System Specification - SpeechLine Digital Wireless

SYSTEM SPECIFICATION (V3.2)
SpeechLine Digital Wireless
3/28
SL Handheld DW
RF output power adaptive, up to 250 mW
(country-specific)
AF frequency response 50 to 20,000 Hz
Input sensitivity automatic sensitivity adjust-
ment
Power supply Accupack:
Batteries**:
BA 10
(Li-ion, 3.7 V)
2 x AA size battery
(1.5 V)
Operating time Accupack:
Batteries**:
typ. 15 h
typ. 10 h
Display LCD
Mute switch available
Weight
(without accupack)
approx. 262 g (0.58 lbs)
incl. microphone head
** optional accessory
SL Bodypack DW
RF output power adaptive, up to 250 mW
(country-specific)
AF frequency response Mic:
Line:
50 to 20,000 Hz
20 to 20,000 Hz
Max. input level Mic:
Line:
2.2 V RMS
3.3 V RMS
Line input impedance 1 MΩ
Input sensitivity automatic sensitivity adjust-
ment
Power supply Accupack:
Batteries**:
BA 30
(Li-ion, 3.7 V)
2 x AA size
battery (1.5 V)
Operating time Accupack
Batteries**:
typ. 15 h
typ. 11 h
AF connection socket 3.5 mm jack socket, lockable
Mic
Line
Weight
(without accupack)
approx. 88 g (0.19 lbs)
** optional accessory
SL Tablestand 133-S DW
AF frequency response 75 to 20,000 Hz
Max. input level 1.7 V RMS
Input impedance 30 kΩ
Power supply BA 40 accupack (Li-ion, 3.6 V)
Operating time Accupack: typ. 11 h
Relative humidity max. 95 %
Dimensions 166.7 x 120.2 x 47.9 mm
(6.56" x 4.73" x 1.88")
Weight approx. 660 g (1.46 lbs)
(without accupack)
Operating temperature 10 °C to 45 °C
(50 °F to 113 °F)
SL Tablestand 153-S DW
AF frequency response 75 to 20,000 Hz
Max. input level 1.7 V RMS
Input impedance 30 kΩ
Power supply BA 40 accupack (Li-ion, 3.6 V)
Operating time Accupack: typ. 10 h
Relative humidity max. 95 %
Dimensions 166.7 x 120.2 x 47.9 mm
(6.56" x 4.73" x 1.88")
Weight approx. 660 g (1.46 lbs)
(without accupack)
Operating temperature 10 °C to 45 °C
(50 °F to 113 °F)
SL Boundary 114-S DW
AF frequency response 40 to 20,000 Hz
Pickup pattern cardioid
Dynamic range < 100 dB(A)
Sensitivity 10 mV/PA
Power supply BA 40 accupack (Li-ion, 3.6 V)
Operating time Accupack: typ. 12 h
Relative air humidity max. 95 %
Temperature range* Operation:
Storage:
10 °C to 45 °C
(50 °F to 113 °F)
-20 °C to 70 °C
(-4 °F to 158 °F)
Dimensions 114 x 85.3 x 30.8 mm
(4.49" x 3.36" x 1.21")
Weight
(without accupack)
approx. 208 g (0.46 lbs)
* The temperature range is influenced by the battery
characteristics
Microphones
MME 865-1 MKE 1
Microphone type pre-polarized condenser microphone
Sensitivity 1.6 mV/Pa 5 mV/Pa
Pick-up pattern super-cardioid omni-directional
Max. SPL 152 dB SPL 142 dB SPL