V:IoT APG2-PCIA-A module Installation manual Version: 1.1 Date: 2019-03-21 SES-imagotag GmbH I St. Peter Gürtel 10b I A-8042 Graz - AUSTRIA FB: FN350927w I HG : Graz I UID : ATU65936017 I WEEE : DE 65879240 T. +43 (0) 5 98 09-400 I F. +43 (0) 5 98 09-900 I E. office.at@ses-imagotag.com I www.ses-imagotag.
Table of Contents 1 General .......................................................................................................................... 3 2 Description ..................................................................................................................... 5 3 Specification ................................................................................................................... 6 4 Installation .....................................................................
1 General This is OEM installation manual for APG2-PCIA-A module. If you have any problems with installation, please contact the SES-imagotag Support Team (support.at@ses-imagotag.com). If there are questions regarding AP in which this module is installed, please contact AP manufacturer directly. Figure 1 – APG2-PCIA-A module photo Figure 2 – Retail IoT Connector Cisco Aironet 3800 SES-imagotag GmbH I St.
Figure 3 – Retail IoT Connector Cisco Aironet 3800 disassembled (APG2-PCIA-A module + Retail IoT Connector Cisco Aironet 3800 base board) SES-imagotag GmbH I St. Peter Gürtel 10b I A-8042 Graz - AUSTRIA FB: FN350927w I HG : Graz I UID : ATU65936017 I WEEE : DE 65879240 T. +43 (0) 5 98 09-400 I F. +43 (0) 5 98 09-900 I E. office.at@ses-imagotag.com I www.ses-imagotag.
2 Description APG2-PCIA-A module is responsible for transmitting and receiving messages from SESImagotag electronic shelf label (ESL) network. It cannot work standalone and must be plugged into another device (host device), usually Access-point (AP), which supports the module. Configuration and startup of the module is done over the host device. This manual is not covering this because it is device dependent. Separate instruction manual is provided with each supporting host device.
3 Specification • • • • • • • • • Chipset: Texas instruments CC2650 Radio frequency: 2404-2480 MHz Output power: Max. 10 dBm Protocol: proprietary Modulation: MSK Data Rate: 250 kbps Supply voltage: 3.3V Supply power: Max. 0.5W Operating temperature: 0-60 °C SES-imagotag GmbH I St. Peter Gürtel 10b I A-8042 Graz - AUSTRIA FB: FN350927w I HG : Graz I UID : ATU65936017 I WEEE : DE 65879240 T. +43 (0) 5 98 09-400 I F. +43 (0) 5 98 09-900 I E. office.at@ses-imagotag.com I www.ses-imagotag.
4 Installation This module must be installed by trained professionals only. It is not allowed for end user to install, remove or modify any of device connections. This module is ESD sensitive device. Make sure to discharge properly before touching it. Base board must be powered off. Grasp the module by its edges and align the notch in the connector on the base board. Insert the module into connector at around 30-degree angle. Lower the other end of the module and make sure it is aligned with screw holes.
5 Labeling Figure 5 – Retail IoT Connector Cisco Aironet 3800 Label PCIA-APG2-A Module itself does not have a label. It is not sold by itself and it is used only in our equipment. Our equipment´s label contains FCC ID and IC ID of the APG2-PCIA-A Module as on the example above (Figure 5). SES-imagotag GmbH I St. Peter Gürtel 10b I A-8042 Graz - AUSTRIA FB: FN350927w I HG : Graz I UID : ATU65936017 I WEEE : DE 65879240 T. +43 (0) 5 98 09-400 I F. +43 (0) 5 98 09-900 I E. office.at@ses-imagotag.com I www.
6 Declaration FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate the equipment.