1
A FlexNode Line Powered assembly requires a single
FlexNode Line Powered and the mounting kit.
FlexNode Line Powered Installation Parts
Quick Start Guide: FlexNode Line Powered Radio (NA)
Pull the power cable (not provided by Sensys Networks) through the conduit to mounting
location for the FlexNode Line Powered. Ensure the power cable is not connected to the power
source. Make sure the power cable has enough slack for drip loop. Assemble the mounting plate
onto the pole. Attach mounting arm to mounting plate. Complete the remaining assembly steps
for the FlexNode Line Powered inside the bucket before attaching it to mounting arm.
Please refer to Repeater Installation Guide for detailed instructions for mounting assembly.
Prepare Mounting Location
Strip the wires to expose approximately 0.27 in (7 mm)
of the conductor from the power cable to prepare for
connecting to green terminal block inside repeater.
Strip Wires
Remove reusable cotter pins and pull out both retention
rods. Remove the FlexRepeat3 Line Powered cover.
Pull Cover Off Repeater
Remove the bulkhead connector
and remove and discard the plug.
Remove Plug