SERVICE MANUAL CODE: 00ZAR203E/S2E DIGITAL MULTIFUNCTIONAL SYSTEM/DIGITAL COPIER MODEL AR-203E AR-203E X AR-M200 AR-M201 AR-5420 (The descriptions of the AR-203E X are same as those of the AR-203E unless otherwise specified.) CONTENTS [1] GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 1 [2] SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 1 [3] CONSUMABLE PARTS . . . . . . . . . . . . . . . . . . . . . . . .
CAUTION This product is a class 1 laser product that complies with 21CFR 1040 of the CDRH standard and IEC825. This means that this machine does not produce hazardous laser radiation. The use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. This laser radiation is not a danger to the skin, but when an exact focusing of the laser beam is achieved on the eye’s retina, there is the danger of spot damage to the retina.
At the production line, the output power of the scanner unit is adjusted to 0.18 MILLI-WATT PLUS 20 PCTS and is maintained constant by the operation of the Automatic Power Control (APC). Even if the APC circuit fails in operation for some reason, the maximum output power will only be 15 MILLI-WATT 0.1 MICRO-SEC. Giving and accessible emission level of 42 MICRO-WATT which is still-less than the limit of CLASS-1 laser product. Caution This product contains a low power laser device.
CONTENTS [1] [2] [3] GENERAL [7] 1. Outline of operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1 SPECIFICATIONS 2. Scanner section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 1. Basic Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 A. Scanner unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2 2. Operation specifications . . . . . . . . . . . . . . . . . . . . . . . . 2-1 B. Optical system . . . . . . . . . . . . .
8 Power section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-20 1. Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-1 B. Disassembly procedure . . . . . . . . . . . . . . . . . . . . . 8-20 A. Overall block diagram (AR-203E/5420) . . . . . . . . . 13-1 C. Assembly procedure. . . . . . . . . . . . . . . . . . . . . . . . 8-20 B. Overall block diagram (AR-M200/M201) . . . . . . . . 13-2 9. DV unit section . . . . . . . . . . . . . . . . . . . . . . . . .
[1] GENERAL 1. Major functions Configurations Item CPM (A4) PPM (A4) Model AR-203E 20CPM 15PPM SB/ MB MB 2 Tray SPF R-SPF Opt Color GDI SPLC EDuplex Shifter Scanner printer printer SORT ✕ Opt — AR-5420 20CPM AR-M200 20CPM 20PPM MB MB ✕ Opt ✕ ✕ ✕ Opt AR-M201 20CPM 20PPM MB Opt ✕ Opt ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ ✕ USB ✕ ✕ (2.0 full) ✕ RJ45 FAX External NIC ✕ ✕ ✕ ✕ ✕ ✕ Opt ✕ Opt ✕ Opt Opt (2.0 Hi) ✕ (2.
[2] SPECIFICATIONS 1. Basic Specifications Item Type Copy system Segment (class) Copier dimensions Weight (Approximately) Desktop Dry, electrostatic Digital personal copier AR-203E/5420: 518mm (W) x 445mm (D) x 298mm (H) (20-1/2" (W) x 17-5/8" (D) x 11-3/4" (H)) AR-M200/M201: 518mm (W) x 452mm (D) x 298mm (H) (20-1/2" (W) x 17-7/8" (D) x 11-3/4" (H)) AR-203E/5420: 16.6kg (36.5 lbs.) Toner cartridge not included AR-M200: 19.8kg (43.7 lbs.) AR-M201: 20.5kg (45.2 lbs.) 2.
Fusing section Electrical section Section, item Fusing system Upper heat roller Lower heat roller Heater lamp Details Power source Power consumption Type Type Type Voltage Power consumption Voltage Frequency Max.
4. GDI printer (AR-203E only) Print speed Max. 15ppm (excluding bypass tray, paper size A4, 8.5" x 11") (Variable depending on the PC performance) Duplex No Memory 8MB Interface USB 2.0 (Full speed) Emulation GDI Resolution 600dpi *1 Supported OS Win 98 / Me / 2000 / XP / Vista WHQL support Yes *2 *1: Engine Resolution *2: By running change 5. SPLC printer (AR-M200/M201) Print speed Max. 20ppm (Paper size: A4, excluding manual paper feed) ∗ Varies depending on the PC performance.
[3] CONSUMABLE PARTS 1. Supply system table A. Europe Subsidiary (AR-203E/5420/M200/M201), SCA/SCNZ (AR-203E/M201) No.
2. Environmental The environmental conditions for assuring the copy quality and the machine operations are as follows: (1) 3. Production control number (lot No.) identification Normal operating condition Temperature: 20 - 25°C Production month Production day Destination code Humidity: 65 ± 5%RH (2) Acceptable operating condition (Dealer, distributor, OEM, etc.) Production place (SOCC: Fixed to B.) End digit of year Version No.
Sub lot Production day Production month End digit of year Production place 4. Toner cartridge replacement 1) Open the front and side cabinets of the copier. 2) Keep holding Toner lever, and 3) Carefully pull out Toner unit from the copier. 2 3 1 4) Put Toner unit in a collection bag immediately after removing it from the copier Note: Never carry exposed Toner unit. Be sure to put it in the collection bag.
[4] EXTERNAL VIEWS AND INTERNAL STRUCTURES 1. Appearance Interface Interface 1 USB connector (AR-203E) USB connector (AR-M200/M201) 2 3 7 10 11 8 9 4 5 12 13 14 6 1 4 7 10 13 Original cover Front cover Side cover Paper output tray Handle 2 5 8 11 14 Document glass Paper tray Side cover open button Paper output tray extension Power cord 3 6 9 12 Operation panel Multi-bypass tray Bypass tray paper guides Power switch 2.
3. Operation panel A. AR-203E/5420 1 2 3 4 5 6 13 14 1 3 5 7 9 11 13 15 17 Exposure mode selector key and indicators Use to sequentially select the exposure modes: AUTO, MANUAL or PHOTO. Selected mode is shown by a lit indicator.
Power save indicator 2) Place the original you wish to scan on the document glass/ SPF. On: Indicates the unit is in a power save mode. Blinking: Indicates that the unit is initializing (when the side cover is opened and closed or the power turned off and on). 3) Press the right copy quantity key to display the number of the application that you wish to use for scanning. The application numbers are initially as follows.
1 [MODE SELECT] key / Mode indicators Press this key to select the mode. The indicator of the selected mode lights (copy, printer, scanner, fax indicators). 2 3 Numeric keys Use these to enter the number of copies and other numerical settings. 4 5 7 9 11 13 15 17 The keys can also be used to select items in function setting menus. Power save indicator This lights up when the power save function is activated.
4. Motors and solenoids 2 4 1 5 9 7 6 8 No. 1 2 3 4 5 6 7 8 9 Part name Main motor Scanner motor Toner motor Cooling fan motor Resist roller solenoid Paper feed solenoid Multi paper feed solenoid Duplex motor Shifter motor Control signal MM MRMT TM VFM RRS CPFS1 MPFS DMT SFTM 3 Function / Operation Drives the copier. Drives the optical mirror base (scanner unit). Supplies toner. Cools the optical, fusing section.
5. Sensors and switches 2 1 3 4 5 6 7 No.
6. PWB unit 2 5 11 1 8 9 6 10 4 3 7 No.
7. Cross sectional view 1 2 4 3 16 5 15 6 7 8 9 10 14 No.
[5] UNPACKING AND INSTALLATION 1. Copier installation 2. Cautions on handling Improper installation may damage the copier. Please note the following during initial installation and whenever the copier is moved. Be careful in handling the copier as follows to maintain the performance of this copier. Caution: If the copier is moved from a cool place to a warm place, condensation may form inside the copier. Operation in this condition will cause poor copy quality and malfunctions.
4. Unpacking Be sure to hold the handles on both sides of the unit to unpack the unit and carry it to the installation location. 2) Remove the CAUTION tape from the front cover and remove the two protective pins from the fusing unit by pulling the strings upward one at a time. Protective pins CAUTION tape 3) Push gently on both sides of the front cover to open the cover. 5. Removing protective packing materials 1) Remove all pieces of tape shown in the illustration below.
9) Shake the aluminum bag to stir developer. 10) Supply developer from the aluminum bag to the top of the MX roller evenly. 7. Toner cartridge installation 1) To prevent against uneven distribution of toner, hold Toner unit with both hands and shake it several times horizontally. 2) Hold the section of Toner unit shown in the figure below, remove the packing tape, and remove the cushion. 3) Pull out the cushion in the arrow direction. Note: Be careful not to splash developer outside Developer unit.
8. Loading paper 10. Software (AR-203E/M200/M201) 1) Raise the handle of the paper tray and pull the paper tray out until it stops. The CD-ROM that accompanies the machine contains the following software: MFP driver Printer driver The printer driver enables you to use the printer function of the machine. 2) Remove the pressure plate lock. Rotate the pressure plate lock in the direction of the arrow to remove it while pressing down the pressure plate of the paper tray.
B. Installing the software 8) Click the "MFP Driver" button. Note: • The screen images in this manual are mainly for Windows XP. With other versions of Windows, some screen images may be different from those in this manual. Click the "Display Readme" button to show information on packages that are selected. • In the following explanations it is assumed that the mouse is configured for right hand operation. • If an error message appears, follow the instructions on the screen to solve the problem.
Installing the Utility Software 11) Click the "Button Manager" or the "Sharpdesk" button. Click the "Display Readme" button to show information on packages that are selected. Follow the on-screen instructions. 14) Follow the instructions in the plug and play window to install the driver. Follow the on-screen instructions. Caution: • If you are using Windows Vista and a security warning window appears, be sure to click "Install this driver software anyway".
(2) Using the machine as a shared printer (AR-203E/M200/M201) 5) Click the "Add Network Port" button. In Windows Vista, the "Add Network Port" button does not appear. If the machine will be used as a shared printer on a network, follow these steps to install the printer driver in the client computer. Note: To configure the appropriate settings in the print server, see the operation manual or help file of your operating system. 1) Perform steps 2) through 6) in "Installing the software".
2) Click the "SHARP AR-XXXX" icon and select "Properties" from the "File" menu. In Windows Vista, select "Properties" from the "Organize" menu. 3) In the "Properties" screen, click the "Events" tab. 4) Select "SC1:" from the "Select an event" pull-down menu. (2) Windows 98/Me/2000 1) Click the "Start" button, select "Settings", and then click "Control Panel". 2) Double-click the "Scanners and Cameras" icon.
11. Interface 13. Scanner moisture-proof kit A. USB If the machine is installed in a highly humid environment, you can alleviate dew condensation inside the scanner by installing the scanner moisture-proof kit described below. Connector Type-B connector A. Components Cable Scanner moisture-proof kit (DKIT-0016QSZZ) Shielded twisted pair cable (2 m (6 feet) Max.: high-speed transmission equivalent) 1 Pin configuration The pin numbers and signal names are listed in the following table. Pin No.
3) Remove the rear cover for the document glass. <1> Remove the two screws and then remove the right glass holder. Attach along the edge of the projection (the yellow line in the diagram below). <2> Slide the rear cover for the document glass to remove it. <3> Remove the table glass. 1 2 3 5) Attach the Optical right hole mylar B at the 2 positions shown in the diagrams below which are at the top of the rear side of the main unit. Note: The holes should be covered with the mylar.
6) Attach the Scanner motor metal plate cushion at 1 position on the attachment plate of the motor on the rear side of the main unit. Bend the part which is sticking out to the rear side of the scanner and attach to the surface. Note: The hole on the top of the motor unit should be covered with the mylar. Align the edge of the metal plate and the edge of the cushion (the yellow line in the diagram below). Press the cushion at the steps shown in the diagram so that there will be no gap.
10) Attach the Scanner motor metal plate cushion covering the bottom part of the Scanner motor lower mylar. Note: The hole under the motor unit should be covered. Attach the cushion to cover the gap between the mylar and the metal plate (the yellow mark). Stick the lower part of the cushion to the mylar, too. 13) Attach the Fan housing cushion to the cooling fan at the position shown in the diagram below.
[6] COPY PROCESS An OPC drum is used for the photoconductor. (Structure of the OPC drum layers) OPC layer (20 microns thick) Pigment layer (0.2 to 0.3 microns thick) Aluminum drum 1.
2. Outline of print process Step-2: Exposure (laser beam, lens) This printer is a non-impact printer that uses a semiconductor laser and electrostatic print process. This printer uses an OPC (Organic Photo Conductor) for its photoconductive material. First, voltage from the main corona unit charges the drum surface and a latent image is formed on the drum surface using a laser beam. This latent image forms a visible image on the drum surface when toner is applied.
Step-3: Developing (DC bias) Step-4: Transfer A bias potential is applied to the MG roller in the two component magnetic brush developing method, and the toner is charged negative through friction with the carrier. The visible image on the drum surface is transferred onto the print paper by applying a positive charge from the transfer corona to the backside of the print paper.
Step-7: Optical discharge (Semiconductor laser) Start Before the drum rotation is stopped, the semiconductor laser is radiated onto the drum to reduce the electrical resistance in the OPC layer and eliminate residual charge, providing a uniform state to the drum surface for the next page to be printed. 1) Because the grid potential is at a low level, the drum potential is at about -400V. (Carrier may not be attracted though the carrier is pulled towards the drum by the electrostatic force of 400V.
[7] OPERATIONAL DESCRIPTIONS 1. Outline of operation The outline of operation is described referring to the basic configuration.
2. Scanner section A. Scanner unit Spectral sensitivity characteristics (Standard characteristics) The scanner unit in the digital copier scans images. Relative sensitivity It is composed of the optical unit and the drive unit. The optical unit performs scanning in the main scan direction with the light receiving elements (color CCD). The drive unit performs scanning in the sub scanning direction by moving the optical unit. B. Optical system Two white lamps are used as the light source.
3. Laser unit B. Laser beam path The image data sent from the MCU (image process circuit) is sent to the LSU (laser unit), where it is converted into laser beams. A. Basic structure The LSU unit is the writing section of the digital optical system. The semiconductor laser is used as the light source, and images are formed on the OPC drum by the polygon mirror and fθ lens, etc.
A. General description 2) The surface temperature of the upper heat roller is set to 160 200°C. The surface temperature during the power save mode is set to 100°C. General block diagram (cross section) Thermal fuse Separator pawl PPD2 3) The self-check function comes active when one of the following malfunctions occurs, and an "H" is displayed on the multicopy window. a. When the heat roller surface temperature rises above 240°C. b.
(1) Cassette paper feed operation 1) The figure below shows the positions of the pick-up roller, the paper feed clutch sleeve, and the paper feed latch in the initial state without pressing the COPY button after lighting the ready lamp. The paper feed latch is in contact with the projection of the clutch sleeve. 2) When the COPY button is pressed, the main drive motor starts rotating to drive each drive gear. The pick-up drive gear also is driven at that time.
(2) Manual multi paper feed operation 1) Before paper feed operation, the manual paper feed solenoid (MPFS) is turned OFF as shown in the figure below. C 3) When pawl C of the manual paper feed clutch sleeve is engaged with the manual feed latch, the manual feed stopper falls and the manual take-up roller rises. At that time, the manual paper feed roller is rotating.
(3) Conditions of occurrence of paper misfeed a. When the power is turned on: PPD or POD is ON when the power is turned on. b. Copy operation a PPD1 jam b PPD2 jam c POD jam PPD1 does not turn off within 4 sec after turning on the resist roller. PPD2 is off immediately after turning on the resist roller. PPD2 does not turn off within 1.2 sec after turning off the resist roller. POD does not turn on within 2.9 sec after turning on the resist roller. POD does not turn off within 1.5 sec - 2.
Rotation copy mode: The front and the back are in upside down each other. Copy mode without rotation: The front and the back are not in upside down. 7. Shifter (AR-M200/M201) Shift width: 2.5cm The offset function by the shifter is turned ON/OFF by the user program. According to the setting, offset operation is performed for every job.
[8] DISASSEMBLY AND ASSEMBLY 2) Remove the drum fixing plate and the photoconductor drum. (Note) Dispose the drum fixing plate which was removed. Before disassembly, be sure to disconnect the power cord for safety. 1. Do not disconnect or connect the connector and the harness during the machine is powered. Especially be careful not to disconnect or connect the harness between the MCU PWB and the LSU (MCU PWB: CN119) during the machine is powered.
6) Clean the cleaning section and the waste toner pipe to remove waste toner completely with a vacuum cleaner. Normal state of the molt • Machine F side 7) Remove the felt and duplex tape completely. Note: Be careful not to scratch or bend the sub blade. 8) Attach the cleaning blade. Securely insert the plate section of the cleaning blade into the unit and fix it with a screw. Do not touch the cleaning blade rubber with your hand.
C. Disassembly procedure 10) Attach the main charger. Securely set the MC holder on the projection of the process frame. 1) Press the side cover open/close button and open the side cover. Securely insert two projections of the MC holder into the groove in the process frame. When attaching the MC holder ass'y, be careful not to make contact with the cleaning blade. 1) 2) 11) Attach the drum fixing plate and the photoconductor drum. Apply grease to the inside of the photoconductor drum. (Dia.
E. Charger wire cleaning F. Charger wire replacement 1) Remove the charger cleaner from the manual paper feed unit. 1) Remove the TC cover and remove the screw. 2) Remove the spring and remove the charger wire. 3) Install a new charger wire by reversing the procedures (1) and (2). At that time, be careful of the following items. • The rest of the charger wire must be within 1.5mm. Refer to Fig.1 • The spring hook section (charger wire winding section) must be in the range of the projection section.
2) Remove the screws (4 pcs.), the harness, and the operation panel unit. (AR-M200/M201) 1) 3) 2) 1) 2) 1) 5) 5) 5) 5) 4) 2) 1) 1) 3) Remove four screws, and remove the operation cabinet. 4) Remove four screws, and remove the operation PWB. (AR-203E/5420) C. Assembly procedure For assembly, reverse the disassembly procedure 2) 1) 3. Optical section A. List 1) NO. 1 2 3 1) 3) 3) 3) 1) 3) 3) B. Disassembly procedure 3) 4) 3) Part name Ref.
2) Remove two screws, and remove the earth wire. 10) Move the carriage to the position indicated on the figure. 3) Disconnect the connector. 11) Loosen the screw which is fixing the tension plate. 4) Remove the original cover. 12) Move the tension plate in the arrow direction to release the tension, and remove the belt. 3) 2) 4) 1) 13) Remove the screw, and remove the rod stopper. 14) Remove the rod. 3) 5) Remove five screws. Remove the operation unit, and disconnect the connector.
C. Assembly procedure 4. Fusing section CCD core A. List 1) Insert the CCD-MCU harness into the CCD PWB of the carriage unit. 2) Attach the CCD-MCU harness to the duplex tape on the back surface of the carriage unit. Clean and remove oil and dirt from the attachment surface. 3) Pass the CCD-MCU harness through the square hole in the base plate. 4) Attach the CCD-MCU harness to the base plate with duplex tape. 5) Attach two cable fixing sheets to fix the CCD-MCU harness to the base plate.
4) Remove the screw and remove the U-turn guide. 7) Remove the plate spring on the right and remove the heater lamp. 1) 2) 1) 2) Pressure roller section disassembly 5) Remove the three screws, remove the fusing cover lower on the right side, and open the heat roller section. Heater lamp 2) 3) 4) 8) Remove the spring, and remove the upper separation pawls (3 pcs.). 6) 3) 5) 1) 5) 2) 6) 6) Remove the screw and remove the PPD2 sensor.
10) Remove the spring, and remove the lower separation pawls (4 pcs.). Heat roller disassembly (Continued from procedure (4).) 5) Remove screws, remove the fusing cover, and open the heat roller section. 2) 3) 2) 2) 2) 2) 1) 1) 3) 2) 11) Remove the pressure release levers on the right and the left sides. 6) Remove the C-ring and the fusing bearing, and remove the heat roller. 1) 2) Heat roller 3) 1) 1) 7) Remove the parts from the heat roller.
2) Remove two screws, and remove the hinge guide R. 3) Disconnect the connector. (2 positions) 4) Remove five screws, and remove the scanner unit. 1) 5) Remove the fan duct. 2) 2) 3) 2) 2) 2) 2) 2) 3) 1) 2) C. Assembly procedure For assembly, reverse the disassembly procedure. 5. Tray paper feed/transport section 6) Remove the connector and the screw, and remove the speaker unit. (When the AR-FX13 is installed) A. List No. 1 2 3 4 5 Part name Ref.
9) Remove each connector and four screws, and remove the MCU PWB. (The shape of the MCU PWB differs depending on the model.) 11) Remove two springs and open the intermediate frame unit. (AR-203E/5420) 1) 3) 2) 1) 2) 2) 1) 1) 1) 1) 1) 2) 10) Remove the PWB insulation mylar and remove the paper transport detection sensor (POD). 1) 12) Remove the screw, and open the upper paper guide. (AR-M200/M201) 1) 1) 2) 2) 13) Remove the roller, and remove the belt.
14) Remove the pulleys on the both sides and remove the paper exit roller. (AR-203E/5420) 18) Remove the harness guide. 3) 1) 4) 19) Remove two screws and remove the toner motor. 2) 2) 15) Disengage the pawl, and remove the roller knob. 1) 16) Disengage the pawl, and shift the pulley and the bearing. 3) 2) 20) Remove three screws, and remove the DUP motor unit and the belt. (AR-M201) 1) 4) 17) Remove the paper exit roller, and remove the belt, the pulley, and the bearing.
21) Remove five screws and the grounding wire. For the AR-203E/5420/M200, remove the main drive plate and the belt. For the AR-M201, remove the main drive plate. 23) Remove four screws, and remove the paper guide unit. (AR-203E/5420) 1) 1) 1) 2) 2) 1) 1) 1) AR-203E/5420/M200 AL-2030 only 3) 1) 24) Remove four screws, and remove the lower paper guide unit.
25) Put the lower paper guide unit upside down, remove two screws, and remove the shifter motor. (AR-M200/M201) 30) Remove four screws, and remove the LSU unit. 1) 1) 1) 1) 2) 2) 26) Remove the screw, and remove the grounding plate and the gear. (AR-M200/M201) [Note for assembling the LSU] 27) Remove the E-ring, the gear, and the bearing, and remove the shifter roller.
31) Remove the screw, slide the left cabinet to the left to detach it. Remove each pawl, and remove the paper exit tray. 3) 34) Remove the screw and the E-ring, and remove the PS semi-circular earth plate and the PS roller unit. 35) Remove the E-ring and remove the spring clutch from the PS roller unit. 5) 4) PS roller unit Use grease of Floil FG40H only to apply to this section.
37) Remove the screw and the connector, and remove the PPD1 sensor PWB. 6. Manual paper feed section A. List No. 1 2 3 4 1) Part name Ref. Manual transport roller Cassette detection switch PPD1 sensor PWB Side door detection unit B. Disassembly procedure Multi unit 2) 1) Remove the screw and remove the multi upper cover. 1) 38) Remove two E-rings and remove the paper feed roller. 39) Remove three E-rings and remove the clutch unit.
2) Remove the screw and remove the side door detection unit. 4) Remove two screws and remove the multi feed bracket unit from the multi paper feed upper frame. 2) 2) 1) 1) Back 1) Wire treatment 2) 3) Remove three screws and remove the multi paper feed upper frame. 1) 1) 5) Remove three E-rings and remove the manual paper feed roller B9.
D. Pressure plate holder attachment 6) Remove the pick-up roller. 1) Attach the pressure plate holder so that the resin section is not covered with the seal M1-N. Seal M1-N 1) Pressure plate holder Attachment reference 2) 7) Cut the binding band and remove the multi paper feed solenoid. 1) Attachment reference 7. Rear frame section A. List Multi paper feed solenoid 3) 2) No. 1 2 3 4 Part name Ref. Scanner motor Main motor Exhaust fan motor Main PWB B.
2) Remove the connector. 3) Remove four screws, and remove the FAX PWB unit. (When the AR-FX13 is installed) 7) Remove two screws and one connector, and remove the exhaust fan motor. Note: Be careful of the installing directions of the fan. Attach it so that the blowing direction faces outside. 1) 2) 2) 3) 1) 3) 2) 2) 2) 4) Disconnect the connector. Blowing direction 5) Remove two screws, and remove the scanner motor. 8) Disconnect the connectors.
8 Power section 2) Remove the screw, and remove the DV cover. 1) A. List No. 1 Part name Ref. Power PWB 2) B. Disassembly procedure 1) Disconnect each connector. 2) Remove the screw, and remove the earth line. 3) Remove two screws, and remove the power PWB unit. 4) 1) 1) 1) 1) 3) Remove the used developer. 2) 1) 3) 5) 4) 4) Supply new developer. C. Assembly procedure For assembly, reverse the disassembly procedure. 9. DV unit section A.
C. DV blade E. DV sensor 1) Peel off the old DV blade. 1) Remove the Mylar. 2) Clean the attachment surface with alcohol. 2) Remove the screw, and remove the DV sensor. 3) Attach the new DV blade to the reference position. * Clean the sensor (A) section. A 1) B 0.5 DV blade IC A 2) 0 3) 2) DV-BOX AS B D. DV doctor A 1) Remove the screw, and remove the DV doctor. * Clean the edge (A) section. 10. Duplex motor section (AR-M201 only) A. List No. 1 1) A Part name Ref. Duplex motor B.
11. Reverse roller section (AR-M201 only) A. List No. 1 Part name Ref. Reverse roller B. Disassembly procedure 1) Remove four screws. 2) Remove the spring, and the earth wire. 3) Remove the reverse unit. 2 3 1 4) Bend the reverse roller and remove it. 1 C. Assembly procedure For assembly, reverse the disassembly procedure.
[9] ADJUSTMENTS 5) Calculate the main scanning direction magnification ratio. Main scanning direction magnification ratio 1. Optical section = A. Copy magnification ratio adjustment X 100 (%) (When a 100mm scale is used as the original.) Original (Scale) The copy magnification ratio must be adjusted in the main scanning direction and in the sub scanning direction. To adjust, use SIM 48-1.
c. Adjustment procedure B. Image position adjustment 1) Set the scale on the document table as shown below. (Use a long scale for precise adjustment.) There are following eleven kinds of image position adjustments, which are made by laser control except for the image scan start position adjustment. For the adjustments, SIM 50-01 and 50-10 are used. No.
(AR-M200/M201) To select the adjustment mode with SIM 50-01, use the [ key. ][ ] The relationship between the adjustment modes and the lighting lamps are as shown in the table below.
4) If the measurement value is out of the specified range, change the set value and repeat the adjustment procedure. The default value is 50. 2. Copy density adjustment Note: The rear edge void cannot be checked with the first sheet after entering the simulation mode, the first sheet after turning off/on the power, or the first sheet after inserting the cassette. Use the second or later sheet to check the rear edge void.
E. Copy density adjustment procedure Use SIM 46-1 to set the copy density for each copy mode. For selection of modes, use the [Exposure mode selector] key (or [ ][ ] key for the AR-M200/M201). (1) Test chart (UKOG-0162FCZZ) setting 1) Place the test chart so that its edge is aligned with the A4 (Letter) reference line on the document table. Then place a A4 (14" x 8 1/2") white paper on the test chart and close the document cover.
B. DV bias check Note: • A digital multi meter with internal resistance of 1GΩ must be use for correct check. • The adjustment volume is locked, and no adjustment can be made. 2) Set the test chart so that the scale is positioned as shown below, in the S-D mode and the D-S mode. Scale (S-D mode) Scale (D-S mode) Procedures 1) Set the digital multi meter range to DC500V.
2) Print start position (Duplex back surface) (SPF/RSPF) 50-19 (PHOTO) The size (length) of a document read from the SPF/RSPF is detected, the image at the trailing edge of the first printing surface is cut to make a void area. (The adjustment of void quantity at the time when the cassette paper size is not recognized.) The paper void quantity should be first adjusted before the image cut trailing edge void quantity (SPF/RSPF) is adjusted.
[10] SIMULATION, TROUBLE CODES 1. Entering the simulation mode Sim No. 02 Sub code 03 06 08 To enter the serviceman simulation mode, press the keys as follows: AR-203E/AR-5420 [Clear] key → Exposure mode selector key → [Clear] key → Exposure mode selector key AR-M200/AR-M201 [#] key → [∗] key → [Clear] key → [∗] key 09 03 05 To cancel the simulation mode, press the [Clear All] key. 06 2.
Sim No.
4. Descriptions of various simulations Main code 01 Sub code 01 Contents Details of function/operation Mirror scan operation [Function] When [OK]/[ENTER]/[START] key is pressed, the home position is checked and the mirror base performs full scan at the speed of the set magnification ratio. During operation, the set magnification ratio is displayed. The mirror home position sensor status is displayed with the "Drum replacement required lamp (or the copy mode indicator for the AR-M200/M201)".
Main code 02 Sub code 02 Contents Details of function/operation SPF/RSPF sensor status display (Only the AR-203E/ M200/M201 with the SPF/RSPF installed) [Function] The ON/OFF status of the SPF/RSPF sensors can be checked with the LCD/LED. When a sensor is ON, the sensor name is displayed on the LCD/LED.
Main code 05 Sub code 01 Contents Details of function/operation Operation panel display check [Function] When [OK]/[ENTER]/[START] key is pressed, all the LCD's on the operation panel are turned ON (all pixels ON). After 5sec of ON, the machine goes into the sub code entry standby mode.
Main code 06 Sub code 01 Contents Details of function/operation Paper feed solenoid ON [Function] When [OK]/[ENTER]/[START] key is pressed, the selected paper feed solenoid repeats ON for 500ms and OF for 500ms 20 times. When tray select key (or [Numeric] key or [ ][ ] key for the AR-M200/M201) is pressed, the paper feed solenoid setting is switched. Code number 0 1 2 Setting CPFS1 CPFS2 MPFS Remark Operation is possible only when No. 2 cassette is installed.
Main code 08 Sub code 01 Contents Details of function/operation Developing bias [Function] When [OK]/[ENTER]/[START] key is pressed, the developing bias signal is turned ON for 30sec. When, however, an actual output value is measured, use simulation 25-01. After completion of this process, the machine goes into the sub code entry standby mode. [Operation] (AR-M200/M201) 1) Initial display 08-01 DVLP BIAS SET. EXECUTING...
Main code 10 Sub code Contents Details of function/operation Toner motor aging [Function] When [OK]/[ENTER]/[START] key is pressed, the toner motor is rotated for 30sec. After completion of this process, the machine goes into the main code entry standby mode. [Operation] (AR-M200/M201) 1) Initial display 10-00 TONER MOTOR EXECUTING... 14 Cancel of troubles other than U2 [Function] Used to cancel troubles other than U2.
Main code 22 Sub code 01 Contents Details of function/operation Maintenance counter display [Function] When [OK]/[ENTER]/[START] key is pressed, the maintenance counter is displayed. [Operation] AR-M200/M201 AR-203E/5420 1) Initial display The operation is similar to simulation 20-01. 22-01 M-CNT ***,*** 02 Maintenance preset display [Function] When [OK]/[ENTER]/[START] key is pressed, the preset value (25,000 sheets, etc.) corresponding to the code set with simulation 21-01 is displayed.
Main code 22 Sub code 12 Contents Details of function/operation Drum counter display [Function] The drum counter is displayed. [Operation] AR-M200/M201 AR-203E/5420 1) Initial display The operation is similar to simulation 20-01. 22-12 DRUM CNT ***,*** 13 CRUM type display [Function] The CRUM type currently set (written) in the CRUM chip is displayed.
Main code 22 Sub code 18 Contents Details of function/operation Printer counter display [Function] The printer counter is displayed. [Operation] AR-M200/M201 AR-203E/5420 1) Initial display The operation is similar to simulation 20-01. 22-18 PRT.CNT ***,*** 19 Scanner mode counter display (AR-203E/M200/M201) [Function] The scanner mode counter is displayed. [Operation] AR-M200/M201 AR-203E 1) Initial display The operation is similar to simulation 20-01.
Main code 24 Sub code 06 Contents Details of function/operation Developer counter clear [Function] When [OK]/[ENTER]/[START] key is pressed, the developer counter value is cleared to 0, and "000,000" is displayed. [Operation] AR-M200/M201 AR-203E/5420 1) Initial display The operation is similar to simulation 20-01. 24-06 DVLP CLR.
Main code 24 Sub code 15 Contents Details of function/operation Scanner mode counter clear (AR-203E/M200/M201) [Function] When [OK]/[ENTER]/[START] key is pressed, the scanner mode counter value is cleared to 0, and "000,000" is displayed on the LCD/display. [Operation] AR-M200/M201 AR-203E 1) Initial display The operation is similar to simulation 20-01. 24-15 S-MODE CLR.
Main code 26 Sub code 04 Contents Details of function/operation Machine duplex setup [Function] When this simulation is executed, the current set duplex is displayed. Enter the code number corresponding to the desired duplex and press [OK]/[ENTER]/[START] key to save the setting. Code number 0 1 Duplex Duplex NO Duplex YES* Display item OFF ON * AR-203E/5420/M200: cannot be executed. 06 [Operation] The operation is similar to simulation 26-02.
Main code 26 Sub code 40 42 Contents Details of function/operation Polygon motor OFF time setup (Time required for turning OFF after completion of printing) [Function] When this simulation is executed, the current setting is displayed. Enter the code number corresponding to the desired setting and press [OK]/[ENTER]/[START] key to save the setting. Transfer ON timing control setup Code number Setting 0 1 2 3 0sec 30sec 60sec 90sec Display item AR-M200/M201 AR-203E/5420 0 SEC. 0 30 SEC.
Main code 26 Sub code 43 Contents Details of function/operation Side void setup [Function] When this simulation is executed, the currently set code of the side void quantity is displayed (initial display), and the set data are saved. (Setting range: 0 – 10, Default: 4 (= One side 2.0mm)) Code 0 1 2 3 4 5 Setting 0 mm 0.5 mm 1.0 mm 1.5 mm 2.0 mm 2.5 mm Remark Default Code 6 7 8 9 10 Setting 3.0 mm 3.5 mm 4.0 mm 4.5 mm 5.
Main code 41 Sub code 06 Contents Details of function/operation OC cover float detection level adjustment (Only the AR-203E/M200/M201 with the SPF/RSPF installed) [Function] When this simulation is executed, the current set value is displayed. When [OK]/[ENTER]/ [START] key is pressed, the mirror base unit moves to the SPF/RSPF scan position to acquire the OC cover float detection level. When the mirror base unit returns to the home position, the acquired value is displayed.
Main code 43 Sub code 04 Contents Details of function/operation Fusing temperature setting in multi copy [Function] For 20th sheet or later in multi copy, the fusing temperature is automatically changed from the temperature set with simulation 43-01 to the temperature set with this simulation. When this simulation is executed, the current set code number is displayed. Enter the code number and press [OK]/[ENTER]/[START] key to change the setting.
Main code 46 Sub code 01 Contents Details of function/operation Copy density adjustment (300dpi) [Function] Copy density is set for each mode. When this simulation is executed, the current se value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the copy becomes darker. When the set value is decreased, the copy becomes lighter. In this case, only Exp.3 copy is made.
Main code 46 Sub code 12 Contents Details of function/operation Density adjustment in the FAX mode (Collective adjustment) (Executable only when the FAX is installed.) [Function] When [START] key is pressed, scan is executed with the entered exposure adjustment value and the data stored on the FAX side is rewritten into the entered value. All data of the exposure adjustment values are rewritten into the same value.
Main code 46 Sub code 15 Contents Details of function/operation FAX mode density adjustment (Super fine) (Executable only when the FAX is installed.) [Function] When [START] key is pressed, scan is started with the entered exposure adjustment value and the data of the selected mode on the FAX side is changed to the entered value. For the density adjustment value table data, refer to simulation 46-13 (FAX mode density adjustment (Normal text).) [Operation] 1) Initial display ADJUST EXP.
Main code 46 Sub code 19 Contents Details of function/operation Exposure mode setup [Function] <γ table setting> When this simulation is executed, the code number of the current set gamma table is displayed. (Default: 2) Enter the code number corresponding to the desired gamma table, and press [Exposure mode selector] key (or [ ][ ] key for the AR-M200/M201) to change the mode and write into the EEPROM.
Main code 46 Sub code 29 Contents Details of function/operation Image contrast adjustment (600dpi) [Function] Contrast is set for each mode. When this simulation is executed, the current se value is displayed in 2 digits (Default: 50). Change the set value and press [START] key to make a copy under the set value. When the set value is increased, the contrast becomes higher. When the set value is decreased, the contrast becomes lower. In this case, only Exp.3 copy is made.
Main code 46 Sub code 32 Contents Details of function/operation Copier color reproduction setup [Function] Used to set color reproduction in each mode. Colors easy to be copied and colors difficult to be copied can be switched. Set value 0 1 2 Colors easy to be copied Purple, Blue, Red Water blue, Green, Blue Yellow, Red, Green Colors difficult to be copied Yellow, Green, Water blue Purple, Red, Yellow Blue, Water blue, Purple * This setting has virtually no effect on black-and-white documents.
Main code 48 Sub code 01 Contents Details of function/operation Front/rear (main scanning) direction and scan (sub scanning) direction magnification ratio adjustment [Function] Used to adjust the magnification ratio in the main scan (front/rear) direction and sub scan direction. Enter the adjustment value with [ ] [ ] key (or [Numeric] key for the AR-M200/M201). Press [START] key to save the set value and make a copy.
Main code 49 Sub code 01 Contents Details of function/operation Flash ROM program writing mode [Function] When this simulation is executed, "d" is displayed on the display (or "DOWNLOAD MODE" is displayed on the LCD for the AR-M200/M201), the machine goes into the program writing mode from PC to Flash ROM. Use the writing tool on the PC and write the program. During writing, the display shows as follows: After completion of download, turn OFF/ON the power to reset.
Main code 50 Sub code 01 Contents Details of function/operation Lead edge image position [Function] Used to adjust the copy image position and the lead edge void amount on copy paper. The adjustment is made by adjusting the image scan start position at 100% and the print start position (resist roller ON timing). When this simulation is executed, the current set value is displayed in 2 digits.
Main code 50 Sub code 06 Contents Details of function/operation Copy lead edge position adjustment (SPF/RSPF) (Only the AR-203E/M200/ M201 with the SPF/RSPF installed) [Function] Used to adjust the SPF/RSPF copy lead edge. When the adjustment value of the document scan position adjustment is increased by 1, the scan start timing is advanced by 0.1mm. The print result is shifted to the opposite direction of the scan start position.
Main code 50 Sub code 12 Contents Details of function/operation Document off-center adjustment [Function] Used to adjust document scan off-center adjustment. The adjustment modes can be selected by pressing [Exposure mode selector] key (or [ [ ] key for the AR-M200/M201). (Adjustment range: 1 – 99, Default: 50) ] When the adjustment value is increased, the print result is shifted to left.
Main code 50 Sub code 19 Contents Details of function/operation Duplex copy rear edge void adjustment (AR-M201 only) [Function] Used to adjust the rear edge void amount in duplex copy. When this simulation is executed, the current set value is displayed in 2 digits. (Center value: 50.) The adjustment modes can be selected by pressing [ ][ ] key. (Adjustment range; 1 – 99) Enter the adjustment value and press [START] key to save the set value and make a copy.
Main code 53 Sub code 08 Contents Details of function/operation SPF/RSPF scan position automatic adjustment (Only the AR-203E/M200/M201 with the SPF/RSPF installed) [Function] Place a A4 paper (white chart) so that it covers the SPF/RSPF scan glass and the OC glass together, and close the SPF/RSPF. When this simulation is executed, the current adjustment value is displayed as the initial display. * Default is 1. Adjustment range is 1 – 99. Adjustment unit 1 = about 0.
Main code 63 Sub code 02 Contents Details of function/operation Black level automatic correction [Function] Used to acquire the black level target value used for the black level adjustment of white balance. When this simulation is executed, the current correction value is displayed in 3 digits of 12bit hexadecimal number.
Main code 64 Sub code 01 Contents Details of function/operation Self print (1by2 mode) [Function] The status of the optical section is ignored and printing of one page is made. Also when the print command is received from the host, printing is made. When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since, however, the scanner is disabled, initializing is not made.
Main code 66 Sub code 03 Contents Details of function/operation FAX PWB memory check (Executable only when the FAX is installed.) [Function] Use to check the FAX PWB memory. [Operation] 1) Initial display SELECT CHECK MEMORY PRESS ←, → 2) [ ][ ] key or after 2sec Every time when [ → 2 → 3 → 1. When [ ] key is pressed, the second line is changed in the sequence of No. 1 ] key is pressed, the sequence is reversed.
Main code 66 Sub code 05 Contents Details of function/operation Signal send mode (Soft SW set value) (Executable only when the FAX is installed.) [Function] Use to set the signal send mode (Soft SW set value). Facsimile simulation design specifications.
Main code 66 Sub code 11 Contents Details of function/operation 300bps signal send (Max. value) (Executable only when the FAX is installed.) [Function] Use to set the 300bps signal send (Max. value). 1: NO SIGNAL 2: 11111 3: 11110 4: 00000 5: 010101 6: 00001 [Operation] 1) Initial display SELECT SIGNAL PRESS ←, → 2) [ ][ ] key or after 2sec Every time when [ ] key is pressed, the second line is changed in the sequence of No. 1 → 2 → 3 → 4 → 5 → 6 → 1.
Main code 66 Sub code 13 Contents Details of function/operation Dial test (Executable only when the FAX is installed.) [Function] Use to the dial test. [Operation] ■ Dial test (PULSE) ■ Dial test (DTMF) 1) Initial display 1) Initial display SELECT SIGNAL 1:PULSE 2:DTMF SELECT SIGNAL 1:PULSE 2:DTMF ∗ [Clear] key: FAX control is terminated. 2) Select 1 INPUT MAKE TIME (0-15) ∗ [Clear] key: FAX control is terminated. 2) Select 2 SELECT HIGH LEVEL 1:DEFAULT 2:SOFT SW.
Main code 66 Sub code 18 Contents Details of function/operation DTMF signal send (Soft SW set value) (Executable only when the FAX is installed.) [Function] Use to set the DTMF signal send (Soft SW set value). [Operation] 1) Initial display 3) Communication is started after setting the signal send level. INPUT DIAL # SENDING SIGNAL SSW PRESS CLEAR TO STOP ∗ [Clear] key: FAX control is terminated. ∗ [Clear] key: Returns to "1) Initial display".
Main code 66 Sub code 33 Contents Details of function/operation Signal detection check (Executable only when the FAX is installed.) [Function] Use to check the signal detection. [Operation] 1) Initial display CHECKING NONE PRESS CLEAR TO STOP When a signal is detected, the display is changed from NONE to the following. CI/CNG/CED/BT/DT/Flag/SDT/DTMF ∗ [Clear] key: FAX control is terminated. 34 Communication time measurement (Executable only when the FAX is installed.
Main code 66 Sub code 38 Contents Details of function/operation Time setting/check (Executable only when the FAX is installed.) [Function] Use to check the time setting. [Operation] 1) Initial display SELECT TO SET 1:DATE 2:TIME ∗ [Clear] key: FAX control is terminated. 2) Select 1 2) Select 2 xxxx.xx.xx(xxx) CHANGE? 1:YES 2:NO xx:xx CHANGE? 1:YES 2:NO "xxxx.xx.xx(xxx)" is the current value. (No revision of display) "xx:xx" is the current value.
Main Sub Details of trouble code code L3 00 Scanner return trouble L4 01 Main motor lock detection 32 Exhaust fan motor lock detection trouble L6 10 Polygon motor lock detection U1 03 FAX board battery error U2 04 EEPROM read/write error (Serial communication error) 11 Counter check sum error (EEPROM) 40 CRUM chip communication error B.
Main Sub Details of trouble code code F2 02 Content Toner supply abnormality Detail The maximum toner supply time is greatly exceeded. Cause CRUM chip trouble Improper developing unit Check Replace the CRUM chip. and Replace the developing unit. remedy 04 Content Improper cartridge (Destination error, life cycle error) Detail The destination of the main unit differs from that of the CRUM. When the life cycle information is other than Not Used (FFh).
Main Sub Details of trouble code code L1 00 Content Feeding is not completed within the specified time after starting feeding. (The scan head locking switch is locked) Detail The white area and the black marking on the shading plate are used to obtain the difference in the CCD level values for judgment of lock. When the difference in the levels of which and black is small, it is judged that the black mark could not be scanned by lock and the trouble code "L1" is displayed.
[11] MAINTENANCE 1. Maintenance table : Check (Clean, adjust, or replace when required.) Section Developing Process peripheral Parts Developer DV blade DV side seal (F/R) DV doctor Drum 25K 50K 75K : Clean 100K : Replace 125K : Adjust ✩: Lubricate Remark White streaks are made on the image. 2. Maintenance display system Toner Life Remaining quantity LED Machine Life LED Machine Developer 8K EMPTY NEAR EMPTY About 12.5% ON Operation allowed Flash Stop 25K ON at 25K of the developer count.
[12] USER PROGRAM The conditions of factory setting can be changed according to the use conditions. 3) To enter the toner save mode, press the light ( ) key. The light and dark indicator marked "1" will light up, indicating the toner save mode is selected. 1. Functions that can be set with user programs Toner save mode Reduces toner consumption by approximately 10%. Power save modes The unit has two power save modes of operation: preheat mode and auto power shut-off mode.
Program Mode No. 25 Copy effective paper width setting function (Bypass tray) 26 Copy effective paper width setting function (Tray) 28 Parameters *1 → Large (A4 width/ LETTER), 2 → Small (B5R width/INVOICE) *1 → Large (A4 width/ LETTER), 2 → Small (B5R width/INVOICE) *1 → ON, 2 → OFF Selection of copy start state (Polygon rotation on/ off) Fusing temperature 1 → Low, *2 → High setting when the bypass tray is used 29 3) Press the [ ] key [ ] or [ ting of the selected item.
A. Copy mode Program number Program name Setting codes (factory default setting appears in bold) Explanation 1 AUTO CLEAR 1: 10 SEC. 2: 30 SEC. 3: 60 SEC. 4: 90 SEC. 5: 120 SEC. 6: OFF • Auto clear time automatically returns the copy settings to the initial settings if no keys are pressed for a preset period of time following the end of a copy job. • This program is used to select the period of time. Auto clear time can also be disabled. 2 PREHEAT MODE 1: 30 SEC. 2: 1 MIN. 3: 5 MIN. 4: 30 MIN.
Setting codes (factory default setting appears in bold) Program number Program name 19 AE LEVEL ADJUST 1: SPF/RSPF (Adjustment to 5 levels is possible.) 2: DOCUMENT GLASS (Adjustment to 5 levels is possible.) • This is used to adjust the exposure level. • The automatic exposure level can be adjusted separately for the document glass and the RSPF. • For the procedure for adjusting the exposure and guidelines for numeric values. The factory default setting for the exposure level is center.
CCD Driver MCU-PWB 5V AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 1 12V Driver 24V A G C A5V USB I/F Sensor/SW PAPD,PPD3, PD2,CED2 Mechanical load CPFS2 MainMotor USB1T20 Scanner CLK(48MHz) 2nd Cassette (AR-203E Optional only) Fan Motor (2speed with Lock detect) C D S Printer CLK (18.3856MHz) R G B /MMD CCD (ILX558X) NF AFE(HT82V24) MMCLK USB2.
Fan Motor Shifter Motor Duplex Motor AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 2 Driver Driver A G C 18.3856MHz Printer CLK /MMD Sensor/SW PPD3, PD2, CED2 M P X /MMLD Main Motor Mechanical load CPFS2 Driver 24V 12V 2nd Cassette Duplex Model Only C D S SSCG Scanner CLK (12MHz x4 48MHz) MCU-PWB CCD Driver R G B A5V MMCLK 5V CCD (ILX558K) Reg AFE(HT86V26) 12V Mirror Motor Driver LSU LASER D[15…0] A[19…1] Reset IC 3.
24V P-GND /PMD PMRDY PMCLK_A AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 3 1 2 3 4 5 MPFS SOLENOID PPD1 CED1 D-GND CASSETTE PAPER SOLENOID RESIST ROLLER SOLENOID TONER MT CED1 LD - HSYNC D-GND +5V D-GND - LDEN - VIDEO - S/H D-GND 5 4 3 2 1 8 7 6 5 4 3 2 1 1 2 POLYGON MT MAIN MT INT24V PGND /MMD MMLD /MMCLK POD 1 2 3 4 5 DSW CN16 1 LEDPPD1 2 PPD1 3 D-GND B3B-PH-K-R DHAI-0289QSZZ CN15 1 24V 2 24V1(DSWS) B2P-VH-R CN26 24V /MPFS 5䌖 MFD DGND B5B-PH-K-R CN7 1 CED1 2 D-GND 3 D-GND B3B-P
1 2 3 4 5 AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 4 MPFS SOLENOID PPD1 CED1 PD1 CED1 D-GND CASSETTE PAPER SOLENOID RESIST ROLLER SOLENOID TONER MT MAIN MT INT24V PGND /MMD MMLD /MMCLK 5 4 3 2 1 1 2 POLYGON MT 24V P-GND /PMD PMRDY PMCLK_A LD 8 7 6 5 4 3 2 1 DHAI-0519QSPZ - HSYNC D-GND +5V D-GND - LDEN - VIDEO - S/H D-GND FAX Model only POD Duplex Model only DUPLEX MT SHIFTER MT Fan MT Thermistor PPD2 D-GND LEDPPD2 PPD2 D-GND CN27 24VSFTMT /SFTMT_0 /SFTMT_1 /SFTMT_2 /SFTMT_
C. SPF unit (AR-203E optional only) MCU PWB CN24 24VSPFMT 24VSPFMT SPMT_0 SPMT_2 SPMT_1 SPMT_3 SPID DGND LEDSPID SPPD DGND LEDSPPD B12B-PH-K-S DHAI-0532QSP1 1 2 3 4 5 6 7 8 9 10 11 12 5 2 4 6 3 1 COMA COMB A /A B /B 1 2 3 SPID DGND LEDSPID SPID 1 2 3 SPPD DGND LEDSPPD SPPD SPMT SPF UNIT D.
F.
Signal name /RD /RRS /RSV_SOL /SFTMT0 /SFTMT1 /SFTMT2 /SFTMT3 /SPUS /SRVC /SYNC /TC /VFMCNT /VIDEO BZR CCD_PHI1 CCD_PHI2 CCD-CP CCD-RS CCD-TG CED1 CED2 DVSEL FANLK FW HLOUT KEYIN KEYSC1 KEYSC2 KEYSC3 LCDCON LCDDB4 LCDDB5 LCDDB6 LCDDB7 LCDE LCDRS LEDPOD LEDPPD1 LEDPPD2 LEDSCOD LEDSPID LEDSPID LEDSPPD LEDSPPD LEDSRJD MCU_D0 MCU_D1 MCU_D2 MCU_D3 MCU_D4 MCU_D5 MCU_D6 MCU_D7 MCU_INT MCU_NCS MHPS MMLD MODEM_IN ONL OP_CLK OP-DATA OP-LATCH OUTAOUTA+ Name Control signal 1st transport solenoid Reverse solenoid Shift
Signal name OUTBOUTB+ PB_ADDR0 PB_ADDR1 PB_ADDR2 PB_ADDR3 PB_ADDR4 PB_ADDR5 PB_ADDR6 PB_ADDR7 PB_DATA0 PB_DATA1 PB_DATA2 PB_DATA3 PB_DATA4 PB_DATA5 PB_DATA6 PB_DATA7 PB_NAE0 PB_NCS1 PB_NOE PB_NWE PD1 PD2 PMCLK_A PMRDY POD PPD1 PPD2 PPD3 PSL PSW RTH_IN SCOD SELIN1 SELIN2 SELIN3 SHOLD SPID SPID SPMT_0 SPMT_0 SPMT_1 SPMT_1 SPMT_2 SPMT_2 SPMT_3 SPMT_3 SPPD SPPD SRJD STROBE TCS TMA_O TMA_O TMB_O TMB_O USB +D USB -D VCL VFMOUT Name Scanner motor Scanner motor Address signal Address signal Address signal Address
A B C 0J 680J OPEN OPEN OPEN 15pF 15pF 0J 27pF 27pF R3(*2) C5(*5) C1(*6) CPU3.3 5 (2) /CS2 (3) /CS1 (3) /CS0 (8) PSL (2) /SCANSP (2) /SCANST (2) /TRANSST (5) PMCLK (4) SPFMT3 (4) SPFMT2/MIRCNT (4) SPFMT1 (4) SPFMT0 *R3,R4,C1, and C5 are temtative OPEN 22J R8(*4) 0J R6 TP255 N.M.
A B C 33J 8 10kJx4 8 RAMDB11 7 RAMDB10 6 RAMDB9 5 RAMDB8 BR48 1 2 3 4 L10 VCC3 TP449 10kJx4 8 7 6 5 BR45 1 2 3 4 0J (1608) C74 N.M. R47 N.C. VCC X2 GND OUTPUT 1000p N.C. VCC X3 GND OUTPUT 5 SG8002DC(18.3856MHz) CLK_CONT1 8 SG8002DC(48.0000MHz) C76 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 11 A B C (1,2) D[15..0] (1,2) A[20..0] 5 (1) /CS1 (1,2) /RD (1) /HWR /RD /HWR (1) SCL (1) SDA A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 N.M. C235 D 5 28 12 1 2 3 4 13 14 15 16 17 18 19 20 21 29 30 31 32 1kJ GND GND VDD VDD I/O0 I/O1 I/O2 I/O3 I/O4 I/O5 I/O6 I/O7 C81 0.1u 9 25 8 24 6 7 10 11 22 23 26 27 8 7 6 5 VCC WC SCL SDA IC5 E0 E1 E2 VSS 1 2 3 4 0.1u C83 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 12 A B C D 5 (7) (PD1) (7) (PD2) (7) (SPID) (7) (FANLK) (7) (PPD2) (7) (PPD3) (5) THOPEN (7) (CED2) (7) DSWS (7) (MMLD) (8) (SELIN1) (8) (SELIN2) (8) (SELIN3) (7) (PPD1) (7) (POD) (7) (MFD) (7) (CED1) (7) (TCS) (7) (PMRDY) (7) DVS1 (7) (DRST) TP482 TP483 TP480 4 3 2 1 15 14 13 12 TP471 TP472 TP473 TP474 TP475 TP476 TP477 TP478 11 10 9 7 4 3 2 1 15 14 13 12 11 10 9 7 11 10 9 7 4 3 2 1 15 14 13 12 TP484 TP485 TP486 TP463 TP464 TP465 TP466 TP
A B C D (1) MMCLK (2) VFM_24V (2) VFMCNT_12V 5 6 7 8 R142 10kJ(open) R414 N.M._10kJ VCC3 Q14 5 KRC102S 2 R418 N.M._10kJ VCC3 1.5kJx4 8 7 6 5 R370 1.5kJ BR56 1 2 3 4 R138 10kJ 4 3 2 1 R419 N.M.
A B C D 4 5 (SPFMT0) (SPFMT2) (SPFMT1) (SPFMT3) (5) MRPS_1 (5) MRPS_2 (5) MRPS_3 (4) (4) (4) (4) (5) MMref0 (5) MMref1 (5) MMref2 (9) OUT_A(9) OUT_A+ (9) OUT_B+ (9) OUT_B- R125 2kJ TP595 TP596 TP597 R134 300J TP588 TP589 TP590 R126 1kJ R135 620J R136 1.2kJ 10kJx4 BR59 R127 510J 0.1u PGND C131 R131 1.2kJ PGND 5V PGND C118 820p TP587 (2) MM_BI0 (2) MM_BI1 (2) MM_PH_B TP586 R121 1.5kJ PGND C120 0.1u R137 100J 5V C117 820p R122 1kJ PGND 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 15 A B C D C145 N.M. C152 0.1u C144 N.M. C151 0.1u (8) 12VIN N.M. 0.1u 1 0J (1608) 47u/35V 5 22u/16V C181 47u/25V C177 L4 ZJSR5101-223(open) L14 1000p 1000p C169 C224 C223 TP14 0.1u + 1 1000p C225 TP15 R242 10J 0.1u C156 0.1u C149 N.M. C140 + + PGND C155 N.M. C148 N.M. C139 TP13 1 0.1u C154 N.M. C147 0.1u C138 R241 10J 0.1u C153 N.M. C146 0.1u C137 R240 10J VCC3 C136 C135 0.1u C183 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 16 A B C D EN5V 5V (7) 12VIN (4) FW (5) /PR (5) /BIAS (5) /GRIDL 5 INT5V PGND INT24V PGND R400 N.M._1608size PGND 2 4 6 8 10 12 14 16 18 20 22 24 B24B-PNDZS-1 1 3 5 7 9 11 13 15 17 19 21 23 CN1 To Power unit 4 HLOUT (5) /POFF (5) 24V 3.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 17 A B C PGND 24V 5 (White) B2P-VH 1 2 CN23 24V PGND PGND R206 PGND 1kJ (Red) B2P-VH-R 1 2 CN15 (White) B4B-PH-K-S 1 2 3 4 CN11 B5B-PASK-1 1 2 3 4 5 CN6 3 KDS226 D42 2 1 5V INT5V B08B-CZHK-B 1 2 3 4 5 6 7 8 CN42 To Interlock switch To Fan motor To Main motor To Polygon motor (5) /LDEN (4) /VIDEO (5) SHOLD B05B-CZHK-B 1 2 3 4 5 1000p 1000p (4) /SYNC C201 C200 CN41 1000p 1000p To Toner motor (6) TMA_O (6) TMB_O
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 18 4 0.1u/50V C209 R210 15kJ VCL 3 (4) mt_at_home R213 1kJ 1000p C211 R211 12kJ VCC3 2 1 KDS226 D43 3 (4) AFE_DB#[7..0] (4) AFE_SCK# (4) ADCLK# (4) CCD_PHI1# (4) CCD_PHI2# (4) CCD_CP# (4) CCD_RS# (4) CCD_TG# CP9 2 VCL AFE_DB#0 AFE_DB#2 AFE_DB#4 AFE_DB#6 PGND 0603FA1.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 19 A B C D 4 5 (2) SUSPEND (2) RCV (2) VPIN (2) VMIN (2) VPOUT (2) VMOUT (2) OEN (4) (D_CONT) (4) USB_IN N.M. N.M. N.M. C216 C217 C215 R221 R223 R224 33J 33J 33J 4 TP563 TP564 TP565 VCC3 6 3 4 5 2 9 12 13 VCC GND NC D+ D- MODE USB1T20 SUSPEND RCV VP VM OE# SPEED VPO VMO/FSEO IC31 7 8 TP566 0.1u C214 R219 1 TP567 11 10 R420 14 VCC3 MCU PWB (USB2.0 (FULL) I/F section) (AR-203E only) 5 TP568 TP569 N.M. N.M.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 20 A B C D 4 (1) CRUMSCL (1,2,4) /ASIC_RST (1) CRUMSDTA 5 R231 0J 3.3V 3.3V TP572 R139 1kJ 4 1 0.1u C220 R232 10kJ(open) R225 N.M. VCC3 GND B Vcc 3 2 5 N.M. 2 3 5 1 EN5V 4 5V C218 0.1u EN5V NC7ST08M5X(open) IC34 TC7SBD385AFU(open) OE A IC32 R376 4 TP574 TP573 R226 10kJ (CRUMSCL) (CRUMSDTA) 5V MCU PWB (CRUM I/F section) (AR-203E/5420) 5 (5) TCS_AN (7) TCS (7) DVSEL TP575 TP576 R368 R369 3 N.M.
1 2 (6) CPU3.3 LCDCONT 33J (8) (9) TP109 (3) (2) (4) (4) A C11 NM TP724 33P R25 5 6 7 8 C9 33P C19 10U/10V<2012> L1 NM_ZJSR5101-223TA FB1 0J <1608> SPFMT3 SPFMT2 SPFMT1 SPFMT0 /RES_USB20 /SCANSP /SCANST /TRANSST /ES_PAGE PROTECT /RES_OA982 /RES_IOASIC /RES_GASIC (PSFANLK) /ES_PAGE /CSIOASIC /CSGASIC /CSSRAM /CSFROM (2) /SCANSP (2) /SCANST (2) /TRANSST (6) PMCLK (5) SPFMT3 (5) SPFMT2/MIRCNT (5) SPFMT1 (5) SPFMT0 (10) /RES_USB20 R51 RTH (TCS_AN) 0.
VCC3 1 (4) 2 3 4 CCD_CP AFE_SEN ADCLK AFE_SCK (5) (5) (5) (5) 10KJX4 8 RAMDB11 7 RAMDB10 6 RAMDB9 5 RAMDB8 BR53 1 2 3 4 PFCLKIN PFCLKOUT TP720 R68 R70 10KJX4 8 RAMDB15 7 RAMDB14 6 RAMDB13 5 RAMDB12 BR49 1 2 3 4 TP719 10KJX4 8 RAMDB3 7 RAMDB2 6 RAMDB1 5 RAMDB0 BR45 1 2 3 4 SDCLK 10KJX4 8 RAMDB7 7 RAMDB6 6 RAMDB5 5 RAMDB4 RAMDB[15..0] MAD[12..
1 2 3 4 A (2,5) (/ASIC_RST) (1) /RES_IOASIC R135 33J R136 NM 1000P C98 A[20..0] B (1,2,4,13) D[15..0] (1,2,4) A4 A3 A2 A1 A0 (1) D13 D12 D11 D15 D14 CPUCLK# /RD /HWR /CSIOASIC (1,2,4,5) (1,4) (1) (11) KEYIN TP635 TP294 TP296 TP285 TP287 TP282 IC52 (11) (11) (11) IOIC3.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 24 1 2 3 R76 (1) /CSSRAM (1,2,3,5) /RD (1,3) /HWR A[20..0] (1,2,3,13) D[15..0] (1,2,3) (1) SCL (1) SDA A A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 TP726 100J NM C352 4 B 5 28 12 1 2 3 4 13 14 15 16 17 18 19 20 21 29 30 31 32 GND GND VDD VDD 9 25 8 24 6 7 10 11 22 23 26 27 VCC3 I/O0 I/O1 I/O2 I/O3 I/O4 I/O5 I/O6 I/O7 C82 0.
1 2 3 4 C16 (2,3) (/ASIC_RST) (1) R64 RESETOUT1 1U<2012> 0.1U C290 33J 1 2 CT 3 4 33J A C79 47P TP395 R345 1KJ OP Reset R28 ASIC Reset BU4212F GND VDD VOUT IC3 Reset Circuit R29 10KJ VCC3 C26 47P C18 NM /OP_RST TP386 0.
1 2 3 PR MM_Y1 MM_Y2 MM_Y3 PMD PMCLK LDEN /LEND R116 10KJ (1) MMCLK 100J R339 (2) VFM_24V (2) VFMCNT_12V TP474 TP797 TP799 TP798 100J 10KJ R268 PR# 16 15 14 13 12 11 10 9 A TP475 1C 2C 3C 4C 5C 6C 7C NC (2) (2) (2) (2) Q21 TP464 TP805 TP806 TP807 KRC102S 2 KRC102S 2 TP723 TP722 Q14 10KJ R269 R418 NM_10KJ KID65503F 1B 2B 3B 4B 5B 6B 7B G R304 1 2 3 4 5 6 7 8 IC27 R142 NM_10KJ R414 NM_10KJ VCC3 R419 NM_10KJ VCC3 TP792 TP785 TP790 TP789 10KJ R265 10KJ R271 10KJ
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 27 1 2 3 4 (12) (12) (12) (12) (TM) (TM_) (5) MRPS_1 MRPS_2 MRPS_3 (SPFMT0) (SPFMT2) (SPFMT1) (SPFMT3) MMref0 MMref1 MMref2 OUT_AOUT_A+ OUT_B+ OUT_B- (5) (6) (6) (6) (5) (5) (5) (5) (6) (6) (6) B R160 300J R150 2KJ A R161 620J R162 1.2KJ PGND C144 NM_10U/10V<2012> PGND 1 2 3 4 5 6 7 8 9 10 11 12 5V TP478 VS SENSE 1 COMP 1 OUT 1B I01 GND GND I11 PHASE 1 VREF 1 RC 1 VSS PGND C138 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 28 1 2 3 NM C156 NM C163 0.1U C155 NM C162 0.1U (11) C181 1000P C180 1000P 12VIN TP510 TP509 0.1U C165 NM C158 0.1U C149 A 1000P C182 TP511 R194 10J 0.1U C166 NM C159 NM C150 47U/35V C190 22U/16V C204 47U/25V C194 + 0.1U C168 0.1U C161 NM C152 + + PGND 1000P C183 TP512 R195 10J 0.1U C167 0.1U C160 NM C151 L4 NM_ZJSR5101-223TA FB4 0J <1608> R193 10J 0.1U C164 NM C157 0.
1 2 R239 VCC3 R240 R241 R242 R243 R244 TDO TCK TMS TDI TRST_L R137 33J R138 NM 10KJ 10KJ 10KJ 10KJ 10KJ NM_10KJ (2,4,5,12) /RESET0 (1) /RES_OA982 (5,10) /OP_RST (2) PODATA[7..0] /FPOFF C216 NM A R342 R343 C100 1000P (12) PODATA7 PODATA6 PODATA5 PODATA4 PODATA3 PODATA2 PODATA1 PODATA0 10KJ R238 (10,13) PB_ADDR[7:0] /ES_PAGE /ES_CRDY /ES_SRDY WAKEUP (1) (3) (1) (10) (2) (2) (2) (2) (10) (2) (2) C254 33P R247 R248 (12) (12) (12) (12) TRST_L VCC3 R245 R246 X4 AT-49(18.
1 2 3 4 (9) PB_NAE0 DT_ACKB (5,9) L7 C410 0.1U BLM21PG600SN1 A TP880 5 4 3 2 1 3 2 5 VCC3 IC183 TC7SH126FU 4 USB2.0 DEV1 SHIELD GND +D -D +5V CN1 UBR23-4K2200 FG 100KJ R399 (9) C274 0.01U DLW21SN900SQ2 TP908 VCC3 BLM21PG600SN1 L9 L8 R111 1MF C271 0.1U PB_NCS3 R267 NM_<1608> C404 1U<2012> TP907 GND C270 0.1U VCC3 C409 0.1U C408 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 31 1 2 3 To LD A (6) (5) (6) /LDEN /VIDEO SHOLD /SYNC SPPD (8) (5) SPMT_0 SPMT_2 SPMT_1 SPMT_3 SPID (7) (7) (7) (7) (8) (8) (5) (6) 5V C275 0.
1 2 3 (6) (8) (6) (6) (8) (6) TMA_O TMB_O /SFTMT0 /SFTMT1 /SFTMT2 /SFTMT3 (7) (7) (7) (7) OUT_A+ OUT_B+ OUT_AOUT_B- (7) (7) (7) (7) A 1000P To Duplex motor (White) To Mirror motor 24VSFTMT To Toner motor To Shifter motor (White) B5B-PH-K-S(LF)(SN) 1 2 3 4 5 CN27 (White) B2P-VH(LF)(SN) 1 2 CN25 (Red) To VF Fan motor B4B-PH-K-S(LF)(SN) 1 2 3 4 CN16 (White) B4B-PH-K-R(LF)(SN) 1 2 3 4 To Main motor B5B-PASK-1(LF)(SN) B05B-XASK-1(LF)(SN) 1 2 3 4 5 CN20 PGND PGND CN22 24V
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 33 1 2 3 (1) A /CS5 TP725 100J R391 NM C378 (3) (5) /FAX_RST MSU_ST1 (1) /RES_FAX (9) B MDM_IRQ R313 100J R325 NM 2 1 KDS226 D47 2 1 VCC3 R311 1KJ 3 PB_ADDR7 PB_ADDR6 PB_ADDR5 PB_ADDR4 PB_ADDR3 PB_ADDR2 PB_ADDR1 PB_ADDR0 D7 D6 D5 D4 D3 D2 D1 D0 MSU_ST1 D[15..
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 34 1 2 3 (2) CL A 33P R323 15KJ C341 R324 56KJ C338 47U/35V 24V + R318 910J 1 3 Q5 2SJ537 PGND Q6 KTC3198 CP18 0603SFF150FM/32-2 2 B D49 11EQS06 TWKA-221K L12 220UH 47U/35V + C339 Copy Lamp Inverter R321 4 B R319 15KJ 0.1U/50V<1608> C340 MCU PWB (Scanner I/F section) (AR-M200/M201) A 5.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 35 B C (2) (2) (2) (2) (2) (2) (2) (2) (2) (2) /ACK_O BUSY_O PE_O SLCT_O /FAULT_O /STB_I /AUTOFD_I /SLCTIN_I /INIT_I /REV_O 1 2 3 4 1 2 3 4 /ACK_O BUSY_O PE_O SLCT_O /FAULT_O /STB_I /AUTOFD_I /SLCTIN_I /INIT_I /REV_O R402 NM 8 7 6 5 8 BR94 33JX4 7 6 5 BR95 33JX4 L19 0J <1608> TP906 EN5V D 24FMN-BTK-A 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CN39 C346 0.1U C345 0.1U VCC3 To NIC PWB 0.1U C343 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 36 1 2 3 4 (1) A CRUMSCL /ASIC_RST (1) CRUMSDA (5) B R337 3.3V 0J 3.3V TP883 4 1 GND B Vcc 3 2 5 2 3 5 1 4 TC7SET08F IC51 FB8 EN5V TC7SBD385AFU OE A IC49 FB9 0J or CHIP INDUCTER(NM) <1608> R335 10KJ TP887 TP884 B F-GND 2 F-GND 1 5V C348 0.1U EN5V 0J or CHIP INDUCTER(NM) <1608> 0.
1 2 CN304 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 D-GND DRST 5V KIN2 PSW ONL PSL D-GND 5VEN OP-DATA OP-LATCH SELIN2 OP-CLK SELIN1 OP-STB SELIN3 KIN1 D-GND A 18FMN-BMTTR-A-TB or IMSA-9619S-18C-TB D-GND DRST S3B-PH-K-S 1 2 3 CN303 +5V 2 D-GND DRST 5V PSW KIN2 KIN1 OP-STB OP-CLK OP-LATCH OP-DATA SELIN1 SELIN2 SELIN3 D-GND 5VEN PSL ONL D-GND TP1 1 1 22000PF TP49 TP50 N.M.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 38 1 2 3 OP-LATCH OP-DATA OP-CLK A Open C308 2 KRC106S Q302 1 3.3V R324 0J 1 3 R323 10KJ 2 3 Q303 KRA225S 2 3.3V 2 3 TP1 R326 0J Q305 KRA225S R304 100J R302 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 39 1 2 SELIN3 SELIN2 SELIN1 5V KEYSC1 KEYSC2 KEYSC3 Open Open A C310 C311 Open C309 47pF C315 Open Open Open KEYIN C320 C319 BZR C318 2kJ R346 3 2kJ R347 4 B 0.1u PSW 5V 0.
AR-203E/5420/M200/M201 ELECTRICAL SECTION 13 - 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 A OP-LATCH PSL PSW OP-DATA OP-CLK B C302 47uF/16v LCDDB[7..4] 0.1u C325 C301 47uF/16v 0.
[14] FIRMWARE DOWNLOAD PROCEDURES 2) Select "Option" → "Serial Number Setting" on the menu bar. 3) Set the serial number according to the following. [Preparation] Write the download data (extension .dwl) into the main unit. A USB port is required for the PC. Create "MaintenanceTool" flooder in the PC, and copy the following files to the folder. Necessary for program download • Maintenance.exe (← Tool program) • ProcModelQ.fmt • ProcModelQ.mdl Driver • Drivers/Vista/Mainte.
4) PC side: Check that the "Simulation Command List" tree is displayed on the integration maintenance program. 5) PC side: When the integration maintenance program is boosted and "The copier is not turned on." is displayed at the bottom of display, select "File" → "Reconnect" on the menu bar. 6) 8) PC side: Specify the download file (*****.dwl) to be used. 9) PC side: When a download file is specified, downloading is performed automatically.
Note: When another machine is connected, connect the USB cable again and select "File" → "Reconnect" on the menu bar of the integration maintenance program. Repeat the above procedures from 5). 4) PC side: Check that the "Simulation Command List" tree on the integration maintenance program. 5) PC side: Boot the integration maintenance program. If "The copier is not turned on." is displayed, select "File" → "Reconnect" on the menu bar.
7) PC side: Double-click "Special (MCU/IMC2/Facsimile)" in the main tree items to develop its sub trees. Select "Get Version" in the sub trees. 8) Check that the following display is shown. 4) PC side: Check that "Simulation Command List" tree is displayed in the integration maintenance program. 5) PC side: Boot the integration maintenance program. If "The copier is not turned on." is displayed on the lower side of the display, select "File" → "Reconnect" on the menu bar.
7) PC side: Double-click "Special (MCU/IMC2/Facsimile)" to develop its sub trees, and select "Upload EEPROM Data Area" in the sub trees. 5. Installing procedures Driver installation is made on plug-and-play. 1) Main unit side: Execute simulation No. 49-01 (Flash ROM program write mode). Check that "d" is displayed (or "DOWNLOAD MODE" is displayed for the AR-M200/M201) on the operation panel.
5) When the following display is shown, select [Browse my computer for driver software (advanced)]. 8) The path to the folder which includes the maintenance tool driver (Maintenance.inf) is displayed. Press [Next] button. 6) The following display is shown. 9) When the following display is shown, select [Install this driver software anyway]. 10) When the following display is shown, close [Close] button to complete installation.
1) 5) Main unit side: Execute simulation No. 49-01 (Flash ROM program write mode). (Suppose that the driver is included in C:\MaintenanceTool\Drivers\2kXp folder.) Check that "d" is displayed (or "DOWNLOAD MODE" is displayed for the AR-M200/M201) on the operation panel. (Press and hold [Clear] key and [ZOOM DOWN] key ( ) (or [ZOOM]/[COPY RATIO] key for the AR-M200/M201) together, and turn on the power simultaneously.) 2) Connect the machine and the PC with a USB cable.
8) When the following display is shown, installation is completed. 5) Select [Specify a location] and press button. 6) Select [Include this location in the search;]. If the search location is not the folder which includes the maintenance tool driver (Mainte.inf), select . If the search location is the folder which includes the maintenance tool driver, press button to go to procedure 9). 7) Specify the folder which includes the maintenance tool driver (Mainte.
8) Check that the path to the folder which includes the maintenance tool driver (Mainte.inf) is displayed, and press button. 1) (Suppose that the maintenance tool driver is included in C:\MaintenanceTool\Drivers\2kXp folder.) Main unit side: Execute simulation No. 49-01 (Flash ROM program write mode). Check that "d" is displayed (or "DOWNLOAD MODE" is displayed for the AR-M200/M201) on the operation panel.
5) Select the folder which includes maintenance tool driver (Mainte.inf), and press button. (Suppose that the driver is included in C:\MaintenanceTool\Drivers\Win9xMe folder.) 6) Check that the path to the folder which includes the maintenance tool driver (Mainte.inf) is displayed, and press button. 7) When the following display is shown, installation is completed. Press button. 8) Restart the PC.
Memo
Memo
LEAD-FREE SOLDER The PWB’s of this model employs lead-free solder. The “LF” marks indicated on the PWB’s and the Service Manual mean “Lead-Free” solder. The alphabet following the LF mark shows the kind of lead-free solder. Example: Lead-Free 5mm Solder composition code (Refer to the table at the right.
CAUTION FOR BATTERY REPLACEMENT (Danish) ADVARSEL ! Lithiumbatteri – Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandoren. (English) Caution ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to manufacturer’s instructions.
COPYRIGHT © 2008 BY SHARP CORPORATION All rights reserved. Printed in Japan. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic; mechanical; photocopying; recording or otherwise without prior written permission of the publisher.