ENGLISH This manual explains the proper use of your new air conditioner. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference. CONTENTS • USAGE CAUTIONS .....................................................................E-2 • PRECAUTIONS ......................................................................E-3 • LOCATION ...............................................................................E-3 • INCLUDED.......................
USAGE CAUTIONS • Ventilate the room periodically during use, especially if using gas appliances. • Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance or cleaning. • Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage. • Remove the window panel and close the window in the event of particularly adverse weather. Extremely adverse weather may cause water to leak in through the openings.
PRECAUTIONS OPERATING CONDITIONS • The air conditioner must be operated within the temperature range indicated below. MODE Room temperature 18°C ~ 35°C Cool 15°C ~ 35°C Dehumidification • A built-in safety device may cut off operation if the temperature exceeds these limits. • When cooling operation is performed at high room temperature, the fan may run at a slower speed. ENERGY EFFICIENCY TIPS • Avoid direct sunlight. Close blinds, drapes or shades to keep out direct sunlight while in cooling mode.
INCLUDED Exhaust hose Manual Rain guard 1 Window exhaust adapter 1 Exhaust hose adapter 1 1 Foam seal B 1 (adhesive type) 1 Extension panel 1 2 Insect guard net 1 Foam seal A Bracket Remote control 1 Battery (AAA.1.5V) 2 1 3 Screw 8 SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. Screwdriver(medium size Phillips) 2. Tape measure or ruler 3. Knife or scissors 4. Saw (In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation.
PART NAMES FRONT VIEW 1 1 Air Outlet 2 2 Vertical louvers 3 3 Horizontal louvers 4 4 POWER Button 5 5 Remote control signal receiver window 6 7 8 9 0 0 REAR VIEW 6 OPERATION Lamp (red) 7 TIMER Lamp (orange) 8 MEGA COOL Lamp (green) 9 PLASMACLUSTER Lamp (blue) 0 Air inlet Remote control hook q w w Window exhaust adapter e Exhaust hose e r t y u i o p a r Remote control hook s a Power plug s Casters(4) NOTE: Actual unit might vary slightly from above illustration.
REMOTE CONTROL 1 1 Transmitter 2 Display ENGLISH 3 POWER Button 4 LIGHTS Button 2 5 TEMPERATURE Button 3 4 5 6 7 8 9 0 q w e r t 6 PLASMACLUSTER Button 7 SLEEP Button 8 MODE Button 9 ON TIMER Button 0 FAN Button q OFF TIMER Button w CANCEL Button e LOUVERS Button r RESET Button t MEGA COOL Button REMOTE CONTROL DISPLAY y MODE SYMBOLS : COOL : DEHUMIDIFICATION y : FAN u i o : VENTILATION p u MEGA COOL SYMBOL i PLASMACLUSTER SYMBOL a o FAN SPEED SYMBOLS : AUTO : Quiet : Low : High s d p TEM
INSTALL WINDOW PANEL Installation in a double-hung sash window (See page 9 for installation in a sliding sash window. ) Hole the rain guards to the insect 1 Connect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be uppermost, as indicated in the diagram. "A" Projection Attach the guard combined above to the panel 2 window Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.
Adjustment panel If the inner width of the window is between 24" (609mm) and 36.8" (934mm) inclusive. (1) Open the window sash and place the window panel on the window stool. (2) Slide the adjustment panel to fit the window frame width. 24"~36.8" (3) Secure the window panel to the stool with 3 screws. If the inner width of the window is between 36.8" (934mm) and 48" (1219mm) inclusive. Extension panel (1) Attach the extension panel to the adjustment panel.
INSTALL WINDOW PANEL Installation in a sliding sash window "A" the rain guards to the insect 1 Connect guard net. Insert all three projections on each rain guard into the holes in the insect guard net. Side “A” will now be uppermost, as indicated in the diagram. Insect guard net Hole the guard combined above to the window panel. 2 Attach Push the insect guard net firmly to ensure that its four projections fit into the holes in the window panel.
If the inner height of the window is between 24" (609mm) and 36.8" (934mm) inclusive. Adjustment panel (1) Open the window sash and place the window panel on the window frame. (2) Slide the adjustment panel to fit the window frame height. 24"~36.8" (3) Secure the window panel to the window frame with 3 screws. Extension panel If the inner height of the window is between 36.8" (934mm) and 48" (1219mm) inclusive. (1) Attach the extension panel to the adjustment panel. 36.
INSTALLATION AND REMOVAL OF EXHAUST HOSE The exhaust hose must be installed or removed in accordance with the usage mode. MODE EXHAUST HOSE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container Install DEHUMIDIFICATION with container Remove Installation of the exhaust hose the window exhaust adapter to 1 Attach the exhaust hose. Extend one end of the exhaust hose and insert it into the window exhaust adapter, and turn it (approx. three times) until it stops.
Removal of the exhaust hose Remove the window exhaust adapter. 1 Pull out and remove the window exhaust adapter by pushing down two “PUSH” markings, and slide and close the exhaust cover in the window panel. "PUSH" Remove the exhaust hose adapter from 2 the unit. Lift up and remove the exhaust hose adapter from the unit by pushing down on the two projections.
PRE-OPERATION CHECKS LOADING BATTERIES Use two AAA (R03) batteries. the battery cover at the 1 Remove back of the remote control. batteries into the com2 Insert partment, making sure the ± and — polarities are correctly aligned. • Lines will appear on the display when batteries are properly installed. 3 Reattach the battery cover. the RESET button using 4 Press a thin pointed implement. Battery cover NOTES: • The battery should last approximately one year under normal use.
HOW TO USE THE REMOTE CONTROL ENGLISH Point the remote control towards the units signal receiver window and press the desired button. A beep will sound when the unit receives the signal. • Make sure nothing, such as curtains, blocks the signal receiver window. • The remote control operates up to 23 feet (7 meters) away. CAUTION • Do not expose the signal receiver window to direct sunlight. This may adversely affect its operation. If necessary, close the curtains to block out the sunlight.
COOL MODE Ensure that the stopcock is securely attached the drainpipe. Stopcock Drainpipe Press the MODE button to select COOL 1 mode. COOL 2 3 1 4 DEHUM FAN VENT Press the POWER button to start opera2 tion. • The red OPERATION lamp on the unit will light. Press the TEMPERATURE button to set 3 the desired temperature. • The temperature can be set within the range of 18°C to 30°C. Press the FAN button to set the desired 4 fan speed. AUTO QUIET LOW HIGH TO TURN OFF Press the POWER button again.
FAN MODE In this mode, the air conditioner simply circulates the air without cooling it. Ensure that the stopcock is securely attached to the drainpipe. 1 Press the MODE button to select FAN mode. COOL 2 DEHUM FAN VENT 2 Press the POWER button to start operation. Press the FAN button to set the desired fan 3 speed. • The red OPERATION lamp on the unit will light. • The temperature cannot be set. 1 3 QUIET LOW HIGH TO TURN OFF Press the POWER button again.
TO CHANGE AIR FLOW DIRECTION UP / DOWN AIR FLOW DIRECTION Press the LOUVERS button on the re1 mote control. • The horizontal louvers will swing continuously. 1 2 the LOUVERS button again when 2 Press the horizontal louvers are at the desired position. • The horizontal louvers will stop moving. • The adjusted position will be memorized and the same position will be set automatically when operated the next time. NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be changed.
PLASMACLUSTER OPERATION Plasmacluster ions released into the room will reduce some airborne mold. Press the PLASMACLUSTER button during 1 operation. ”. • The blue PLASMACLUSTER lamp on the unit will light. TO CANCEL 1 Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off. NOTES: • Use of the PLASMACLUSTER function will be memorized and it will be activated the next time you turn on the air conditioner. • To turn off the PLASMACLUSTER Lamp, press the LIGHTS button.
MEGA COOL OPERATION In this operation, the air conditioner fan works at extra high speed with a setting temperature of 15°C. Press the MEGA COOL button during cooling 1 mode. • The remote control will display " ". • The temperature display will go off. • The green MEGA COOL lamp on the unit will light. TO CANCEL Press the MEGA COOL button again. 1 • MEGA COOL operation is also cancelled when the mode is changed, or when the unit is turned off. • The green MEGA COOL lamp on the unit will turn off.
TIMER OPERATION ON TIMER 1 Press the ON TIMER button. • The orange TIMER lamp on the unit will light. • The time setting will count down to show the remaining time. 1 CANCEL Select the mode, temperature, fan speed setting and PLASMACLUSTER operation as desired. • When the temperature is set with the ON TIMER, the temperature will show in the display for 5 seconds and then return to the time display. • If you do not change the setting, the unit will operate using the most recent setting.
MAIN UNIT OPERATION Use this mode when the remote control is not available. 1 1 Press the POWER button on the unit. • The red OPERATION lamp on the unit will light. • If the unit has not been unplugged since it was last operated, it will resume operation at its last settings. • If the unit has been unplugged since it was last operated, it will resume operation in the cooling mode, set at 20˚C. The fan speed set to AUTO. TO TURN OFF Press the POWER button again.
MAINTENANCE Be sure to disconnect the power from the wall socket before performing any maintenance. CLEANING THE FILTER AIR FILTER 1 REMOVE THE FILTER • Gently pull the filter handle to the right and slide the filter out of the unit. Air filter 2 CLEAN THE FILTER Air inlet filter • Use a vacuum cleaner to remove any dust. If the filter is very dirty, wash it with detergent and rinse carefully with clean water. Dry the filter in the shade before reinstalling them.
BEFORE CALLING FOR SERVICE If the unit appears to be malfunctioning, check the following points before calling for a service.
Technical Specifications Sr Parameter No 1 2 Unit Model Power Supply Value CV-P10LJ Rated Voltage V~ 220-240 Rated Frequency Hz 50 Phases 1 3 Cooling Capacity W 2930 4 Cooling Power Input W 1100 5 Cooling Power Current A 4.80 6 Rated Input W 1250 7 Rated Current A 5.80 8 Air Flow Volume(H/M/L) 3 m /h 350/260/180 9 Dehumidifying Volume L/h 1 10 EER W/W 2.
28 Refrigerant R410A 29 Refrigerant Charge 30 Compressor 31 Compressor Model 32 33 kg LANDA COMPRESSOR QXA-B102T130 Compressor Oil Compressor 0.67 RB68EP Compressor Type Rotary 34 L.R.A. A 19.00 35 Compressor RLA A 3.90 36 Compressor Power Input W 850 37 Fan Type 38 Diameter Length(DXL) mm φ227 X 109 39 Fan Motor Speed(H/ML) r/min 950/750/500 40 Output of Fan Motor W 40 41 Fan Motor RLA A 0.46 Fan Motor Capacitor μF 3.
Technical Specifications Sr No 1 2 Parameter Unit Model Power Supply Value CV-P13LJ Rated Voltage V~ 220-240 Rated Frequency Hz 50 Phases 1 3 Cooling Capacity W 3550 4 Cooling Power Input W 1360 5 Cooling Power Current A 6.00 6 Rated Input W 1550 7 Rated Current A 7.20 8 Air Flow Volume(H/M/L) 3 m /h 350/260/180 9 Dehumidifying Volume L/h 1 10 EER W/W 2.
Refrigerant R410A 29 Refrigerant Charge 30 Compressor 31 Compressor Model 32 Compressor kg 0.95 MITSUBISHI RN125VHFMC Compressor Oil PVE(FV50S or similar) 33 Compressor Type 34 L.R.A. A 23.00 35 Compressor RLA A 4.70 36 Compressor Power Input W 1030 37 Fan Type 38 Diameter Length(DXL) mm φ227 X 109 39 Fan Motor Speed(H/ML) r/min 950 / 800 / 600 40 Output of Fan Motor W 40 41 Fan Motor RLA A 0.46 Fan Motor Capacitor μF 3.
WARRANTY Consumer Electronic Products Congratulations on Your Purchase! This Sharp product is warranted against faults in materials and manufacture for a period of twelve (12) months from the date of original purchase. (excluding lamps and air filters. ) If service is required during the warranty period, please contact your nearest Sharp Approved Service Centre. These repairs would be carried out at no charge to the owner, subject to the conditions specified herein.
SHARP FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.au OR CALL SHARP CUSTOMER CARE 1300 135 022 (LOCAL CALL COST APPLY WITHIN AUSTRALIA) SHARP CORPORATION OF AUSTRALIA PTY LTD SHARP FOR LOCATION ENQUIRIES WITHIN NEW ZEALAND REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE VISIT OUR WEBSITE AT www.sharp.net.
SHARP CORPORATION OF AUSTRALIA PTY LTD ABN 40 003 039 405 1 Huntingwood Drive HUNTINGWOOD NSW 2148 www.sharp.net.