, the following steps and precautions must be observed, depending on the specific type.
Mounting standard metal fixtures (Precautions for installing the optional speaker) 101
Mounting standard metal fixtures (Precautions for installing the optional speaker) 2) Ceiling-suspension metal fixture for plasma display (PDK-4002 / PDK-4003 / PDK-4004) Monitor-mounting bolt (supplied with the ceiling suspension metal fixture for plasma display) Monitor-mounting bolt (supplied with the ceiling suspension metal fixture for plasma display) Hole rivet Fig.
Mounting standard metal fixtures (Precautions for installing the optional speaker) Monitor mounting bolt (supplied with the ceiling suspension metal fixture for the plasma display) Washer of φ 25-mm outer diameter (supplied with optional speaker) Ceiling-suspension metal fixture for plasma display Fig. 3 This shows the PDK-4002. The same illustration applies to the PDK-4003 and PDK-4004.
Mounting standard metal fixtures (Precautions for installing the optional speaker) 3) Wall-hanging metal fixture (PDK-4006) Washer of φ 15-mm outer diameter (supplied with the optional speaker) Hexagonal socket head button bolt (supplied with the optional speaker) Monitor mounting bolt (supplied with the PDK-4006) Hole rivet Fig.
Mounting standard metal fixtures (Precautions for installing the optional speaker) Washer of φ 25-mm outer diameter (supplied with the optional speaker) Monitor fixing bolt (supplied with the PDK-4006) Wall hanging metal fixture Monitor fixing bolt (supplied with the PDK-4006) Fig. 5 105
Before making adjustments 5.1 Before making adjustments This machine can be adjusted by three methods: • Operation panel of the plasma display main body • Remote control • PC (RS232C control) Before starting adjustments, make sure you have thoroughly read and understood this section. 5.1.1 Operation mode This machine may be used in four operational modes. Mode transition is described on page 111. 1) Normal operations mode This mode reproduces images, with power turned on.
Before making adjustments 3) Integrator mode This mode offers an adjustment function for the integrator. This mode consists of various menu mode items and additional settings for white-balance adjustment and various modes. This mode may be entered only when powering on, within 3 seconds after the menu button is pressed. When you enter Integrator mode, all data adjusted in Menu mode automatically returns to reset values (center values), except for CLK. PHS.
Before making adjustments STANDBY state STANDBY/ON MENU MENU Normal Operations mode + STANDBY/ON MENU Integrator mode Menu mode PICTURE PARAMETER RS232C Adjustment mode PICTURE PARAMETER CONTRAST BRIGHT. COLOR (Note:1) TINT (Note:1,4) SHARPNESS (Note:1) CLK.FRQ. (Note:2) CLK.PHS. (Note:2) HOR.POS. (Note:2) VER.POS. (Note:2) INIT. CONTRAST BRIGHT. COLOR (Note:1) TINT (Note:1,4) SHARPNESS (Note:1) CLK.FRQ. (Note:2) CLK.PHS. (Note:2) HOR.POS. (Note:2) VER.POS.
Before making adjustments (1) List of user-mode adjustable items/variable range/variable amount for each input Variable range 1 STEP Variable amount CONTRAST –96 to +96 ×3 BRIGHT –96 to +96 ×3 COLOR –96 to +96 ×3 TINT –96 to +96 ×3 SHARPNESS –96 to +96 ×3 CLK. FRQ. –32 to +32 ×1 CLK. PHS. –128 to +127 ×1 HOR. POS. –32 to +32 ×1 VER. POS.
Before making adjustments 5.1.2 Picture quality and white-balance adjustment memory This machine contains the following 28 memory areas. Note that there are only 20 adjustable areas, since the FACTORY area is read-only.
Before making adjustments 5.1.3 Phase-adjustment memory This machine contains the following 10 memory areas. Of these, note that only 8 are adjustable, since the FACTORY area is read-only. RGB1(BNC terminal input) NTSC PAL VGA mode PC9800®normal mode Macintosh®13-inch mode FACTORY RGB2(Mini D-SUB terminal input) NTSC PAL VGA mode PC9800®normal mode Macintosh®13-inch mode NOTE) is for PDP-V401E only FACTORY • VGA mode 640 dots × 480 lines/horizontal-scanning frequency 31.
Before making adjustments 5.1.5 Last memory On this machine, the items below are saved as the latest data in the memory, except when the following is performed without satisfying memory timing requirements: • • Turning off main power Removing the power cord from the plug socket • Turning off the plug socket breaker Note: command by RS232C (Inhibit command for the OSD display) is not saved as the latest data in the memory. No. ITEM MEMORY TIMING 1 STANDBY/ON Approx.
Before making adjustments MEMORY TIMING No. ITEM 5 HOUR METER counting No. At any time, and when STANDBY status is activated 6 KEY LOCK/UNLOCK Approx. 4 seconds after operation ® 7 Mask color when PC-9800 is used Approx. 4 seconds after operation 8 Setting of mask when NTSC is used Approx. 4 seconds after operation 9 MP mode Approx. 4 seconds after operation 10 CONTRAST adjustment data 11 BRIGHT.
Performing adjustments on the plasma display operation panel and remote control 5.2 Performing adjustments on the plasma display operation panel and remote control 5.2.1 Menu mode 1) When input is RGB1 (BNC) or RGB2 (Mini D-SUB) STANDBY /ON For RGB1 (BNC), RGB2 (Mini D-SUB), Video, or Y/C inputs, make the proper adjustments for each input. INPUT MENU ADJUST SET VID EO IN SE PUT LEC T ME STA ND BY /ON RG B1 Y/C RG B2 NU SE T Move to the Menu screen using the MENU button.
Performing adjustments on the plasma display operation panel and remote control Adjust each item in the following way: CONTRAST ....... Adjust CONTRAST to improve visibility for ambient brightness. BRIGHT ............. Adjust BRIGHT to vary screen brightness. CLK.FQR. .......... This function is used to make adjustments when characters are (–32 to +32) indistinct against the background, or rainbow-like noise occurs. (The function works by adjusting the internal clock frequency.) CLK.PHS. ...........
Performing adjustments on the plasma display operation panel and remote control 2) For VIDEO and Y/C input STANDBY /ON INPUT MENU ADJUST SET VID EO IN SE PUT LEC T ME NU STA ND BY /ON RG B1 Y/C RG B2 SE T Move to the Menu screen using the MENU button. Remote control Plasma display main body P I CTURE PARAMETER CONTRAST BR I GHT. COLOR T I NT SHARPNESS I N I T. MENU MENU SET : SEL. MENU : EX I T Currently-selected items are indicated in burgundy. Select an item to adjust.
Performing adjustments on the plasma display operation panel and remote control Adjust each item in the following way: CONTRAST ....... Adjust CONTRAST to improve visibility for ambient brightness. BRIGHT ............. Adjust BRIGHT to improve display of dark images (such as a night scene or dark hair. COLOR .............. Adjust color to desired intensity (set color to lighter levels for natural display). TINT ................... Adjust the function to improve tint. SHARPNESS .....
Performing adjustments on the plasma display operation panel and remote control 5.2.2 Integrator mode 1) Integrator mode main menu (for VIDEO and Y/C input) P A R A M E T E R P I C T U R E C O N T R A S T 1 2 8 1 2 8 B R I G H T . C O L O R 1 2 8 1 2 8 * T I N T S H A R P N E S S 1 2 8 I N I T . W H I T E B A L A N C E A D D I T I O N A L S E T I N I T I A L T O T A L U P * Adjustments cannot be carried out for PDP-V401E if PAL signals are input. Adjustment items will also not be displayed.
Performing adjustments on the plasma display operation panel and remote control 3) Quality and phase adjustment mode P I C T U R E P A R A M E T E R C O N T R A S T 1 2 8 Using the remote control, make adjustments with the 2 and 3 buttons. Using the operation panel, make adjustments with using the +, – buttons. The range of possible adjustments is 000 - 255. Values set in this mode become the central values to be adjusted in Menu mode. The following parameters can be adjusted in this item.
Performing adjustments on the plasma display operation panel and remote control 5) White-balance adjustment menu selection mode P A R A M E T E R P I C T U R E W H I T E B A L A N C E 1 2 8 1 2 8 R H I G H G B R H I G H H I G H L O W 1 2 8 1 2 8 G L O W 1 2 8 B L O W I N I T . 1 2 8 A D D I T I O N A L S E T U P I N I T I A L I Z E T O T A L Using the remote control, select the desired item with the 5 and ∞ buttons, and enter that choice with the SET button.
Performing adjustments on the plasma display operation panel and remote control 7) Integrator white-balance adjustment mode (adjustment reset) P A R A M E T E R P I C T U R E W H I T E B A L A N C E I N I T I A L I Z E ? Y E S N O A D D I T I O N A L S E T U P I N I T I A L I Z E T O T A L This function returns adjusted values, and are set in adjustment mode to the factory-preset values, which are within the range of values currently held in the selected memory area.
Performing adjustments on the plasma display operation panel and remote control 9) Mode setting menu mode (PC98, VGA, or MAC is input) P A R A M E T E R P I C T U R E W H I T E B A L A N C E A D D I T I O N A L S E T U P M O D E C O L O R R A T E B A U D M E T E R H O U R 1 4 8 0 0 B P S M P O F F M O D E T O T A L 1 2 3 4 5 I N I T I A L I Z E Operation is the same as with other input functions.
Performing adjustments on the plasma display operation panel and remote control 11) Baud-rate setting mode B A U D R A T E 1 2 0 0 2 4 0 0 B P S B P S 4 8 0 0 B P S 9 6 0 0 1 9 2 0 0 B P S B P S Operation is the same as with other input functions. With the remote control, use the 5 and ∞ buttons to select the item to be set, and confirm your selection with the SET button. With the operation panel, select the item with the + and – buttons, then confirm your selection with the SET button.
Performing adjustments on the plasma display operation panel and remote control 13) MP (Motion Picture) mode-setting mode M P M O D E O N O F F This function is valid only for PC98, VGA, and MAC input signals (and for NTSC inputs double-rate-converted from RGB1 and RGB-2 terminals). With the remote control, use the 5 and ∞ buttons to select the item to be set, and confirm your selection with the SET button.
Performing adjustments on the plasma display operation panel and remote control 14) Initial reset setting mode (total adjustment) P A R A M E T E R P I C T U R E W H I T E B A L A N C E A D D I T I O N A L S E T U P I N I T I A L I Z E T O T A L I N I T I A L I Z E ? Y E S N O This function restores adjusted values for PICTURE PARAMETER and WHITE BALANCE to factory-preset values, which are within the range of values currently held in the selected memory area.
Outer control by RS232C 5.3 Outer control by RS232C The main body is equipped with an RS232C port to allow different operations using an external PC, including adjustment of picture quality, white-balance, and phase. 5.3.1 Precautions • The contents of adjustment are placed in last-memory with the command. Once adjustments are complete, perform . The display for screen adjustment disappears. • Some RS232C commands can be used in normal mode (during normal operation). Refer to “5.3.
Outer control by RS232C 5.3.2 Interface 1) Connector D-sub 9 pin 2) Pin assignment PIN NO. 2 Symbol TXD Signal NAME Transmitted Data 3 8 RXD CTS Recieved Data Clear To Send 5 GND Signal Ground 3) Baud rate 4800 bps (possible settings include 1200, 2400, 9600, and 19200 bps) Notes: Set this value so that the machine's baud rate equals the PC baud rate.
Outer control by RS232C 5.3.3 RS232C commands table Explanation of the tables • Normal validity Commands that may be used even when not in RS232C adjustment mode (after sending commands) • Number direct Commands sent directly followed by numbers 000-255, which immediately become the new adjusted values. • UP/DOWN command Commands followed by UPn/DWn (n is any number from 0 to 9) are capable of incrementing adjustment values up or down in increments of their values.
Outer control by RS232C Command name Name Validity in Validity of Validity of numberUP/ normal DOWN direct mode command command Function H HPS HMD H POSITION HOUR METER DISP. × × ‡ × ‡ × Adjusts horizontal phase. Displays hour meter. I IN1 IN2 IN3 IN4 INPUT1 INPUT2 INPUT3 INPUT4 ‡ ‡ ‡ ‡ × × × × × × × × Selects VIDEO input. Selects Y/C input. Selects RGB 1 input (BNC terminal). Selects RGB 2 input (miniD-SUB terminal).
Outer control by RS232C 5.3.4 List of GET commands What are GET commands? • Commands to output adjustment data from the PC connected to the plasma display to another personal computer • Adjustment data is output for each input function, each input mode, and each mode. • Adjustment data is output in ASCII. Note: Data in < > indicates a command name. 1) (GET POSITION DATA) — Phase-adjustment data is output in the following format: (1) STX (02H) (2) Adjustment data for /CLOCK FREQ (3BYTE).
Outer control by RS232C 4) GS2 (GET STATUS 2) - The status of each setting is output in the following format: (1) STX (02H) (2) MP mode setting status Example: MPY: Indicates MP mode ON. (3 BYTE): Output by command name. (3) NTSC Top/Bottom mask-mode setting status Example: NMG: Indicates Gray Mask On. (3 BYTE): Output by command name. (4) PC98 mask-mode setting status Example: MKB: Indicates mask setting of black. (3 BYTE): Output by command name. (5) ETX (03H) 131
KEY LOCK/UNLOCK 6.1 KEY LOCK/UNLOCK 6.1.1 Functions To prevent tampering following installation, invoke “KEY LOCK” status to prevent use of “the main-body operation panel” or “the remote control”. (RS232C commands are valid.) If an attempt is made to use “the operation panel” or “the remote control”, the screen displays “KEY LOCK” at the top right. The system is factory-set to “KEY UNLOCK” to enable use of “the operation panel” and “the remote control”. 6.1.
Mask color select/off when NTSC is input 6.2 Mask color select/off when NTSC is input 6.2.1 Functions This function selects black or gray mask (MASK GRAY/BLACK) processing for approximately 10 lines at the top or bottom of the screen, or reproduction of images (MASK OFF) for the whole screen (480 lines). This function is factory-set to MASK ON (black) state. + Mask NTSC MASK Mask approximately 10 lines at both top and bottom (black or gray).
Mask color select when PC-9800® is input / Pseudo contour 6.3 Mask color select when PC-9800® is input 6.3.1 Functions This function selects the color of the mask section at the top and bottom of the screen when PC-9800 is input with input function of RGB 1 or RGB 2. Black or gray Images are displayed over 400 lines. The display is factory-set to black. 6.3.2 Setting method This function can be set only through RS232C commands.
Precautions 6.5 Precautions • When the power to the display repeats turning off, some circuits mey be faulty (because of defective parts, etc.). Turn off the power to the plasma display and turn on the switch again after several seconds. When the power is turned off again, the system may be faulty. When it normally works, the system can be used without problems. • When the same images (such as stills and telop) are on the display for hours, images are printed on the display and not disappear.
Maintenance • Remove the plug from the plug socket before maintenance. • Maintenance of the cabinet/remote controller Do not use solvent such as benzene and thinner. The cabinet and remote controller may deteriorate in quality or the paint may peel off. Use a soft cloth to wipe off dust lightly. When they are very dirty, put a soft cloth in detergent diluted with water, fully wring it and wipe with it. Finish cleaning with a dry soft cloth.