S4 Combo Secual / S4 Combo Vid Secual GSM and Landline Alarm System www.etiger.
Features - GSM/PSTN transmitter - Supports up to 30 remote controls, 50 wireless accessories and 50 RFID tags - Can store up to 5 phone numbers, 5 SMS numbers, and 2 CMS numbers (for systems connected to a Central Monitoring System) - Arm / disarm the system by SMS, phone call, or App (on iOS or Android) - Can be disarmed by RFID tag - Built-in siren (100dB) and call function from the panel - SMS alerts for power failure, power recovery and low battery - Audio surveillance of the site from distance - 2 x 80
Quick Start-up
Control Panel Layout (Front) LCD Display Arm Disarm LED Status Indicator (armed / disarmed) Stay (Home Mode) Call RFID Tag Reader SOS Control Panel Layout (Back) Monitoring MIC Tamper Switch Speaker SIM card Slot VCC Z1 GND SP GND LOCK P1 Output for wired sensors Wired sensors (24h zone) Wired siren 500mA Electronic lock Adapter interface Power On/Off Battery Compartment Telephone Interface 4 Power Switch Power Supply Interface
The S4 Combo Secual features a dual GSM and PSTN transmitter. This means that the control panel of your alarm system will communicate with you either through a SIM card (GSM module) or through your telephone landline (PSTN module). Important Before using the S4 Combo Secual in GSM mode, you need to purchase a SIM card that works on the GSM network with 850 / 900 / 1800 / 1900 MHz frequency. We recommend you to subscribe to a plan with unlimited texts and one hour of voice.
Mount the Control Panel Before mounting the control panel on the wall, make sure the reception of the GSM signal is sufficient. Fix the wall-mounting bracket on the wall with screws. Wedge the panel on the bracket, make sure they fit well. First Operations Select GSM / PSTN Mode Refer to the instructions page 12 to deactivate the mode you do not want to use.
Default admin code is 123456. To change the admin code, refer to the instructions "Admin Code" on page 12. If the accessory has already been registered, the control panel will beep twice. The first accessory registered is assigned to zone 1, the second accessory registered is assigned to zone 2, etc. Zones 1 to 9 can be renamed. Zones 10 to 50 cannot be renamed (refer to the instructions on page 22 to learn how to rename zones).
Control Panel Operations
Setup from the Control Panel Press the Arm button " " on the control panel. The control panel beeps once: the system is armed. The control panel of your alarm system features an LCD display that enables you to navigate through the menu of the control panel and set up your alarm system. Disarm the System Type your user code and press the Disarm button " " on the control panel. The control panel beeps twice: the system is disarmed. Home Mode All the sensors assigned to the Normal zone are armed.
Main Menu Sub Menu 1 PHONE NUMBERS SMS NUM [1~5] IS: Sub Menu 2 PHONE [1~5] IS: - CMS NUM [1~2] IS: ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES 10 Sub Menu 3 - ADD A NEW - REMOTE DELETE ALL? 1=YES DELETE ONE ENTER 01-30: 0=NO ADD A NEW PLS CONNECT RFID TAG DELETE ALL? 1=YES DELETE ONE ENTER 01-50 ADD A NEW NORMAL SENSOR HOME SENSOR DELAY SENSOR 24 HOUR SENSOR DELETE ALL? 1=YES DELETE ONE ENTER 01-50: WIRELESS SENSORS TEST MODE - 0=NO 0=NO
Select the phone or SMS number you want to edit, type in the phone number and confirm with the key "Enter". Use the key " " to clear. 5 phone numbers, 5 SMS numbers and 2 CMS numbers can be stored in the control panel. Note If you want to set a CMS center phone number, please refer to the instructions on page 17 of this manual.
Main Menu SYSTEM SETTINGS SYSTEM SETTINGS SYSTEM SETTINGS Sub Menu 1 Sub Menu 2 DATE AND TIME YYYY-MM-DD TIME Sub Menu 3 ENTRY DELAY 000-300 EXIT DELAY 000-300 ENTRY EXIT DELAY AUTO ARM / DISARM AUTO ARM TIME <00:00> AUTO DISARM TIME <00:00> ON OR OFF? SYSTEM SETTINGS CONTROL BY PHONE ON / OFF - SYSTEM SETTINGS LINECUT ALARM ON / OFF - SYSTEM SETTINGS GSM FAIL TIP ON / OFF SYSTEM SETTINGS KEYPAD TONES ON / OFF - ADMIN CODE 123456 USER CODE 1234 DURESS CODE 0000 OPEN DO
Note (e.g. 2014-06-20 14H30) Time is calculated in seconds. The Entry and Exit Delay can be set from 0 to 300 seconds. The entry and exit delay is only for sensors connected as Delay Zone accessories (see "Wireless" on page 10). The Entry Delay gives you time to disarm the system on the control panel without triggering an alarm. The Exit Delay gives you time to arm the system on the control panel and leave your home without triggering an alarm.
Main Menu SYSTEM SETTINGS Sub Menu 1 Sub Menu 2 Sub Menu 3 RINGING TIMES <0-9> - WIRED SIREN SYSTEM SETTINGS ARM/DISARM TONE IN SIREN VOLUME 0-1 (0=MUTE) SIREN ALERT TIME 3 MIN SIREN SETUP BUILT-IN SIREN WIRELESS SIREN SIREN SWITCH ARM/DISARM TONE SIREN SWITCH ARM/DISARM TONE USER ID (4 DIGITS):0000 - ARM UPLOAD ON / OFF - DISARM UPLOAD ON / OFF - SYSTEM SETTINGS CALL RECYCLE <0-9> SYSTEM SETTINGS BACKLIGHT TIME
Note This function enables you to determine the number of times the control panel will ring before taking your call (for control by phone call). Quick start-up Comments Wired siren refers to a siren connected to the control panel by wire. Built-in siren refers to the siren featured in the control panel. More information on page 17 of this manual This information is supplied by your CMS center.
Control by Phone Call This feature is available only after having enabled it from the control panel, as explained on page 12 of this manual. Method 1 When an alarm has been triggered, the control panel dials the stored phone numbers. When you pick up the phone, follow the voice instructions to control the panel from distance (refer to the instructions in the table below). Method 2 1.
Every detector can be assigned to 4 different categories of zones: Home Zone, Delay Zone, Normal Zone and 24-H Zone. To assign a detector to a zone, follow the instructions on page 10 of this manual (the zone will be assigned at the time of connection of the accessory). 24h zone Regardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm. It is recommended to assign smoke detectors, gas detectors and outdoor beam sensors to the 24-H zone.
...
Quick start-up SMS Operations IMPORTANT: BEFORE USING FOR THE FIRST TIME INSERT A SIM CARD IN THE CONTROL PANEL BEFORE STARTING SMS OPERATIONS. SAVE A SMS NUMBER IN THE CONTROL PANEL (USING THE CONTROL PANEL). Only stored numbers can control and configure the system. (Refer to the instructions page 10) Each SMS operation defined in this user manual will be illustrated as follows: You send: The first blue speech bubble is the SMS command sent by the user.
Disarm the System Settings Enquiry Send: Send: 0 00 System disarmed. System:Disarmed AC power:on Arm the System Note The values indicated hereinabove will change after having set up the system. Send: 1 System armed. Home Mode Send: 2 System in home mode.
Store Phone Numbers for SMS Notifications Send: Send: Quick start-up Store Phone Numbers 5 6 Copy, paste, then edit (case sensitive): Copy, paste, then edit (case sensitive): Phone numbers: 1. 067890033 2. 067890022 3. 067890011 4. 067890000 5. SMS numbers: 1. 067890033 2. 067890022 3. 067890011 4. 067890000 5. Ok Safety and Troubleshooting Note The first SMS number will receive SMS notifications when the system is disarmed by RFID tag.
Rename Zones SMS Alert for Accessory Low Battery (available for two-way acessories such as Motion Detectors) Send "91~99". For example for zone 1, send: For accessories assigned to zones that have been renamed, an SMS will be sent under the format “Zone name + low battery”. 91 Zones names: 1. Copy, paste, then edit (case sensitive): Zones names: 1.Entrance door sensor Ok Note Zones 1 to 9 can be renamed. The name of the zone cannot consist of more than 30 Latin characters.
Entry and Exit Delay Time Send: Send: 10 11 Entry delay time(0-300sec):0 Exit delay time(0-300sec):0 Copy, paste, then edit (case sensitive): Copy, paste, then edit (case sensitive): This function can be used if you do not want to bring a remote control or a RFID tag with you. When you arm the system, the system will be armed after the delay set. When you disarm the system, the system will be disarmed after the delay set.
Siren Volume and Ringing Time Disarm Password Send: Send: 12 13 Siren volume(0=Mute,1=High):1 Siren ringing time(1-9min):5 Copy, paste, then edit (case sensitive): Disarm password (4 digits): 1234 Copy, paste, then edit (case sensitive): Siren volume(0=Mute,1=High):0 Siren ringing time(1-9min):1 Ok 24 Disarm password (4 digits): 8888 Ok
Send the code corresponding to the language you want to set. For example, for English, send “0001”. Restore System to Factory Settings by SMS Send: 0000 Ok Ok Refer to the table below for the full list of languages: Note Only stored numbers can send the SMS to restore factory settings. SMS Operations 0008 German 0009 Spanish 0010 Finnish 0011 Norwegian 0012 Arabic 0013 Farsi The settings will be restored to default values. Stored phone numbers and connected accessories will not be deleted.
Accessories 26
Disarm SOS Quick start-up Wireless Remote Control LED indicator Arm Press the Arm button " " to arm the alarm system. The LED indicator lights up (the control panel beeps once). The system is armed. SMS Operations If an intruder is detected, the siren rings out. (The siren turns off after 5 minutes as per default settings.) In the meantime, the system dials the stored phone numbers automatically.
Mute Mode Press the Home Mode button " " and then the Arm " " or Disarm " " button immediately after. Doing so, the control panel does not beep when you arm or disarm your system. Emergency Mode Regardless the status of the system, the alarm is triggered when the SOS button "SOS" is pressed on the remote control. At the same time, the control panel sends a notification by SMS ("RC-01 SOS", 01 being the remote control's number) and dials the pre-stored phone numbers.
Features The ES-D1A is a high performance wireless motion detector boasting a digital dualcore fuzzy logic infrared control chip with intelligent analysis. This technology identifies interferences created by body motion and reduces the false alarm rate. Design PCB Layout 1 LED working indicator 2 Infrared sensor** AA 1.5V LR6 1. LED indicator 2. Detection window 3. Bracket **Infrared sensor Detects the infrared rays released by human body motion. Do not touch the surface. Keep the surface clean.
Usage Open the case and remove the battery activation strip. Self-testing will start for 30 seconds. When the sensor is in operation, if it is triggered more than twice within 3 minutes, it will switch to standby mode to save power. If no movement is detected within the next 3 minutes, the sensor goes back to working mode. Connect Button Register in the control panel Navigate through the menu of the control panel and reach "ADD A NEW" (Wireless Sensor).
A. After the installation, turn the detector on. After one minute of self-testing, press the test button, walk in the scope of detection and watch the LED indicator to make sure the detector is working. Quick start-up Testing B. The LED indicator blinks once when body movement is detected. Specifications Control Panel Operations C. Adjust the detector angle to achieve the best detection performance. Detection Scope Power supply DC 3V (AA 1.
Wireless Door / Window Contact Features The ES-D3A is a Door / Window Contact that can be installed on doors, windows, and any other objects that open and close. The sensor sends a signal to the control panel when the magnet is separated from the transmitter. Thanks to the tamper switch, any attempt to remove the cover of the Door / Window Contact will trigger the alarm.
Specifications Static current ≤ 30 uA Alarm current ≤ 15 mA SMS Operations Power supply DC 12V (A23 12V Battery x 1) Control Panel Operations - Open the case and remove the battery activation strip. - Mount the sensor on the door and the magnet on the door frame. - Make sure the magnet is placed above the transmitter. - Mount the magnet max. 1 cm away from the transmitter and secure the transmitter and magnet with doublesided tape or screws.
RFID Tag Features The RFID tag enables you to disarm your system or unlock electronic door locks. Register in the control panel Refer to the instructions in the table page 10 of this manual (“RFID TAG”). Specifications Dimensions 45 x 30 x 7 mm Register an Additional eTiger Siren The control panel of the S4 features a built-in 100 dB siren. Your eTiger security systems supports additional indoor and/or outdoor sirens so to enable you to extend your system according to your needs.
Troubleshooting and Safety Instructions
FAQ Issue No response following interaction with the control panel Cause of malfunction Solution The control panel is switched off Open the battery compartment and turn the power on Electricity grid failure Contact your electricity provider Backup batteries are empty Plug the AC adapter to an AC socket The control panel is not in Connection mode Make sure the control panel is in Connexion mode Accessories have not been triggered for connection Make sure the accessory is triggered so to send a s
For a safer use of the product and to optimize the lifespan of the product, we recommend you to follow the precautions below: - The wireless accessories must be connected to the control panel. Low power voltage may affect transmission distance. Do not press the SOS key on the remote control if it is unnecessary to avoid disturbing neighborhood. Check the system regularly to make sure the system works properly.
Standards This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment. For further information, please contact your local or regional authorities.
FCC Information and Copyright This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
www.etiger.