A8000 User Guide Confidential Document Name: A8000 User Guide Version: 1.0 Date: May 13th, 2009 DocId: A8000_User_Guide_V1.0 Status: Confidential / Released LONGSUNG GSM MUDLE A8000 user guide describes interfaces, function and application, which is provided to LONGSUNG’s customers for testing, evaluation, integration and information. LONGSUNG reserves the right to make changes without further notice to any products herein.
A8000 User Guide Confidential VERSION HISTORY Version V1.0 Author Liu Zhongrong A8000_User_Guide_V1.
A8000 User Guide Confidential CAUTION: A8000 module is an ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 1 K Volts readily accumulate on the human body and test equipment and can discharge without detection. Permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance degradation or loss of functionality. A8000_User_Guide_V1.
A8000 User Guide Confidential Contents 1.Introduction ................................................................................................................................5 1.1 Overview............................................................................................................................................... 5 1.2 A8000 Key Features........................................................................................................................... 5 1.3 Operating Modes .
A8000 User Guide Confidential 1.Introduction 1.1 Overview LONGSUNG A8000 is a dual band GSM/GPRS module that works on 850MHz/1900MHz. Powered by Infineon PMB7880 chipset, A8000 features GPRS multi-slot class 10 and supports the GPRS coding schemes CS-1, CS-2, CS-3 and CS-4. With power saving technique, A8000 can minimize current consumption to as low as 5.5mA in SLEEP mode, and is able to wake up on demand and to resume power saving automatically if no activity is required.
A8000 User Guide Confidential External antenna Connected via 50 Ohm antenna connector or antenna pad Audio features Speech codec modes: • Half Rate (ETS 06.20) • Full Rate (ETS 06.10) • Enhanced Full Rate (ETS 06.50 / 06.60 / 06.80) • Echo suppression Serial interface •seven lines on serial port Interface; •software download; •print debug information. Phonebook management Supported phonebook types: SM, FD, LD, RC, ON, MC. SIM Application Toolkit Supports SAT class 3, GSM 11.
A8000 User Guide Confidential GPRS DATA SWITCH OFF GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink/downlink data rates and GPRS configuration (e.g. used multi-slot settings). Normal shutdown by using the SWITCH_ON. In this case only the power supply for the RTC is remained. Software is not active. So the application interfaces cannot work. Operating voltage (connected to VBAT) remains applied. 2.
A8000 User Guide Confidential RESET_N GND 42 1,2,4,5,20 ,21,49,59, 60 I - A8000 system reset Ground Logic LOW effective - 2.1.2 Turn On / Off A8000 2.1.2.1 Turn On A8000 To turn on A8000, the following procedures may be used: • As default settings, A8000 will be turning on automatically when detecting voltage applied on VBAT pad over 3.5V; • If ON/OFF key function needed, the signal SWITCH_ON could be defined as power key to turn on the system by pulling it up to VDD_LRTC. 2.1.2.
A8000 User Guide Confidential • Receive a voice or data call from network to wake up A8000; • Receive a SMS from network to wake up A8000; • Hardware interrupts (such as Key press or GPIO interrupt). 2.1.6 RESET_N RESET provides an external reset control signal for A8000 system. It should be noted that logic LOW level is an effective signal for RESET_N 2.2 UART Interface 2.2.
A8000 User Guide Confidential Logic low output GND 0.2 V Logic high output VDD_LIO -0.2 VDD_LIO V 2.3 SIM Interface 2.3.1 SIM Interface description The SIM interface supports the functionality of the GSM Phase 1 specification and also Support of speed enhancement as specified in GSM 11.11 Phase 2+ with baud rates up to 100K baud SIM (intended for use with a SIM application Tool-kit). A8000 support 1.8V or 3.0V SIM card,Table2-4 gives the SIM interface pins description.
A8000 User Guide Confidential LCD_DATA 70 O LCD data signal LCD_CLK 71 O LCD data transfer clock LCD_CS_N 72 O LCD chip select O LCD Register select (data or instruction) 74 O LCD reset 1,2,4,5,20,2 1,49,59,60 - Ground LCD_A0 LCD_RESET GND 73 2.6 ADC A8000 provides 2 auxiliary ADCs (General purpose analog to digital converter, ADC1, ADC2) for measurements of analog signal such as battery temperature, battery id and environment temperature etc.
A8000 User Guide Confidential 2.7 Backlight 2.7.1 Backlight Control Description With default setting, BACKLIGHT pin of A8000 is used to drive either keypad led or display backlight led. Table2-10 gives the BACKLIGHT pin description. Table2-10: Backlight pin description of A8000 Signal Name BACKLIGHT Pin No. 16 I/O Description O Keyboard or lcd backlight led control 2.8 Keypad Interface 2.8.
A8000 User Guide Confidential KEYPADCOL2 8 O Keypad array output KEYPADCOL3 9 O Keypad array output KEYPADCOL4 10 O Keypad array output O/I Keypad array input/output KEYPADCOL5/ KEYPADROW0 11 KEYPADROW1 12 I Keypad array input KEYPADROW2 13 I Keypad array input KEYPADROW3 14 I Keypad array input KEYPADROW4 15 I Keypad array input 2.9 IIC Interface 2.9.
A8000 User Guide Confidential Table2-13 Parallel port pins description of A8000 Signal Name Pin No.
A8000 User Guide Confidential 2.13 General Purpose Input Output (GPIO) If needed, Many signal pins of function interfaces such as KEYPAD, LCD,UART and IIC can be used as GPIO alternatively by software configuration, please refer to appendix table4-1 for application. 3 Electrical Characteristics and Reliability 3.1 Absolute Maximum Ratings Absolute maximum rating for power supply and voltage on digital and analog pins of A8000 are list in table3-1 as follows.
A8000 User Guide Confidential 3.4 Electrostatic Discharge Normally the module is designed inside customer terminal, so about Electrostatic Discharge (ESD) should be considered base on the requirement of terminal product. But for the module is protected against Electrostatic Discharge in conveyance and customer production, and some second level ESD protect design inside module.
A8000 User Guide Confidential Figure4-1(a) BOTTOM View Figure4-1(b) TOP View Figure4-1 A8000 appearance 4.2 Mounting A8000 onto the application platform Just solders A8000 on user’s application platform with pad to pad. 4.3 Pins Assignment Of A8000 Table4-1 The definition of board to board connector PIN No.
A8000 User Guide Confidential 9 KEYPADCOL3 Keypad array output3 GPIO CC interrupt input 10 KEYPADCOL4 Keypad array output4 GPIO CC interrupt input 11 KEYPADCOL5/KEYP ADROW0 Keypad array output5 or input1 GPIO CC interrupt input 12 KEYPADROW1 Keypad array input1 GPIO External interrupt input 13 KEYPADROW2 Keypad array input 2 GPIO 14 KEYPADROW3 Keypad array input 3 GPIO CC interrupt input 15 KEYPADROW4 Keypad array input 4 GPIO CC interrupt input 16 BACKLIGHT Keypad or LCD
A8000 User Guide Confidential 34 DATA01 Parallel port: data01 35 DATA02 Parallel port: data02 36 DATA03 Parallel port: data03 37 DATA04 Parallel port: data04 38 DATA05 39 DATA06 Parallel port: data06 40 DATA07 Parallel port: data07 41 EXT_CS Parallel port: chip select 42 RESET_N A8000 system reset 43 VDD_LRTC RTC power 2.0V 44 SWITCH_ON ON/OFF key 45 SIM_CLOCK SIM card clock 46 VDD_SIM SIM card power supply,1.8V/3.
A8000 User Guide Confidential 55 AIN_N2 Auxiliary MIC input-(differential) 56 AIN_P2 Auxiliary MIC input-(differential) 57 AIN_N1 Normal MIC input-(differential) 58 AIN_P1 Normal MIC input-(differential) 59 GND Ground 60 GND Ground 61 VBAT A8000 power supply(3.4V~4.2V) 62 VBAT A8000 power supply(3.4V~4.
A8000 User Guide Confidential 75 HOOT_DET Hook detect 76 GND Ground 77 GND GPIO External interrupt input Ground Notes:*CC interrupt is an interrupt detecting mechanism that means system will capture the contents of a timer on specific internal or external events, and they can compare a timer content with given values and modify output signals if they match. IMPORTANT NOTE: This module is intended for OEM integrator.
A8000 User Guide Confidential approved by the manufacturer could void the user's authority to operate this equipment. If the size of the end product is smaller than 8x10cm, then additional FCC part 15.19 statement is required to be available in the users manual: This device complies with Part 15 of FCC rules.