OEM100 AND OEM1000 MODULES VERSION 1.
HARDWARE MANUAL OEM100 and OEM1000 Modules VERSION 1.5 Sensicast Systems, Inc. 220-3 Reservoir Street Needham, MA 02494 Phone 781.453.2555 support@sensicast.com www.sensicast.
Part # 1390 – OEM100 and OEM1000 Module Hardware Manual Copyright ©2006 Sensicast Systems, Inc. All rights reserved. Sensicast and SensiNet are trademarks of Sensicast Systems, Inc. in the United States and/or other countries. All other trademarks are property of their respective owners. In the interest of product improvement, information and specifications herein are subject to change without notice. www.sensicast.
FCC Statement The OEM100 and OEM1000 equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by Sensicast could void the user’s authority to operate this equipment.
Introduction This design guide is intended to provide a good understanding of the functionality of the OEM100 or OEM1000 module. The intended audience is the engineer responsible for integrating the OEM module into a product. Description and Specifications The OEM100 or OEM1000 is a component of the Sensicast H900 Wireless Sensor Network Platform – a completely self-configuring, self-healing, power managed sensor network.
The OEM100/OEM1000 can be preloaded with a temperature and humidity sensor. Please contact Sensicast for temperature and humidity specifications. Connectors The primary interconnection is P3, the 41 position board to board, header (Hirose p/n DF9A-41P-1V(20); mates with: Hirose p/n DF9A-41S-1V(20)) on the bottom of the assembly. Optionally, power can be brought to the board through P5, a two position, right angle wire to board, header (JST p/n S2B-PH-K-S, mate: JST p/n PHR-2).
11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 J5 Pin 1 2 AN1 SDA AN0 DIG3/CNT3 GND RTS RESET# CTS TCK SCK TMS SPARE1 TDI Input I/O Input I/O Ground Output Input Input Input I/O Input I/O Input TDO Output TXD1 Output RXD1 Input FLAG0 Output VSUPPLY VSUPPLY GND GND Power Power Ground Ground Analog In Two-wire interface data Analog In General I/O / external interrupt / counter in Ground UART RTS Reset (active low) UART CTS JTAG programming Two-wire in
General I/O / external interrupt / counter in: This is a bidirectional, CMOS level, digital signal running between VCC and GND. It can be configured as external, hardware interrupt or as an input to a counter. Analog In: These are analog inputs. Initialization: These pins are digital inputs and outputs used during the initialization of the module. Two-wire interface: Both SDA and SCK have 10K ohm pull-ups to VCC. The module acts as the master on the bus.
Recommended PCB Layout The OEM module occupies 2.35” by 1.58” and is designed to plug into a PCB mounted, 41 position, Hirose DF9 receptacle (Hirose p/n DF9A-41S-1V(20)). Please refer to Hirose’s documentation for more information about this connector. There are three mounting holes designed to accommodate 4mm plastic stacking posts (Richco p/n MDLSP1-04M-01).
Battery life Range Connector options Duty cycle Antenna LEDs Up to 3 years with a 2/3A Lithium battery using a 2 minute report interval (sensor dependent) Up to 1000’ (outdoors, line of sight) (1 mile OEM1000) Up to 300’ (typical indoor conditions) (1000 feet OEM1000) Two (2) analog input lines Six (6) digital I/O lines Two wire interface bus UART (TX, RX, RTS and CTS) Remotely user-adjustable (default 3 minutes) Board mounted, omni-directional antenna included 3 diagnostic LEDs (red, yellow and green) A
P1 - 10 position (2x5) 0.