Media Control Protocol for ew G4 series

TI 1254 v1.0 - ew G4 | 19/37
Technical information
Media control protocol description
Mute [set and get]
Valid for device EM and SR
Description
On an EM device this command mutes the output. It is called a Rx-Mute. If this command is applied
on a SR device it will not send the carrier frequency anymore. This is called Rf-Mute. For both devic-
es, SR and EM, the status of Rf-Mute respectively Rx-Mute can be read.
Parameters
Name Value range Get request Set request Relative
change
Mute 0: (Rx–/Rf–) Mute disabled
1: (Rx–/Rf–) Mute enabled
- X No
Examples
Mute 1<CR>
Mute is enabled. Sennheiser device replies with Mute 1<CR>.
Mute<CR>
Sennheiser‘s device replies with Mute 1<CR>.