Absolute Maximum Ratings
Recommended Operating Conditions
Outline Dimensions
(Unit : mm)
General Purpose Distance
Measuring Sensor
Features
1. Less influence on the color and reflectivity of reflective
objects, due to optical triangle mesuring method
2. Distance judgement type
Judgement distance:15cm (Detection range:3 to 30cm)
3. External control circuit is unnecessary
Output can be directly connected to microcomputers
4. Low cost
*1 Open collector output
Parameter Symbol Rating Unit
Supply voltage V
CC V
Operating temperature T
opr 10 to +60 °C
0.3 to V
CC +0.3 V
0.3 to +7
Output terminal voltage
V
O
*1
Storage temperature Tstg 40 to +70 °C
(Ta=25°C)
Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
Parameter Symbol Rating Unit
V
CC 4.5 to 5.5 V
Operating Supply voltage
1.
Detection of objects such as home appliances and OA equipment,
detection of human body
Applications
R3.75
R3.75
3.75
10.1
14.75
16.34.157.5
φ3.2 hole
φ3.2 hole
6.3
2
8.4
7.2
13
2-1.5
13.5
18.9
+0.5
0.3
37
29.5
20±0.1
4.5
Light detector side
PWB
Lens case
1.2
3.3
Connector
Made by
J.S.T. MFG,
CO., LTD.
S3B-PH
Light emitter side
1
1 3
2
3
V
O
GND
V
CC
The dimensions marked
are
described the dimensions of
lens center position.
Unspecified tolerance : ±0.3mm
Terminal connection