To: AirWalk communications, Co., Ltd. User’s Manual Model no.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 1 / 25 Revision history Rev. Date 1.0 Apr.25, 2008 1.2 Jul.2, 2008 Chap. Changes Note Design Document for First draft 1 1. sector configuration added in 2. port setting added in 3.2.1 Slim RU Version 1.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 2 / 25 Table of Contents 1. Introduction .......................................................................................... 3 2. Installation ............................................................................................ 4 3. Program configuration............................................................................. 5 3.1. GUI ......................................................................
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 3 / 25 1. Introduction It is monitor and controls all the functions of Slim-RU series based on graphic user interface (GUI) or Man Machine Interface (MMI). Slim-RU GUI program offers straight forward user interface under Windows 2000 or Windows XP operating system. Therefore it needs only short training course for maintenance technicians. Also MMI program performs all functions of GUI.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 4 / 25 2. Installation To install Slim-RU GUI program, double click “Setup_SLIM_RU_2008.06.20_V1.4.exe”. Then InstallSheild Wizard shows like figure 1. Click “Next” button. Figure1. Initial page Click “Install” button like figure 2. Figure2. Installation InstallShield Wizard shows the last page when it is done like figure 3. Click “finish” button. Finally, installation is done.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 5 / 25 Figure3. Finish 3. Program configuration 3.1. GUI 3.1.1. Main window It offers monitoring, setting, and downloading firmware to Slim-RU. You can select whatever you want to handle. * NOTE : When the cable connects Master Slim-RU, you can handle all Slim-RUs such as master, slave1, and slave2. But if you connect it to slave 1 or slave 2, you can handle only it Figure4.
Reference User Manual Revision 3.1.2. System window It offers monitoring and setting in details Figure5. System window For details, it offers “hidden window” with pressing “ctrl + p” Figure6. Hidden window Design Document for Slim RU Version 1.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 3.1.2.1. System info Items Descriptions F/W Version Shows Frimware Version H/W Version Shows H/W Version Description Shows brief system information PSU TYPE Shows PSU type and information HPA Power Shows HPA power in dBm HPA Temp Shows HPA temperature Equip Temp Shows Slim-RU temperature Sys Version Shows system version Sys Capacity Shows Slim-RU capacity Sys Freq. Shows sys Frequency 3.1.2.2.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 3.1.2.3. History info Items Descriptions Manufacture Date Shows the date of RRCU manufacturing F/W Build Date Shows the date of firmware building Install Date Shows the date of Slim-RU installation Repair Count Shows the number of Slim-RU repair Repair Date Shows the date of repair date Repair Code Shows the date of repair history 3.1.2.4.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 9 / 25 * Controller DIP switch It sets details of PSU like table. SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 ON DC/DC 48V/27V - - - - - - OFF AC/DC 27V/27V - - - - - - 3.1.2.6. Down load File open: To select file to be downloaded click it. Download: It starts download to Slim-RU. The figure shows in the processing with file progress bar Cancel: It cancel download Figure8. Download proceding 3.2. MMI 3.2.1.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 10 / 25 Then you can see below terminal screen with prompt “SLIM_RU:MST:> like figure 10 (b) when you hit “Enter” key several times. If prompt is “SLIM_RU:###” like figure XXX (a), it means no communication with upper system, e.g. AW96 if you connect master of Slim-RU or master if you connect slave 1 or 2 of Slim-RU. Please confirm it. (a) No connections with upper system (b) Connected properly Figure10.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 11 / 25 * reset: reboots Slim-RU without manual cycling. Reboot process is shown below Figure12. command example “reset” * status [master/slave1/slave2] : shows the status that you connected briefly without any option like figure 13 (a) or with options [master/slave1/slave2] like (b) to (d). But you cannot see your upper system.
Reference User Manual Revision (c) Status with option “slave1” Design Document for Slim RU Version 1.2 IR Page 12 / 25 (d) Status with option “slave2” Figure13.
Reference User Manual Revision Design Document for Slim RU Version 1.
Reference User Manual Revision testcmd allalm Design Document for Slim RU Version 1.2 IR Page 14 / 25 Report all fake alarm to upper system (ex.
Reference User Manual Revision testcmd Design Document for Slim RU Version 1.2 IR hfa Report fake HPA fan alarm to upper system [on/off] (ex.) confirm “HPA FAN” after “testcmd hfa on” testcmd hdcf Report HPA DC fail alarm to upper system (ex.
Reference User Manual Revision testcmd HL2F Report fake LNA_2 alarm to upper system [on/off] (ex.) confirm “LNA_2” after “HL2F Design Document for Slim RU Version 1.2 IR Page 16 / 25 ” testcmd [on/off] HL1F Report fake LNA_1 alarm to upper system (ex.
Reference User Manual Revision testcmd [on/off] Design Document for Slim RU Version 1.2 IR HOVT Report fake over temperature alarm to upper system (ex.) confirm “Over temp” after “testcmd hovt on” testcmd HVSWR Report fake HPA VSWR alarm to upper system [on/off] (ex.
Design Document for Slim RU Version 1.2 Reference User Manual Revision Testcmd [on/off] testcmd [on/off] IR Page HOVP Report fake HPA over power alarm to upper system (ex.) confirm “Over power” after “testcmd hovp on” poh Report fake over heat alarm to upper system (ex.
Reference User Manual Revision testcmd [on/off] Design Document for Slim RU Version 1.2 IR Page PDCF Report fake PSU DC fail alarm to upper system (ex.) confirm “PSU DC Fail” after “testcmd pdcf on” testcmd PFF Report fake PSU fan fail alarm to upper system [on/off] (ex.
Reference User Manual Revision testcmd [on/off] testcmd [on/off] Design Document for Slim RU Version 1.2 IR Page PACF Report fake HPA fan alarm to upper system (ex.) confirm “PSU AC failAN” after “testcmd pacf on” RPOH Report fake RPSU over heat alarm to upper system (ex.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page testcmd RPDCF Report fake RPSU DC fail alarm to upper system [on/off] (ex.) confirm “RPSU DC fail” after “testcmd rpdcf on” testcmd RPFF Report fake RPSU fan alarm to upper system [on/off] (ex.
Design Document for Slim RU Version 1.2 Reference User Manual Revision IR Page 22 / 25 3.2.4. Emergency recovery mode 3.2.4.1. Entering You can download firmware when Slim-RU does not operate properly. Press “enter” within 7 sec. when it boots up. Fig.14 shows the screen when it enters on emergency recovery mode Figure14. Entering emergency recovery mode * You can close window or disconnect com port when you want finish.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 23 / 25 3.2.4.3. Download Start download procedure with click “download”. You can download firmware when Slim-RU does not operate. It will automatically reboot when it is done. Figure16.
Reference User Manual Revision Design Document for Slim RU Version 1.2 IR Page 24 / 25 Caution: The user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.