NF02500-1.0 All rights reserved to SEIKAKU. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Copyright c 2006 SEIKAKU GROUP No.1, Lane 17, Sec. 2, Han Shi West Road, Taichung, 401 TAIWAN Tel:886-4-22313737 Fax:886-4-22346757 http://www.show-pa.com e-mail: sekaku@sekaku.
All rights reserved to SHOW. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Please read this manual carefully before operating this unit for the first time.
Unplug this apparatus during lightning storms or when unused for long periods of time. Power Supply Ensure the source voltage matches the voltage of the power supply before turning ON the apparatus. WARNING CAUTION: Describes precautions that should be observed to prevent danger of the apparatus. Disposing of this product should not be placed in municipal waste and should be separate collection.
Don't use solvents such as benzol, alcohol, or other fluids with very strong volatility and flammability for cleaning the apparatus body. Clean only with dry cloth. When the apparatus needs a cleaning, you can blow off dust from the apparatus with a blower or clean with rag etc. Cleaning Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. A polarized plug has two blades with one wider than the other.
19 12 824.525 824.725 824.925 825.125 825.325 825.525 825.725 825.925 826.125 826.325 826.525 826.725 11 822.125 822.325 822.525 822.725 822.925 823.125 823.325 823.525 823.725 823.925 824.125 824.325 10 819.725 819.925 820.125 820.325 820.525 820.725 820.925 821.125 821.325 821.525 821.725 821.925 9 817.325 817.525 817.725 817.925 818.125 818.325 818.525 818.725 818.925 819.125 819.325 819.525 8 814.925 815.125 815.325 815.525 815.725 815.925 816.125 816.325 816.525 816.725 816.925 817.125 7 812.
Dynamic(S-100) Dynamic(S-600) Dynamic(S-500) Condenser(C-100) Condenser(C-200) Model No. UP-81H UP-83H UP-86H UP-87CH UP-88CH 1 Capsule UP-8H series Handheld Transmitter To well satisfy the different applications , there are 5 models in total are included in this product range, please make sure that the proper microphone has been selected for your typical sound reinforcement system before installation.
518.325 519.525 520.725 521.925 525.525 526.725 527.925 529.125 530.325 531.525 518.125 519.325 520.525 521.725 522.925 524.125 525.325 526.525 527.725 2 3 4 5 6 7 8 9 10 528.925 11 530.125 12 531.325 529.325 530.525 531.725 525.725 526.925 528.125 523.325 524.525 519.725 520.925 522.125 518.525 Group3 579.725 580.925 582.125 578.325 579.525 580.725 581.925 583.125 584.325 585.525 578.125 579.325 580.525 581.725 6 7 8 9 10 582.925 11 584.125 12 585.325 4 5 17 583.325 584.
C-100 Type: Condenser Mic. Frequency response: 50Hz~15kHz( 3dB) Impedance: 270 20% at 1kHz Sensitivity: -71dB 3dB Direction: Omni-directional S-500 Type: Dynamic Mic. Frequency response: 90Hz~12kHz( 3dB) Impedance: 680 20% at 1kHz Sensitivity: -52dB 3dB Direction: Uni-directional 3 Group2 470.325 471.525 472.725 473.925 475.125 476.325 477.525 478.725 479.925 481.125 482.325 483.525 Group1 470.125 471.325 472.525 473.725 474.925 476.125 477.325 478.525 479.725 480.925 482.125 483.
) 35KHz Max. Deviation Weight Dimensions Mic. Capsule(optional) Optional 0.246Kg 15 0.009Kg Condenser or Dynamic Capsule Condenser or Dynamic Capsule 277 36.5mm (10.9" 1.44") 97mm 68mm 22mm(3.82" 2.68" 0.87") "AA" type 2 Nickel hydrogen battery +charger 100mA Current drain Battery 30-33 KHz Tone frequency Dynamic 100dB FM (F3E) 5-50mW(adjustable 3 bands) ~ 50 1KHz<0.8% 0.
3 5 1 Power Switch It switches on/off UR-81DR main power. 2 2 THE FRONT PANEL 3.1 UR-81DR, PLL UHF Diversity Receiver 3.
13 Remark: some frequencies should be scanned manually by adjusting UP/DOWN Key, please refer to use's manual of UR-81DR for details! 1) Auto Scan Turn on the receiver, press the MEM key for a few seconds to enter into the auto scan mode. You can see"SCAN" flashes on the top left of the LCD, it means the auto scan function has been activated. under the auto scan mode, the scan function automatically searches the receiver's entire frequency band from start to stop.
3 1 2 7 4 5 3.3 UP-8P series, Body Pack Transmitter 8 6 7 7 Antenna The antenna is integrated into the transmitter body; to get effective RF transmission, never cover the antenna with hand, etc. Connect the optional recharger(see fig) with this mini jack for battery recharging. Please make sure that it is the rechargeable batteries inside before plug the recharger with the mini charge jack. 6 Charge Jack The unit may be powered from a dry or rechargeable battery.
Fig 6 Remaining battery life Fig 7 11 Fig 8 - Turn on the unit first. - Touch the CH/ON key slightly to select the edited parameter of Channel (refer to Fig 8), then use the SELECT key to specify the proper channel. - Touch the CH/ON key slightly again to select the edited parameter of Group (refer to Fig 7), then use the SELECT key to specify the proper Group.
B Fig 1 C D G E 9 - Mute Function In mute mode, use UP/DOWN key to on/off the mute function.(fig 2: mute function off, fig 3: mute function on), press the MEM button to keep the information. Note: when the transmitter is muted, no audio signal will be send out from the receiver. Press the MENU button, "GROUP" is flashing, you can choose the right frequency group you need via the UP/ DOWN button, when the frequency group is set, please press MEN button to store the information.