CV-P12PX CV-P13PX CV-PD13PX pase)e *.Plasmacluster is a trademark of SHARP Corporation. *Plasmacluster es una marca registrada. de SHARP Corporation.
ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual be kept in a safe place for handy reference. should *FOR CUSTOMER ASSISTANCE (U.S.) oo eeeeeetreees *CONSUMER LIMITED WARRANTY (U.S.) ..0..0.- eee *PRECAUTIONS 0.0... .cccccceccccceeeeeeceeeeeeeeeeeenteeetenneeeseeenneeeeeenneees * LOCATION 0... ceeeeeceeeeeeeeeeeeeeeeeeneeeeennaeeeeenneeesesetteeeeeeneeess oat | NL © a © | Bt De *PART NAMES 0.00...
FOR CUSTOMER ASSISTANCE (the United States) To aid in answering questions if you call for service or for reporting loss or theft, please record below the model and serial number located on the back side of the unit.
ee CONSUMER SOUS yA ae LIMITED WARRANTY FOR THE U.S. USERS This warranty does not apply to any appearance items of the Product nor to the additional excluded item(s) set forth below nor to any Product the exterior of which has been damaged or defaced, which has been subjected to improper voltage or other misuse, abnormal service or handling, or which has been altered or modified in design or construction.
PRECAUTIONS Points to keep in mind when using your air conditioner. WARNINGS FOR USE ¢ Install the air conditioner in accordance with the installation instructions in the latter section of this manual. * Do not modify any part of this product. * Do not insert anything into any part of the unit. * Ensure the power supply used has an appropriate voltage rating. Only use a three-pin grounded electrical AC socket rated 125V, 60Hz, and 15 amps or more as shown on the right.
USAGE CAUTIONS * Ventilate the room periodically during use, especially if using gas appliances. * Be sure to turn the unit off and nance or cleaning. disconnect the power supply cord before performing any mainte- * Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage. oe = * Drainage should be performed whenever moving the air conditioner. If any water remains in the tank, it may spill out while being moved.
PRECAUTIONS OPERATING CONDITIONS ¢ The air conditioner must be operated within the temperature range indicated below. MODE Room temperature Cool Dehumidification 64°F ~ 95°F |59°F ~ 95°F * A built-in safety device may cut off operation if the temperature exceeds these limits. « When cooling operation is performed at high room temperature, the fan may run at a slower speed. ENERGY EFFICIENCY TIPS * Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.
INCLUDED CV-P12PX / CV-P13PX MG Rain deflector 4 | assembly 1 Window exhaust adapter Window slider 1 | bracket 2 Exhaust hose adapter A 1 1 Exhaust hose adapter B Foam seal B 4 | (adhesive type) Split-ring 4 | washer ‘ Washer Window panel assembly t 4 Nut Protective 4 4 Boalt Foam seal A Bracket (0) 4 © 4 Manual screen 4 Large wood screw 5 4 Remote control 3 1 g Screw 2 Battery W(AAA.1.
NM UU to) FRONT VIEW SQAO@QVOOSOW®S (1) Air Outlet REAR VIEW (2) Vertical louvers (3) Horizontal louvers (4) POWER Button (6) Remote control 6) OPERATION Lamp (req) (7) TIMER Lamp (orange) MEGA COOL Lamp (green) (9) PLASMACLUSTER Lamp (blue) Air inlet CV-P12PX CV-P13PX Duct use) 8S CGOSV@OS OWS CV-PD13PX(Single () Exhaust air outlet (2) Window exhaust adapter (3) Exhaust hose adapter A Exhaust hose (5) Remote control hook Air filter (7) Exhaust hose adapter B Cover Grille QQ Air inlet @) Dr
REMOTE CONTROL ® () Transmitter (2) Display (8) POWER Button AIR CONDITIONER (4) LIGHTS Button (6) TEMPERATURE Button WY °F @©rola (6) PLASMACLUSTER BQOVIOPOOVOOSO) FN NEGA COOL ©: AUTO FAN : SLEEP my” Ean! om | Cl ¥ — hes “ates KY Cli) fon age ° oe = PORTABLE Button (7) SLEEP Button MODE Button (Q) ON TIMER Button FAN Button () OFF TIMER Button (2) CANCEL Button (3) LOUVERS Button RESET Button (5) MEGA COOL Button REMOTE CONTROL DISPLAY 8 ® oe © MODE SYMBOLS 3KLb. :COOL G .
INSTALL WINDOW PANEL Installation in a double-hung sash window (CV-P12PX, CV-P13PX) 1 Cut the foam seal A to the proper length and attach it to the window stool. Foam sealA Attach the window exhaust adapter the window panel inside opening. Attach the protective screen to to the outside of the window exhaust adapter. Use 2 screws to attach the protective screen onto the outside exhaust adapter. of the window install the rain deflector to the outside of the window panel.
If the inner width of the window Adjustment panel is between 28" (718mm) and 36.5" (927mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window frame width. (3) ay Secure the window panel to the stool with 3 large wood screws. @ o xr If the inner width of the window is between 36.5" (927mm) and 64" (1625mm) inclusive.
INSTALL WINDOW PANEL Installation in a double-hung sash window (CV-PD13PX) 1 Cut the foam seal A to the proper length and attach it to the window stool. Foam sealA Attach 2 window exhaust adapters the window panel inside opening. to Inside Attach 2 protective screens to the outside of the window exhaust adapter. Use 4 screws to attach the protective screens onto the outside of the window exhaust adapter. install 2 rain deflectors to the outside of the window panel.
lf the inner width of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1) Adjustment panel Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the (3) Secure the window oe = window frame width. panel to the stool with 3 large wood screws. lf the inner width of the window is between 36.5" (927mm) and 64" (1625mm) sive. inclu- (1) Open the window sash and place the second window panel on the window stool.
INSTALL WINDOW PANEL installation in a sliding sash window (CV-P12PX, CV-P13PX) 1 Cut the foam seal A to the proper length and attach it to the window frame. Attach the window exhaust adapter the window panel inside opening. to Inside Attach the protective screen to the outside of the window exhaust adapter. Use 2 screws to attach the protective screen onto the outside exhaust adapter. of the window install the rain deflector to the outside of the window panel.
lf the inner height of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1) Open the window sash and place the window panel on the window frame. 28"~36.5" (2) Slide the adjustment panel to fit the (3) Secure the window panel to the window frame with 3 large wood screws. If the inner height of the window tween 36.5" (927mm) inclusive. (1) oe = window frame height. is be- and 64" (1625mm) Open the window sash and place the window panel on the window frame.
INSTALL WINDOW PANEL installation in a sliding sash window (CV-PD13PX) 1 Cut the foam seal A to the proper length and attach it to the window frame. Foam sealA Attach 2 window exhaust adapters the window panel inside opening. to Attach 2 protective screens to the outside of the window exhaust adapter. Use 4 screws to attach the protective screens onto the outside of the window exhaust adapter. install 2 rain deflectors to the outside of the window panel.
lf the inner height of the window is between 28" (718mm) and 36.5" (927mm) inclusive. (1) Adjustment panel Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to fit the (3) Secure the window panel to the window frame with 3 large wood screws. If the inner height of the window tween 36.5" (927mm) inclusive. (1) oe = window frame height. is be- and 64" (1625mm) Open the window sash and place the window panel on the window frame.
INSTALLATION AND REMOVAL OF EXHAUST HOSE installation of the exhaust hose (CV-P12PX, CV-P13PX) Attach the exhaust and B to the exhaust Extend both ends of and insert them into hose adapters A hose. the exhaust hose the exhaust hose adapters A and B respectively, and turn them until they stop. Make sure they are Exhaust hose adapter A securely attached. Exhaust hose Exhaust hose adapter B 2 Attach the exhaust hose adapter B to the unit.
Attach the exhaust and B to the exhaust Extend both ends of and insert them into wwe hose adapters A hoses. the exhaust hose the exhaust hose adapters A and B respectively, and turn Exhaust hose adapter A them until they stop. Attach the other exhaust hose adapters A and B to the exhaust hose in the same way. Make Exhaust hose sure they are securely attached. Exhaust hose adapter B 2 Cover Attach the exhaust hose adapters B to the unit.
INSTALLATION AND REMOVAL OF EXHAUST HOSE NOTICE: lf the dual-duct type unit is used as single-duct type one, please refer to the following instructions: Attach the grille and the cover to the unit. Open the baffle and remove it. Insert the 2 projections on the grille into the 2 holes on the back plate of the unit, and close the grille. insert the two projections on the cover into the two holes on the unit, 2 install one exhaust hose.
Removal of the exhaust hose Remove the exhaust hose adapter A. Remove the exhaust hose adapter A oe = from the window exhaust adapter. Window exhaust adapter Remove the exhaust from the unit. Lift up and remove hose adapter the exhaust hose adapter from the unit by pushing on the two projections.
PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. Always check the power plug before use. 1 Press the RESET button. Insert the power plug into the wall socket. Press the TEST button. You will hear a CLICK if the circuit breaker is functioning correctly. Press the RESET button until you hear another CLICK. The circuit breaker is activated, power is supplied, and the air conditioner is now ready for use.
HOW TO USE THE REMOTE CONTROL oe = Point the remote control towards the units signal receiver window and press the desired button. A beep will sound when the unit re- ceives the signal. ¢ Make sure nothing, such as curtains, blocks the signal receiver window. « The remote control operates up to 23 feet (7 meters) away. CAUTION ¢ Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary, close the curtains to block out the sunlight.
COOL MODE Ensure that the stopcock is securely attached the drainpipe. Press the MODE button to select COOL mode. COOL DEHUM ~~ FAN VENT alle PORTABLE AIR CONDITIONER Pia i { GND * ( a alin. > yy > > = ) Press the POWER button to start operation. « The red OPERATION lamp on the unit will light. Press the TEMPERATURE button to set the desired temperature. fa « The temperature can be set within the range of MEGA COOL oe o @r| < ON TIMER RESEY QO: OFF TIMER 64°F to 86°F.
in this mode, the air conditioner simply circulates the air without cooling it. Ensure that the stopcock is securely attached the drainpipe. mode. PORTABLE AIR CONDITIONER alle ae Press the POWER button to start operation. « The red OPERATION lamp on the unit will light. « The temperature cannot be set. Press the FAN button to set the desired speed.
TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION Press the LOUVERS button on mote control. « The horizontal louvers will swing ously. & gegey continu- position. oo MEGA COOL re- Press the LOUVERS button again when the horizontal louvers are at the desired LOU Mi ERS CANTO FAN 2: SLEEP the Ob | ON TIMER « The horizontal louvers will stop moving. OPO: OFF TIMER « The adjusted position will be memorized and the same position will be set when operated the next time.
PLASMACLUSTER Plasmacluster ions released OPERATION into the room 1 Press will reduce some the airborne PLASMACLUSTER mold. button during operation. « fon 1” “egg e « The blue PLASMACLUSTER light. I lamp on the unit will TO CANCEL Press the PLASMACLUSTER « The off. PLASMACLUSTER button again. lamp on the unit will turn NOTES: NEGA COOL ©: AUTO FAN SLEEP \o:2): SLEEP @p | ON TIMER OO: OFF TIMER Use of the PLASMACLUSTER function will be memorized and it will be activated the next ti
MEGA COOL OPERATION In this operation, the air conditioner temperature of 59°F. (eS 1 PORTABLE AIR CONDITIONER fan works at extra high speed with a setting Press the MEGA COOL button during cooling mode. * The remote control will display "S& if « The temperature display will go off. « The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. 1 « MEGA CCOL operation is also cancelled when the mode is changed, or when the unit is turned off.
TIMER OPERATION ON TIMER Press the ON TIMER button. « The time setting will change as you press the button ep RUAOLE AIR CONDITIONER | «a as follows. Hold the button down to speed through the settings. Crore On 1 Shepton oe Hine 12h « The orange TIMER lamp on the unit will light. « The time setting will count down to show the remaining time. Select the mode, temperature, fan speed ‘setting and PLASMACLUSTER operation. as. desired.
MAIN UNIT OPERATION Use this mode when the remote control is not available. Press the POWER button on the unit. « The red OPERATION lamp on the unit will light. 1 * if the unit has not been unplugged since it was last operated, it will resume operation at its last settings. « If the unit has been unplugged since it was last operated, it will resume operation in the cooling mode, set at 68°F. The fan speed set to AUTO. TO TURN OFF Press the POWER « The off. button again.
MAINTENANCE Be sure to disconnect the power from the wall socket before performing any maintenance. CLEANING THE FILTER resulting in poor cooling oe = if the filter is clogged with dust, the airflow will be reduced, performance. The filter should be cleaned every two weeks. AIR FILTER REMOVE THE FILTER « Gently pull the filter handle slide the filter out of the unit. to the right and CLEAN THE FILTER « Use a vacuum cleaner to remove any dust.
BEFORE CALLING FOR SERVICE lf the unit appears for a service.