User's Manual

AMR-XXX
Sensus RadioRead
Model 510R2 – Non Pit Unit
Installation Instructions-Draft
Page 1 of 4
The following information contains installation instructions for the
Sensus Model 510R2 MXU.
Note: This installation sheet is only for installation of the Sensus
Model 510R2. For instructions on installing other AMR devices,
please request and refer to the individual installation instruc-
tion for those devices.
The Model 510R2 MXU is designed for non pit, non submersible
applications and is available for both a single port and dual port
operation. The Model 510R2 can be mounted indoors or outdoors
where it is not subject to submergence. The Model 510R2 is not
intended for outdoor meter pits or vaults. The unit can be installed
with either a TouchCoupler connection or wire connection. Please
refer to AMR-326 for compatibility.
1. Sensus TouchPad
2. TouchPad Cover Assembly Complete
3. TouchPad Cover
4. TouchPad Fastener
5. TouchPad Cover Locking Clip
6. Model 510R2 Radio (Front View)
7. Model 5102 Radio TouchCoupler Enabled Assembly
(Rear View with TouchPad Cover)
Single Port – TouchCoupler Installation
1. Perform a TouchRead on TouchPad(s) to insure TouchRead to
the encoder works.
2. Taking a completely assembled Model 5102 Radio and Touch-
Coupler Spacer with TouchPad Cover, align the TouchPad
Cover over an installed Sensus TouchPad.
Important
General Information
Definitions
1
2
6
7
3
4
5
TouchCoupler - Installation Instructions
3. Place the unit over the TouchPad and press firmly until secure.
4. For additional support (optional), open the MXU door and pre-
drill the holes designed to fasten the unit to the wall. (Fastener
holes are located above the battery).
5. Secure the unit to the wall with screws.
6. Once unit is secured with the screws, close the door of the
MXU and tighten security screw until unit is firmly sealed.
7. Once the unit is closed and secured, begin the activation
process. (See Activate Radio section).
8. Coil excess wire and then secure to the body of the meter or
service line in a presentable manner.
Single Port - Remote TouchCoupler
Installation
Remote TouchCoupler installations are an option when a direct
TouchCoupler (Sensus only) connection cannot be completed due
to physical limitations. Before proceeding with the installation of a
remote TouchCoupler application, be sure to find a location free
from obstacles that would interfere with the connection from the
TouchPad Cover to the MXU.
Wire stripping tool
Screwdriver - Small standard head for terminal connections
SR II security screw socket with 1/4" nut driver or ratchet wrench
Power drill and bit (1/4")
8 x 1" sheet metal screws
1. Find a suitable location for the installation where the TouchPad
Cover and MXU installation will be free from interference.
Note: If TouchPad is not already installed, install TouchPad allowing
enough room for the TouchPad Cover to be securely placed over
the installed TouchPad.
Recommended Tools and Materials
amr_321.fm Page 1 Tuesday, July 18, 2006 3:55 PM