R AIR PURIFIER OPERATION MANUAL Free Standing *Plasmacluster is a trademark of Sharp Corporation.
ENGLISH Plasmacluster Ion Control The unit controls the ratio of negative ions and positive ions depending on the condition of the room. • Clean Mode Approximately the same numbers of positive and negative ions are discharged. This mode is effective for reducing some airborne mold. • Ion Control Mode Plenty of negative ions exist in natural surroundings such as waterfalls or forests.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the air purifier. • Use only a 220 volt outlet. • Do not use the air purifier if the power cord or plug is damaged or the connection to the wall outlet is loosen. • Periodically remove dust from the power plug.
• During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipment. • Leave at least 60cm of space from the wall. The motor may overheat, causing a malfunction. • Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. • Avoid locations where curtains, etc., come into contact with the intake or air outlet.
PART NAMES MAIN UNIT DISPLAY Remote Control Receiver Filter Indicator Light SENTINEL Operation Indicator Light CLEAN-SIGN Light AUTO Operation Indicator Light 15min. HIGH operation Indicator Light Pollen Mode Indicator Light Fan Speed Indicator Lights OFF Timer Display Indicator Lights Sensor Sensitivity Select Switch Sensor sensitivity can be adjusted to “Normal” or “SENSITIVE” by this switch.
PREPARATION INSERTING BATTERIES IN THE REMOTE CONTROL the back cover 1 Remove Press and slide the back cover to remove. batteries 2 Insert Insert batteries with and as 3 Close the back cover Battery Information • The battery life is about 1 year. • The batteries for this remote control are for initial use only . Change the batteries when necessary. • Incorrect usage of the batteries may cause battery fluid leakage and/or damage.
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit within the plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 1 Remove the filters 1 Remove Panel. the Front Panel Front Pull the bottom of the Front Panel. 2 1 1 2 1 Hook out the Filter Frame and remove the Pre-Filter, 2 Pull Active Carbon Filter and HEPA Filter.
outlet. 2 Tabs Install the filters the HEPA Filter 1 Place within the Filter Frame with HEPA Filter the tabs facing up. Do not install the filter backwards or the unit will not operate properly. with the bands (2 places) facing up. ENGLISH the Active Carbon Filter 2 Place on top of the HEPA Filter Filter Frame Band Active Carbon Filter HEPA Filter Filter Frame the Pre-filter through 3 Place the bands (2 places) located Tabs (4 places) Band at the corners of the Active Carbon Filter.
OPERATION Main Unit Controls MAIN UNIT OPERATION Filter Indicator Light • • • • • • AUTO 15 min. HIGH POLLEN SILENT NORMAL MAX SENTINEL Operation Indicator Light Clean-Sign Light Plasmacluster Indicator Light MODE Button Power ON/OFF Button 2 1 Plasmacluster 1 Power ON/OFF Button • Used to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
SENTINEL Operation Indicator Light PLASMACLUSTER INDICATOR LIGHT Plasmacluster ion operation is selected using the remote control. Blue light When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmacluster Ion Mode and the air in the room is impure, this light will be activated and the unit will operate in Clean Mode.
OPERATION REMOTE CONTROL OPERATION POWER ON/OFF Button • When you press the POWER ON/OFF Button, a short beep will sound and operation will start in AUTO Mode. • Unless unplug the power cord, the operation starts from the previous mode the unit was operated in. • To stop, press the POWER ON/OFF Button again. A long beep will sound and operation will stop. Transmitter Filter Reset Button When the Washable Active Carbon Filter is cleaned and reinserted into the main unit, press the Filter Reset Button.
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sensors and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. MAIN UNIT To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
CARE AND MAINTENANCE WASHABLE ACTIVE CARBON FILTER CARE HAND WASH ONLY! DO NOT TUMBLE DRY! Care Cycle When the Filter Indicator Light lights up, this indicates that the filter needs to be cleaned. If the unit is kept on 24 hours a day then the Filter Indicator Light will be activated in about 2 months. The Filter Indicator Light is for reference. Clean the filter as often as necessary when odour persists. 1 Remove visible dirt with a vacuum cleaner.
FILTER REPLACEMENT GUIDELINES Depending on the usage environment, air outlet odour may become strong after several months. If dust or odours cannot be removed easily, replace the filters. (Refer to HOW SHARP AIR PURIFIER WORKS E-3) Guide for filter replacement timing • HEPA Filter • Active Carbon Filter About 5 years after opening About 5 years after opening REPLACING THE FILTERS 1 2 See page E-6,7 for directions on how to install the filters when replacing.
TROUBLESHOOTING Before calling for repair, please review the list below, since the problem may not be a unit malfunction. SYMPTOM REMEDY (not a malfunction) The Remote Control does not work • Have the batteries been depleted? • Are the batteries inserted correctly? • Is a fluorescent lighting in the room flickering due to service life? Odours and smoke are not removed • Clean or Replace the filters if they appear to be heavily soiled.
SPECIFICATIONS Fan Speed Operation Model Power supply Fan speed level Rated power Air Flow Volume Applicable floor surface Cord Length Dimensions Weight FU-P60S MAX 65 W 360 m3/hour 220V 50Hz NORMAL 9.6 W 138 m3/hour SILENT 4.0 W 36 m3/hour ~46m2* 2.5m 415mm(W)x241mm(D)x572mm(H) 8.5kg Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.7W of standby power.
FU-P60S_HK_1.
• • • • • • • • • • • • • • • • • • • • • • • • C-1 ¥…'RƒW-1 3 6/3/2005, 5:10 PM
• • • • • • • • • • • • • • • • • • • • • • C-2 FU-P60S_HK_1.
• • • • • • • • • HEPA Filter Active Carbon Filter • C-3 FU-P60S_HK_1.
C-4 ¥…'RƒW-1 6 6/3/2005, 5:10 PM
1 2 3 • • • • • • • • • • • C-5 FU-P60S_HK_1.
1 1 2 1 1 2 1 2 1 2 3 C-6 FU-P60S_HK_1.
2 1 2 3 4 5 C-7 FU-P60S_HK_1.
• • • • • • 2 Plasmacluster 1 2 • • • • C-8 ¥…'RƒW-1 10 6/3/2005, 5:11 PM 1
• • • • OPERATION C-9 ¥…'RƒW-1 11 6/3/2005, 5:11 PM
• • • • • • • • • • • • • Plasmacluster • • C-10 FU-P60S_HK_1.
• • • • C-11 FU-P60S_HK_1.
5 1 6 2 • • • • 3 • 7 8 • 4 • C-12 FU-P60S_HK_1.
• • • 1 2 3 • • • • • • C-13 FU-P60S_HK_1.
• • • • • • • • • • • • • • • C-14 FU-P60S_HK_1.
• C-15 FU-P60S_HK_1.
FU-P60S-P30 1 05.6.
MEMO FU-P60S-P31 1 05.6.
SHARP CORPORATION TINS-A154KKRZ 05FO CN 2