Turnstile Mount Reader (XCESS)– Installation & Configuration Version 1.
Turnstile Mount Reader (XCESS) – Installation & Configuration Legal Notice The information presented is subject to change without notice. Semnox Solutions assumes no responsibility for inaccuracies contained herein. Copyright © 2017 Semnox Solutions Pvt Ltd. All rights reserved. Notice No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of Semnox Solutions.
Turnstile Mount Reader (XCESS) – Installation & Configuration Table of Contents ABOUT THIS DOCUMENT ......................................................................................................................... 3 INTRODUCTION........................................................................................................................................ 4 OPERATIONAL DESCRIPTION ................................................................................................................
Turnstile Mount Reader (XCESS) – Installation & Configuration About this document Purpose This document explains the installation and configuration of the Turnstile Mount Reader (XCESS). Product name: PARAFAIT READER 4 Model number: PARARDR005, PARARDR005-1, PARARDR005-2 FCC ID: G7H-SPRW002 Revision History - 2018 Nov. - First issue of the document.
Turnstile Mount Reader (XCESS) – Installation & Configuration Introduction Semnox has a powerful and robust access control system suitable for controlling entries into theme parks, theater entrances, gaming zones etc. Flap barriers, Tripod Turnstiles, Bridge Turnstiles etc. are used at the entrances. The turnstiles are integrated with RFID-based entry devices, or barcode scanners for cashless transactions. They provide access to only valid ticket holders.
Turnstile Mount Reader (XCESS) – Installation & Configuration XCESS Reader The following images show the XCESS Reader. In theme parks, different variants of the XCESS Reader maybe used based on the requirement. Depending on the usage there are 3 variants: • • • RFID controlled gates Barcode controlled gates Biometric plus RFID controlled gates The usage type is decided in the reader configuration. The config values are explained in the following section.
Turnstile Mount Reader (XCESS) – Installation & Configuration LAN Interface Board – Connections • If External LAN =1, the reader works in LAN Mode. LAN mode requires a hardwired cable. For LAN mode, Baudconfig value =0 and BaudChngRetry value=5. • If External LAN = 0 then the reader works in WiFi mode. For WiFi mode we need to setup SSID and password. For WiFi mode, Baudconfig value =1. If External Card Reader value is 0 then it supports RFID.
Turnstile Mount Reader (XCESS) – Installation & Configuration LAN Interface Board – Configuration LAN interface board is configured using the tool called Wiz105SR configuration tool. This tool is usually provided and installed by Semnox. It can also be downloaded from the link: http://www.wiznet.co.kr/Sub_Modules/en/product/product_detail.asp?Refid=710&page=1&cate1= &cate2=&cate3=&pid=1023&cType=2 Follow the instructions to install ‘WIZ100/105/110SR Config Tool ‘.
Turnstile Mount Reader (XCESS) – Installation & Configuration MAC of the LAN devices that are connected to the network is displayed. Select the MAC to configure Step 3: Network Configuration - Set IP configuration to ‘Static’. It is recommended to use the module in static IP mode. Set IP, Gateway, Subnet. While assigning static IP, take all necessary precautions that the same IP is not assigned to any other device in the same network. Click Setting to save the parameters. 1.
Turnstile Mount Reader (XCESS) – Installation & Configuration 2. Assign IP Address 3. Click on ‘Settings’ to save Step 4: Click on the tab ‘Serial’. Verify if the values as shown in below reference image.
Turnstile Mount Reader (XCESS) – Installation & Configuration Step 5: Click on the tab, ‘Option’. - Set Inactivity Time = 10 seconds Time = 200 ms Size = 32 Bytes Char = 0 Click on ‘Setting’ to save the changes.
Turnstile Mount Reader (XCESS) – Installation & Configuration Management Studio Settings MAC of the LAN interface board needs to be setup in Management Studio. This is setup in Parafait Management Studio > Games > Machines. 1. Enter the MAC of the LAN interface board against the machine name 2. TCP Port = 5000 3.
Turnstile Mount Reader (XCESS) – Installation & Configuration Reader Settings in Server After installing the readers, all the readers should be entered in server. Each reader has a unique number called MAC Address. A sticker with MAC address is stuck on each reader. Make a note of MAC address of all the reads with name of games. Follow this procedure to enter the MAC address of the reader in server.
Turnstile Mount Reader (XCESS) – Installation & Configuration FCC Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.