Installation Instructions

Table Of Contents
3. Connect output terminal
A. Connect device as per the type of load.
B. Connect L1 and L2 to the device
. (Fig.5)
Indicator
Indicator
Button
Expand
Interface
Input
Terminal 1
Input
Terminal 2
Neutral Terminal
Patch Point
(live line)
Patch Point
(relay input)
Output Terminal 1
Output Terminal 2
Live Terminal
The Terncy Switch Module (Model: TERNCY-SM01-D2/
TERNCY-SM01-D3), is an easy to install accessory. By
installing it into switches, sockets or other electrical
devices, you can create a remote connection for smart
lighting, use voice control, create automations, or other
functions via Home center.
1. Connect L and N line
Connect L line to L, N line to N
. (Fig.1)
2. Connect input terminal
Connect two routes of lines to S1 and S2 respectively.
A.C. device: Connect L and IN with the
attached wire. (Fig.3)
D.C. device: Connect D.C. power line directly
to IN. (Fig.4)
For D.C. device, do not link L with IN.
A. Connect an LED indicator.
This can drive the LED indicators on switches or
supply power to external devices.
Unclench the cover of the interface. (Fig.6)
Insert the 6-pin header into the interface rmly
. (Fig.7)
Connect the +/- wire of LED1 or LED2 to the plus-n-minus
of the LED indicator
. (Fig.8)
Do not touch the expand interface whilst the power is on.
The Module supports up to two sets of 5V or 12V LED
indicator with 20mA max output current.
Switch Module follows ZigBee 3.0 wireless protocol.
It needs to be connected to N and L line at the same time.
Power o during installation to prevent electric shock.
N line
L line
N line
L line
D.C.
Power
Download the Terncy app from app markets or scan the
QR code below. Follow the instructions within the app
to connect the Switch Module to Home Center.
Click the "Add Device" button in the Device tab
of the Terncy app.
The new device can be found after 3 seconds
under power-on conditions.
1.
2.
Switch Module Introduction
Guidance
Guidance Guidance Guidance Indicator Light State Download and Install App Setting Up The Accessory for The First Time
Device
Add Device
3012
Add Device
Scanning
new devices
3012
Add Device
Add
Scanning
new devices
2798-01
连接其他设备
取消
Home
Add Home Center
Add End Point
Accessory
Terncy Switch Module
Model:TERNCY-SM01
Shanghai Xiaoyan Co.,Ltd
Fig.1 Fig.2 Fig.3
Fig.6 Fig.7 Fig.8
Fig.9
Fig.4
Fig.5
3
4. Connect to the expand interface
Connect 12V and GND of the 6-pin header to the
corresponding plus-n-minus of external device. (Fig.9)
The Module supports 12V d.c. with 50mA max
output current.
B. Supply power for external devices.
Indicator
State
Green light ashes
10 times per sec.
Green light always on
Green light ashes
every 2 sec.
Green light ashes
4 times per sec.
Connecting to Home
Center nearby
Powered on
Successfully connected
to Home Center
Failed to connect to
Home Center
(Fig.2)