User's Manual

EN
Box Content
1 x Door / Window Contact
1 x User Manual
Transmitter
Magnet
www.etiger.com
ES-D3A
Wireless Door / Window Contact
PCB Layout
LED working indicator
Jumpers for zone setup
A23 12V Baery
Tamper switch
Infrared sensor: Detects the infrared rays released by human body
motion. Do not touch the surface. Keep the surface clean.
Tamper switch: When the alarm system is armed, the tamper switch
will trigger the alarm if the case is opened.
Jumpers for Zone setup: The jumpers enable you to assign the
detector to a specic zone. Refer to the user manual of your alarm
system for more information on zone set up.
Standards
This product bears the selective sorting symbol for waste electrical
and electronic equipment (WEEE). This means that this product must
be handled pursuant to European Directive 2002/96/EC in order to be
recycled or dismantled to minimize its impact on the environment. For
further information, please contact your local or regional authorities.
Electronic products not included in the selective sorting process are
potentially dangerous for the environment and human health due to
the presence of hazardous substances.
In compliance with European laws.
This product was designed and manufactured in compliance with
Directive 2002/95/EC of the European Parliament and of the Council on
the restriction of use of certain hazardous substances in electrical and
electronic equipment (RoHS Directive - RoHS) and is deemed to comply
with the maximum concentration values set by the European Technical
Adaptation Committee (TAC).
Manufactured in China.
Images, illustrations and text are non-contractual. ETIGER and the ETIGER logo are
registered trademarks and the property of ETIGER.
Copyright © 2014 ETIGER. All rights reserved.
Installation
- Open the case and remove the battery activation strip.
- Mount the sensor on the door and the magnet on the door frame.
- Make sure the magnet is placed above of the transmitter.
- Mount the magnet max. 1cm away from the transmitter and secure the
transmitter and magnet with double-sided tape or screws.
- Avoid mounting the sensor in areas with a large amount of metal or
electrical wiring, such as a furnace or utility room.
Register the detector in the alarm system
Switch to Connection Mode on the control panel. Separate the magnet
of the detector from its transmitter. The control panel beeps once: the
detector is registered. If you hear two beeps, the detector has already
been connected.
To check if the registration
is complete, arm the system
and separate the magnet
from the transmitter again
by opening the door or
window on which it is
installed. If the siren rings
out, the registration is
successful.
Specications
Power Supply:
DC 12V (A23 12V battery x1)
Static current:
≤30 uA
Alarm current:
≤40 mA
Transmission distance
≤ 80 m (in open area)
Radio-frequency:
315MHz (±75KHz)
Housing material:
ABS plastic
Operating conditions:
Temperature: -10°C ~ +55°C
Relative Humidity: ≤80% (non-con-
densing)
Transmitter dimensions:
60 x 43 x 18 mm
Magnet dimensions:
19 x 43 x 18 mm
LED indications
Blinks once
The door or window is open and the transmitter sends a signal to the
control panel.
Blinks quickly
Low power indication: the batteries must be replaced.
ETIGER EUROPE
Rue de la Loi, 25, 7100 La Louvière, Belgique
service@etiger.com
This user manual is available in other languages at
www.etiger.com/eu/support
ES-D3A-UM-EN20140724:2.0-W