Media Control Protocol for ew G4 series

TI 1254 v1.0 - ew G4 | 24/37
Technical information
Media control protocol description
AfOut [set and get]
Valid for device EM only
Description
The output can be controlled by applying this command. It is also possible to get the current status
of the output. By using relative parameters it is only possible to reach +18 dB. Values greater than
+18 dB can only be reached directly, for instance by using AfOut 24<CR>. By decrementing from
+24 dB down jumps directly to +21 dB and then directly to +18 dB.
Parameters
Name Value range Get request Set request Relative
change
AfOut value -24..+18(+24): AfOut value in dB.
Step size 3 dB.
- X Yes
Examples
AfOut –18<CR>
AfOut is set to –18 dB. Sennheiser device replies with AfOut -18<CR>.
AfOut 24<CR>
AfOut is set to 24 dB. Sennheiser device replies with AfOut 24<CR>.
AfOut #1<CR>
AfOut is incremented by 1 step size (3 dB) e.g. previous value –18 dB => new value –15 dB.
Sennheiser device replies with AfOut -15<CR>.
AfOut 25<CR>
1020: Value out of range [AfOut 25 ]<CR>.
AfOut<CR>
current value is sent to media control, e.g. AfOut 3<CR>.