Push 250 200 2<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic at-
tributes will be updated every time when any warning changes its state. No configuration attributes
will be updated on change. Sennheiser device replies with Push 250 200 2<CR>.
Push 250 200 3<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic attri-
butes will be updated every time when any warning changes its state. Configuration attributes will
be updated on change. Sennheiser device replies with Push 250 200 3<CR>.
Push 250 200 4<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic
attributes will be updated every time when either transmitter‘s pilot signal or transmitter‘s battery
status changes. No configuration attributes will be updated on change. Sennheiser device replies
with Push 250 200 4<CR>.
Push 250 200 5<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic
attributes will be updated every time when either transmitter‘s pilot signal or transmitter‘s battery
status changes. Configuration attributes will be updated on change. Sennheiser device replies with
Push 250 200 5<CR>.
Push 250 200 6<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic
attributes will be updated every time when either transmitter‘s pilot signal or transmitter‘s battery
status changes or when warning status changes on side of stationary devices (EM and SR). No
configuration attributes will be updated on change. Sennheiser device replies with Push 250 200
6<CR>.
Push 250 200 7<CR>
Cyclic attributes are updated every 200 ms for a duration of 250 seconds. Beside of this cyclic
attributes will be updated every time when either transmitter‘s pilot signal or transmitter‘s battery
status or when warning status changes on side of stationary devices (EM and SR). Configuration
attributes will be updated on change. Sennheiser device replies with Push 250 200 7<CR>.
Push 5 450 1<CR>
1020: Value out of range [ Push 5 450 1 ] <CR>. 450 does not meet required resolution.