INSTALLATION INSTRUCTION / OPERATION MANUAL MODEL KB-0333K Followed by indicating color: K = black, W = white, S = stainless steel FORCUSTOMER ASSISTANCE .................................... 2 CONNECT WIRING................................................. 8 CONSUMER LIMITEDWARRANTY............................... 3 INSTALL HOOD..................................................... 9 PRODUCT INFORMATION CARD.................................. 3 NON-DUCTED FILTERS................................
FOR CUSTOMER ASSISTANCE To aid in reporting this range hood, please record below the model number and serial number located on the unit. We also suggest you record all the information listed and retain for future reference.
CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.
IMPORTANTSAFETYINSTRUCTIONS READ ALL INSTRUCTIONS FORDOMESTICCOOKINGONLY TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact Sharp at the address or telephone number listed on page 2 of this manual. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
PREPARE I Determine whether hood will discharge vertically (3 1/4" x 10" or 7" round), horizontally (3 1/4" x 10" only) or be non-ducted. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minilnUln nulnber of transitions and elbows.
PREPARE THE 1 Remove 7" Round Duct Plate from top of hood. Set duct HOOD NON-DUCTED 7" ROUND DUCTPLATE INSTALLATION - Skip to page 8. The following Steps (6 thru INSTALLATION ONLY. plate aside - with mounting screws. 14) are for DUCTED (3) #8 SCREWS 6Remove Light Panel - held in LIGHT PANEL place with (5) #8 screws. Disconnect light wire assembly harness (white connector). 2Remove tape holding Filters in place. Pull down on filter tabs or finger holes and lift filters out. Set filters aside.
PREPARE 10 Re-install air chute and screw, re-connect wire harness and replace light panel. Note: Be careful not to trap wires between Support Fin and light panel. 11 Remove appropriate Duct Knockout(s) of hood. from top or back SEMI-CIRCULAR DUCT KNOCKOUT tRemove for 7" round discharge) REAR RECTANGULAR DUCT KNOCKOUT (Remove for 3W' x 10" horizontal discharge) 12 Horizontal Discharge Only: Remove the Plate in front of the horizontal discharge knockout. Cut the ties, lift plate out, and discard plate.
PREPARE THE HOOD Non-Ducted Installations Only: Requires a Performance Ring to be attached to the blower wheel. The Performance Ring is packed behind the Teflon :_Coated Bottom Cover. 5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely. Note: For information on non-ducted filters, see page 9. To install ring: 1, Remove Retaining Ring using a flat blade screwdriver. Set aside for later.
INSTALL I Hang hood from (4) mounting screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) keyholes. Tighten mounting screws securely. A long screwdriver works best. HOOD 4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately. PAR20, 50W MAX. HALOGEN BULB (2) - orR16, 40W MAX.
OPERATING mnsight 3 1 2 4 HEAT SENSOR 1 FAN There are four fan speeds from low (1) to high (4). Push any button to select one of the four fan speeds. Press another button to change fan speed. Push the same button to turn the fan off. A light above each fan button indicates the fan speed. Your Sharp Insight Range Hood is equipped with an advanced Heat Sensor. The Sensor monitors the temperature and automatically adjusts the fan to the appropriate setting.
CLEANING To clean hood: Remove filters. Use a damp cloth and a mild detergent to wipe all grease-laden surfaces. Do not use abrasive cloth, steel wool pads or scouring powder on the Teflon
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, SHARPELECTRONICS CORPORATION• Sharp Plaza, Mahwah, New Jersey 07430-2135 Inc.
INSTALLATION INSTRUCTION / OPERATION MANUAL MODEL KB-0333K Followed by indicating color: K = black, W = white, S = stainless steel FORCUSTOMER ASSISTANCE .................................... 2 CONNECT WIRING................................................. 8 CONSUMER LIMITEDWARRANTY............................... 3 INSTALL HOOD..................................................... 9 PRODUCT INFORMATION CARD.................................. 3 NON-DUCTED FILTERS................................
FOR CUSTOMER ASSISTANCE To aid in reporting this range hood, please record below the model number and serial number located on the unit. We also suggest you record all the information listed and retain for future reference.
CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.
IMPORTANTSAFETYINSTRUCTIONS READ ALL INSTRUCTIONS FORDOMESTICCOOKINGONLY TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact Sharp at the address or telephone number listed on page 2 of this manual. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
PREPARE I Determine whether hood will discharge vertically (3 1/4" x 10" or 7" round), horizontally (3 1/4" x 10" only) or be non-ducted. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minilnUln nulnber of transitions and elbows.
PREPARE THE 1 Remove 7" Round Duct Plate from top of hood. Set duct HOOD NON-DUCTED 7" ROUND DUCTPLATE INSTALLATION - Skip to page 8. The following Steps (6 thru INSTALLATION ONLY. plate aside - with mounting screws. 14) are for DUCTED (3) #8 SCREWS 6Remove Light Panel - held in LIGHT PANEL place with (5) #8 screws. Disconnect light wire assembly harness (white connector). 2Remove tape holding Filters in place. Pull down on filter tabs or finger holes and lift filters out. Set filters aside.
PREPARE 10 Re-install air chute and screw, re-connect wire harness and replace light panel. Note: Be careful not to trap wires between Support Fin and light panel. 11 Remove appropriate Duct Knockout(s) of hood. from top or back SEMI-CIRCULAR DUCT KNOCKOUT tRemove for 7" round discharge) REAR RECTANGULAR DUCT KNOCKOUT (Remove for 3W' x 10" horizontal discharge) 12 Horizontal Discharge Only: Remove the Plate in front of the horizontal discharge knockout. Cut the ties, lift plate out, and discard plate.
PREPARE THE HOOD Non-Ducted Installations Only: Requires a Performance Ring to be attached to the blower wheel. The Performance Ring is packed behind the Teflon :_Coated Bottom Cover. 5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely. Note: For information on non-ducted filters, see page 9. To install ring: 1, Remove Retaining Ring using a flat blade screwdriver. Set aside for later.
INSTALL I Hang hood from (4) mounting screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) keyholes. Tighten mounting screws securely. A long screwdriver works best. HOOD 4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately. PAR20, 50W MAX. HALOGEN BULB (2) - orR16, 40W MAX.
OPERATING mnsight 3 1 2 4 HEAT SENSOR 1 FAN There are four fan speeds from low (1) to high (4). Push any button to select one of the four fan speeds. Press another button to change fan speed. Push the same button to turn the fan off. A light above each fan button indicates the fan speed. Your Sharp Insight Range Hood is equipped with an advanced Heat Sensor. The Sensor monitors the temperature and automatically adjusts the fan to the appropriate setting.
CLEANING To clean hood: Remove filters. Use a damp cloth and a mild detergent to wipe all grease-laden surfaces. Do not use abrasive cloth, steel wool pads or scouring powder on the Teflon
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, SHARPELECTRONICS CORPORATION• Sharp Plaza, Mahwah, New Jersey 07430-2135 Inc.
INSTALLATION INSTRUCTION / OPERATION MANUAL MODEL KB-0333K Followed by indicating color: K = black, W = white, S = stainless steel FORCUSTOMER ASSISTANCE .................................... 2 CONNECT WIRING................................................. 8 CONSUMER LIMITEDWARRANTY............................... 3 INSTALL HOOD..................................................... 9 PRODUCT INFORMATION CARD.................................. 3 NON-DUCTED FILTERS................................
FOR CUSTOMER ASSISTANCE To aid in reporting this range hood, please record below the model number and serial number located on the unit. We also suggest you record all the information listed and retain for future reference.
CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product (the "Product"), when shipped in its original container, will be free from defective workmanship and materials, and agrees that it will, at its option, either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period(s) set forth below.
IMPORTANTSAFETYINSTRUCTIONS READ ALL INSTRUCTIONS FORDOMESTICCOOKINGONLY TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact Sharp at the address or telephone number listed on page 2 of this manual. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
PREPARE I Determine whether hood will discharge vertically (3 1/4" x 10" or 7" round), horizontally (3 1/4" x 10" only) or be non-ducted. For vertical or horizontal discharge, run ductwork between the hood location and a roof cap or wall cap. For best results, use a minilnUln nulnber of transitions and elbows.
PREPARE THE 1 Remove 7" Round Duct Plate from top of hood. Set duct HOOD NON-DUCTED 7" ROUND DUCTPLATE INSTALLATION - Skip to page 8. The following Steps (6 thru INSTALLATION ONLY. plate aside - with mounting screws. 14) are for DUCTED (3) #8 SCREWS 6Remove Light Panel - held in LIGHT PANEL place with (5) #8 screws. Disconnect light wire assembly harness (white connector). 2Remove tape holding Filters in place. Pull down on filter tabs or finger holes and lift filters out. Set filters aside.
PREPARE 10 Re-install air chute and screw, re-connect wire harness and replace light panel. Note: Be careful not to trap wires between Support Fin and light panel. 11 Remove appropriate Duct Knockout(s) of hood. from top or back SEMI-CIRCULAR DUCT KNOCKOUT tRemove for 7" round discharge) REAR RECTANGULAR DUCT KNOCKOUT (Remove for 3W' x 10" horizontal discharge) 12 Horizontal Discharge Only: Remove the Plate in front of the horizontal discharge knockout. Cut the ties, lift plate out, and discard plate.
PREPARE THE HOOD Non-Ducted Installations Only: Requires a Performance Ring to be attached to the blower wheel. The Performance Ring is packed behind the Teflon :_Coated Bottom Cover. 5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely. Note: For information on non-ducted filters, see page 9. To install ring: 1, Remove Retaining Ring using a flat blade screwdriver. Set aside for later.
INSTALL I Hang hood from (4) mounting screws. Slide hood towards wall until mounting screws are engaged in narrow end of (4) keyholes. Tighten mounting screws securely. A long screwdriver works best. HOOD 4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16, 40 W Maximum Incandescent Bulbs. Purchase bulbs separately. PAR20, 50W MAX. HALOGEN BULB (2) - orR16, 40W MAX.
OPERATING mnsight 3 1 2 4 HEAT SENSOR 1 FAN There are four fan speeds from low (1) to high (4). Push any button to select one of the four fan speeds. Press another button to change fan speed. Push the same button to turn the fan off. A light above each fan button indicates the fan speed. Your Sharp Insight Range Hood is equipped with an advanced Heat Sensor. The Sensor monitors the temperature and automatically adjusts the fan to the appropriate setting.
CLEANING To clean hood: Remove filters. Use a damp cloth and a mild detergent to wipe all grease-laden surfaces. Do not use abrasive cloth, steel wool pads or scouring powder on the Teflon
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, SHARPELECTRONICS CORPORATION• Sharp Plaza, Mahwah, New Jersey 07430-2135 Inc.