OEM100 MODULE VERSION 1.
HARDWARE MANUAL OEM100 Module VERSION 1.1 Sensicast Systems, Inc. 220-3 Reservoir Street Needham, MA 02494 Phone 781.453.2555 support@sensicast.com www.sensicast.
Part # 1390 – OEM100 Module Hardware Manual Copyright 2004 Sensicast Systems, Inc. All rights reserved. Sensicast and SensiNet are trademarks of Sensicast Systems, Inc. in the United States and/or other countries. All other trademarks are property of their respective owners. In the interest of product improvement, information and specifications herein are subject to change without notice. www.sensicast.
FCC Statement The H900 equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by Sensicast could void the user’s authority to operate this equipment.
Introduction This design guide is intended to provide a good understanding of the functionality of the OEM100 module. The intended audience is the engineer responsible for integrating the OEM100 into a product. Description and Specifications The OEM100 is a component of the Sensicast H900 Wireless Sensor Network Platform – a completely selfconfiguring, self-healing, power managed sensor network.
Connectors The primary interconnection is P3, the 41 position board to board, header (Hirose p/n DF9A-41P-1V(20); mates with: Hirose p/n DF9A-41S-1V(20)) on the bottom of the assembly. Optionally, power can be brought to the board through P5, a two position, right angle wire to board, header (JST p/n S2B-PH-K-S, mate: JST p/n PHR-2).
14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 J5 Pin 1 2 DIG3/CNT3 GND RTS RESET# CTS TCK SCK TMS SPARE1 TDI I/O Ground Output Input Input Input I/O Input I/O Input TDO Output TXD1 Output RXD1 Input FLAG0 Output VSUPPLY VSUPPLY GND GND Power Power Ground Ground General I/O / external interrupt / counter in Ground UART RTS Reset (active low) UART CTS JTAG programming Two-wire interface clock JTAG programming General I/O JTAG programming Reserved JTAG program
Initialization: These pins are digital inputs and outputs used during the initialization of the module. Two-wire interface: Both SDA and SCK have 10K ohm pull-ups to VCC. The module acts as the master on the bus. UART: Two wire (RX/TX) or four wire (RX/TX/CTS/RTS) logic level interface. Runs at 9600 baud, 8 data bits, no parity, 1 stop bit. Reset: An active low signal (RESET#) to reset the microcontroller. Used during debug and test of the module.
Recommended PCB Layout The OEM100 occupies 2.35” by 1.58” and is designed to plug into a PCB mounted, 41 position, Hirose DF9 receptacle (Hirose p/n DF9A-41S-1V(20)). Please refer to Hirose’s documentation for more information about this connector. There are three mounting holes designed to accommodate 4mm plastic stacking posts (Richco p/n MDLSP1-04M-01).
Battery life Range Connector options Duty cycle Antenna LEDs Up to 3 years with a 2/3A Lithium battery using a 2 minute report interval (sensor dependent) Up to 1000’ (outdoors, line of sight) Up to 300’ (typical indoor conditions) Two (2) analog input lines Six (6) digital I/O lines Two wire interface bus UART (TX, RX, RTS and CTS) Remotely user-adjustable (default 3 minutes) Board mounted, omni-directional antenna included 3 diagnostic LEDs (red, yellow and green) 8