Using the EM 9046
64 | Digital 9000
“Word clock” – Configuring the word clock
Via the “word clock” menu item, you can ...
switch between the following word clock signals:
internally generated word clock signal
external word clock signal
word clock signal of a built-in MAN card
adjust the sampling rate (44.1 kHz, 48.0 kHz, 88.2 kHz or 96.0 kHz)
with which – with an internally generated word clock signal – analog
signals are digitalized and output at the XLR-3 sockets A.
“Cable attn” – Displaying the cable attenuation and automatically
compensating for it
The EM 9046 receiver measures the cable attenuation between the
antenna boosters and the antenna inputs E and F and automatically
compensates for it:
during the boot routine
if both antenna boosters are connected or replaced
If only one antenna booster is connected or replaced, the cable attenu-
ation will not be measured.
To manually initiate the compensation of the cable attenuation:
In “sys” operating mode, turn the jog dial until “cable attn” appears.
Press the jog dial.
“Press SAVE to calibrate” is displayed on the display panel.
Pres the button.
During the measurement, the channel status display A displays “Cali-
brating” for each channel. The receiver is muted for approx. 10 seconds.
Then the result of the measurement is displayed as follows:
internal: 44.1kHz
word clock
RF IN A: OK
RF IN B: OK
cable attn
473
800
A
A1.7
CH3