Media Control Protocol for ew G4 series

TI 1254 v1.0 - ew G4 | 9/37
Technical information
Media control protocol description
Response of cyclic attributes
Due to the fact that cyclic attributes are all sent in one go here is an example how it could look like
(only cyclic attributes are listed, but not the previously sent command).
For an EM device it could be
RF1 25 65 1<CR>
RF2 28 78 0<CR>
States 3 2<CR>
RF 50 1 1<CR>
AF 40 65 3<CR>
Bat 70<CR>
Msg Low_RF_Signal Low_Battery<CR>
Config 234<CR>
The order of the cycylic attributes is always the same.
Note:
The cyclic attribute before the ‚Config‘ attribute represents the warnings. In this example the status
is “Low_RF_Signal Low_Battery. If there is no warning there will be an “OK“ instead of the warning
messages (see following example for SR below).
For a SR device it could look like
Af 15 25 40 38 5<CR>
States 0 2<CR>
Msg OK<CR>
Config 555<CR>
So each cyclic attribute is separated by a semicolon. For more information about the single attri-
butes see the corresponding tables below.