R UP-8DR/8H/8P SERIES No.1, Lane 17, Sec. 2, Han Shi West Road, Taichung, 401 TAIWAN Tel:886-4-22313737 Fax:886-4-22346757 http://www.show-pa.com e-mail: sekaku@sekaku.com All rights reserved to SEIKAKU. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Copyright c 2006 SEIKAKU GROUP NF02502-1.
IMPORTANT! Please read this manual carefully before operating this unit for the first time. All rights reserved to SHOW. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden.
6.3 Certificate SAFETY RELATED SYMBOLS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The symbol is used to indicate that some hazardous live terminals are involved within this apparatus, even under the normal operating conditions. The symbol is used in the service documentation to indicate that specific component shall be only replaced by the component specified in that documentation for safety reasons. Protective grounding terminal. Alternating current /voltage. Hazardous live terminal .
instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not block any ventilation openings. No naked flame sources, such as lighted candles, should be placed on the apparatus. IMPORTANT SAFETY INSTRUCTIONS Read these instructions. Follow all instructions. Keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer.
F6: 740.000-764.000(740-769)MHz Group1 Group2 Group3 Group4 Group5 Group6 Group7 Group8 Group9 Group10 Group11 Group12 1 740.125 740.325 740.525 740.725 740.925 741.125 741.325 741.525 741.725 741.925 742.125 742.325 2 742.525 742.725 742.925 743.125 743.325 743.525 743.725 743.925 744.125 744.325 744.525 744.725 3 744.925 745.125 745.325 745.525 745.725 745.925 746.125 746.325 746.525 746.725 746.925 747.125 4 747.325 747.525 747.725 747.925 748.125 748.325 748.525 748.725 748.925 749.125 749.325 749.
F4: 638.000-662.000(638-664)MHz 1. INTRODUCTION Thanks for purchasing the SHOW wireless microphone system. The UP-8DR/8H/8P series is the delicately designed UHF, PLL synthesized system, with two antennas built inside the receiver for smart switching diversity control, the higher level RF signals may be fed into the system for greater reliability and coverage, therefore, the risks of breakdown and interference are to be effectively reduced.
F2: 518.000-542.000(518-544)MHz Group1 Group2 Group3 Group4 Group5 1 518.125 518.325 518.525 518.725 518.925 Group6 519.125 2 3 4 519.325 520.525 521.725 519.525 520.725 521.925 519.725 520.925 522.125 519.925 521.125 522.325 520.125 521.325 522.525 520.325 521.525 522.725 5 6 522.925 524.125 523.125 524.325 523.325 524.525 523.525 524.725 523.725 524.925 523.925 525.125 7 8 9 525.325 526.525 527.725 525.525 526.725 527.925 525.725 526.925 528.125 525.925 527.125 528.325 526.
6. ANNEX S-500 Type: Dynamic Mic. Frequency response: 90Hz~12kHz( 3dB) Impedance: 680 20% at 1kHz Sensitivity: -52dB 3dB Direction: Uni-directional 6.1 Frequency Band Selection Most countries closely regulate the radio frequencies used in the transmission of wireless information. These regulations state which devices can use which frequencies, and help to limit the amount of RF(radio frequency)interference in all wireless communications.
MODEL UP-8H SPECIFICATION Oscillation mode PLL UHF SYNTHESIZED Carrier frequency band UHF 470-900 MHz Frequency response Frequency stability Dependent on applicable country regulations 50 Hz-15KHz ( 3dB) 0.005% (-10 ~ 50 1KHz<0.8% Modulation mode FM (F3E) 5-50mW(adjustable 3 bands) Dynamic 100dB Tone frequency 30-33 KHz Current drain 100mA Max. Deviation Battery Optional Mic. Capsule(optional) C-200 Type: Condenser Mic.
Last but not the least, the operating frequency of this wireless system may be varied from 470MHz to 900MHz, please refer to your national EMC regulations to pick out the authorized frequency band (F1 ~ F8, detail please see Annex hereafter) for your end application. 2. FEATURES -UP-8DR, PLL UHF Diversity Receiver, 2) Manually Selecting Frequency Turn on the receiver .
Note: when the transmitter is muted, the microphone couldn't send out any AF signal, that means, no sound has been sent out from the microphone. 2 UP/DOWN key In the menu mode, you can choose the right value via these two keys. 3 Display The LCD shows RF/AF signal, remaining battery life of the transmitter, group value, channel value and the selected frequency. Fig 12 4 Menu key Via this key, you can choose the right function you want.
- RF Output Power Select 1 Massive Front Grill Extremely rugged spring steel mesh grill to protect the capsule underneath in tough stage or live performance. 2 LCD Display Generally, the LCD displays the current operation status.
1 LCD Display 4.2 For the UP-8H/8P series transmitters Generally, the LCD displays the current operation status. 4.2.1 Edit The Parameter Press and hold the CH/ON key for a few seconds, then the transmitter is powered on. Now, the LCD displays the current operation status: Preset frequency Remaining battery life 2 CH/ON Key Keep pressing this key for a few seconds, the unit will be powered on or off.
4. OPERATION 4.1 For the UP-8DR, PLL UHF Diversity Receiver Fig 2 mute function off F Fig 3 mute function on G - Output Level Adjusting A B C D E In output level adjusting mode(see fig 4), use the SELECT button to adjust the output level. The output level has 3 choices, 0 indicates the output level is 500mV, 1 indicates the output level is 300mV, 2 indicates the output level is 150mV. Note: the function is only applied to the level of Balanced output.