Description
The AT&T model number SW-ATT-TF Sensor is a fully supervised, tamper
protected sensor that will monitor ambient temperature detect a flood/no flood
condition. It reports these conditions to the Digital Life Controller. The sensor
can be configured to detect temperature only
Flood Conditionsonce the sensor detects the presence of water, the integral
transmitter will send a flood alarm transmission to the Digital Life Controller.
The sensor will also send a restore (no flood) report when the presence of
water is no longer detected by the flood sensor. For flood reporting the sensor
requires the installation of the supplied external flood probe.
Temperature Conditionsthe temperature sensor will check the ambient
temperature approximately once per minute. If the temperature has changed
by three (3) degrees F or more since the sensors last 3 degree report, the
integral transmitter will send a temperature report to the Digital Life Controller.
(Check the installation section for required wiring for the sensor if it is used in
temperature only configuration.) The temperature sensor does not send a
restore message, but does send ambient temperature approximately once
every 70 minutes as part of the supervisory transmission.
Low Batteryif the battery voltage falls below a prescribed voltage level, the
integral transmitter will a low battery report to the Digital Life Controller
whenever transmitting. (See the ―Changing the Battery‖ section of these
instructions for information about changing the battery.)
Flood Probe Fault- if at any time the sensor detects that the wiring between
the sensor and the flood probe is either open circuit (wire cut or missing) or
short circuit (e.g. installation staple cutting into wires), the sensor will transmit
―sensor trouble‖ multiple times or until the fault is corrected.
Installing the Battery
When the system indicates the sensor battery is low, replace it immediately.
Use the recommended replacement batteries (See specification) or contact
AT&T technical support for more information.